BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES

被引:86
|
作者
DESCHEERDER, IK
WILCZEK, KL
VERBEKEN, EV
VANDORPE, J
LAN, PN
SCHACHT, E
DEGEEST, H
PIESSENS, J
机构
[1] UNIV HOSP GASTHUISBERG,DEPT PATHOL,B-3000 LOUVAIN,BELGIUM
[2] DEPT ORGAN CHEM,BIOMAT RES GRP,GHENT,BELGIUM
关键词
STENTS; POLYMER; BIOCOMPATIBILITY; THROMBOGENICITY; NEOINTIMAL RESPONSE;
D O I
10.1016/0021-9150(94)05472-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Polymer coatings have been suggested to decrease the thrombogenicity of metallic intravascular stents. The purpose of the present study was to investigate the intimal response to two different polymers when used as coatings for stents implanted in normal porcine coronary arteries. Non-articulated stainless steel-slotted tube stents were coated with either a biodegradable poly(organo)phosphazene with amino-acid ester side groups or a biostable polyurethane prepared from an amphiphilic polyether, dephenylmethane-4,4'-diisocyanate and butane diol as chain extender. In order to induce vascular wall injury, the stents were deployed using an oversized balloon. At 6 weeks follow-up, the angiographic luminal diameter measured in four polyurethane-coated stents and in six bare metallic stents was similar and 20% less than immediately post-stenting. However, in four polyphosphazene-coated stents the difference was 65% (P = 0.01 when compared to bare metal). At post-mortem morphometry the degree of luminal area stenosis was also similar in polyurethane-coated and in bare metallic stents (32 +/- 7.6% vs. 39 +/- 14%, NS) but reached 81 +/- 19% in polyphosphazene-coated stents (P < 0.03 when compared to bare metal). Thus, poly(organo)phosphazene induced a more pronounced histiolymphocytic and fibromuscular reaction than amphiphilic polyurethane, which appeared to be promising as biocompatible stent coating and, consequently, as a potential carrier for vasoactive drugs.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 50 条
  • [21] Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries
    Buszman, Pawel
    Milewski, Krzysztof
    Zurakowski, Aleksander
    Pajak, Jacek
    Liszka, Lukasz
    Buszman, Piotr
    Musiol, Ewa
    AbuSamra, Motaz
    Trznadel, Stanislaw
    Kaluza, Grzegorz
    KARDIOLOGIA POLSKA, 2010, 68 (05) : 503 - 509
  • [22] Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries
    Hardhammar, PA
    vanBeusekom, HMM
    Emanuelsson, HU
    Hofma, SH
    Albertsson, PA
    Verdouw, PD
    Boersma, E
    Serruys, PW
    vanderGiessen, WJ
    CIRCULATION, 1996, 93 (03) : 423 - 430
  • [23] Implantation of metal phosphorylcholine coated stents in rabbit iliac and porcine coronary arteries
    Kuiper, KKJ
    Robinson, KA
    Chronos, NAF
    Nordrehaug, JE
    CIRCULATION, 1997, 96 (08) : 1607 - 1607
  • [24] Comparison of self-expanding polyethylene terephthalate and metallic stents implanted in porcine iliac arteries
    Wilczek, K
    DeScheerder, I
    Wang, K
    Verbeken, E
    Piessens, J
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1996, 19 (03) : 176 - 180
  • [25] Carbon-coated stents implanted in porcine iliac and renal arteries: Histologic and histomorphometric study
    Galloni, M
    Prunotto, M
    Santarelli, A
    Laborde, F
    Dibie, A
    Isaia, C
    Monari, E
    Gatti, AM
    Pasquino, E
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (08) : 1053 - 1061
  • [26] Biocompatibility, safety and efficacy of polymer-free, drug eluting stents employing microporous ultra-thin hydroxyapatite stent coating in normal porcine coronary arteries
    Kaluza, Greg L.
    Rajtar, Arc W.
    Schulz, Daryl G.
    Granada, Juan F.
    Smith, Doug
    Lien, Maurice
    Tsui, Manus
    Liu, Dean-Mo
    Hakimi, Dorna
    Yang, Quanzu
    Tsvetkov, Alex
    Budzynski, Vlad
    Tio, Fermin O.
    Troczynski, Tom
    Raizner, Albert E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 133M - 133M
  • [27] Bare Metal Stents on Resveratrol-Coated Balloons in Porcine Coronary and Peripheral Arteries
    Kamann, Stefanie
    Haase, Tobias
    Stolzenburg, Nicola
    Loechel, Melanie
    Peters-Berg, Daniel
    Schuett, Denise
    Schnorr, Joerg
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (23)
  • [28] Effect of stents coated by an autologous vein graft on intimal hyperplasia in porcine coronary arteries
    Toutouzas, K
    Stefanadis, C
    Tsiamis, E
    Vlachopoulos, C
    Vaina, S
    Tsekoura, D
    Haldi, L
    Kostomitsopoulos, N
    Toutouzas, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 414A - 414A
  • [29] Long-Term Effects of Novel Biodegradable, Polymer-Coated, Sirolimus-Eluting Stents on Neointimal Formation in a Porcine Coronary Model
    Peng, Hong-Yu
    Chen, Ming
    Zheng, Bo
    Wang, Xin-Gang
    Huo, Yong
    INTERNATIONAL HEART JOURNAL, 2009, 50 (06) : 811 - 822
  • [30] NEOINTIMAL HYPERPLASIA WITHIN 3 DIFFERENT STENTS AFTER IMPLANTATION IN NORMAL CORONARY-ARTERIES OF PIGS
    VANDERGIESSEN, WJ
    STRAUSS, BH
    VANBEUSEKOM, HMM
    VANWOERKENS, LJ
    VERDOUW, PD
    SERRUYS, PW
    CIRCULATION, 1990, 82 (04) : 315 - 315