BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES

被引:86
|
作者
DESCHEERDER, IK
WILCZEK, KL
VERBEKEN, EV
VANDORPE, J
LAN, PN
SCHACHT, E
DEGEEST, H
PIESSENS, J
机构
[1] UNIV HOSP GASTHUISBERG,DEPT PATHOL,B-3000 LOUVAIN,BELGIUM
[2] DEPT ORGAN CHEM,BIOMAT RES GRP,GHENT,BELGIUM
关键词
STENTS; POLYMER; BIOCOMPATIBILITY; THROMBOGENICITY; NEOINTIMAL RESPONSE;
D O I
10.1016/0021-9150(94)05472-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Polymer coatings have been suggested to decrease the thrombogenicity of metallic intravascular stents. The purpose of the present study was to investigate the intimal response to two different polymers when used as coatings for stents implanted in normal porcine coronary arteries. Non-articulated stainless steel-slotted tube stents were coated with either a biodegradable poly(organo)phosphazene with amino-acid ester side groups or a biostable polyurethane prepared from an amphiphilic polyether, dephenylmethane-4,4'-diisocyanate and butane diol as chain extender. In order to induce vascular wall injury, the stents were deployed using an oversized balloon. At 6 weeks follow-up, the angiographic luminal diameter measured in four polyurethane-coated stents and in six bare metallic stents was similar and 20% less than immediately post-stenting. However, in four polyphosphazene-coated stents the difference was 65% (P = 0.01 when compared to bare metal). At post-mortem morphometry the degree of luminal area stenosis was also similar in polyurethane-coated and in bare metallic stents (32 +/- 7.6% vs. 39 +/- 14%, NS) but reached 81 +/- 19% in polyphosphazene-coated stents (P < 0.03 when compared to bare metal). Thus, poly(organo)phosphazene induced a more pronounced histiolymphocytic and fibromuscular reaction than amphiphilic polyurethane, which appeared to be promising as biocompatible stent coating and, consequently, as a potential carrier for vasoactive drugs.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 50 条
  • [31] Use of nitric-oxide-eluting polymer-coated coronary stents for prevention of restenosis in pigs
    Buergler, JM
    Tio, FO
    Schulz, DG
    Khan, MM
    Mazur, W
    French, BA
    Raizner, AE
    Ali, NM
    CORONARY ARTERY DISEASE, 2000, 11 (04) : 351 - 357
  • [32] Efficacy and safety of absorbable metallic stents with adjunct intracoronary beta radiation in porcine coronary arteries
    Waksman, Ron
    Pakala, Rajbabu
    Okabe, Teruo
    Baffour, Richard
    Seabron, Rufus
    Hellinga, David
    Tio, Fermin O.
    Wittchow, Eric
    Hartwig, Sonja
    Waldmann, Karl-Heinz
    Harder, Claus
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 19B - 19B
  • [33] Sustained inhibition of neointimal hyperplasia after implanting novel biodegradable polymer-coated emodin-eluting stents in the porcine coronary model.
    Ge, J
    Liu, X
    Wang, KQ
    Qian, J
    Wang, X
    Jia, J
    Zhao, Y
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 151E - 152E
  • [34] Intense Inflammatory Reaction to Heparin Polymer Coated Intravascular Palmaz Stents in Porcine Arteries Compared to Uncoated Palmaz Stents
    Scott C. Goodwin
    Hyo-Chun Yoon
    Gary Chen
    Peter Abdel-Sayed
    Mary M. Costantino
    Sheila M. Bonilla
    Earl Nishimura
    CardioVascular and Interventional Radiology, 2003, 26 : 158 - 167
  • [35] Biocompatibility of a novel ultra-thin hydroxyapatite stent coating in normal porcine coronary arteries
    Kaluza, GL
    Clubb, FJ
    Schulz, DG
    Granada, JF
    Smith, D
    Lien, M
    Troczynski, T
    Rajtar, AW
    Raizner, AE
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 7H - 7H
  • [36] In-Vivo Acute Expansion of Bioresorbable Scaffolds and Metallic Stents in Normal Porcine Coronary Arteries: A Critical Appraisal of Compliance Chart Accuracy
    Isaza, Nicolas
    Ferrone, Marco
    Melnick, Gilberto
    Cheng, Yanping
    Conditt, Gerard
    Granada, Juan
    Kaluza, Grzegorz
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B129 - B129
  • [37] Vascular response and mechanical integrity of the new biodegradable polymer coated sirolimus-eluting PROLIM stent implanted in porcine coronary arteries
    Milewski, Krzysztof
    Gorycki, Bogdan
    Buszman, Piotr P.
    Jelonek, Michal
    Beaudry, Diane
    Lapointe, Jean-Martin
    Guy, Louis-Georges
    Abusamra, Motaz
    Pajak, Jacek
    Kinasz, Wojciech
    Wojakowski, Wojciech
    Leclerc, Guy
    Gil, Robert J.
    Buszman, Pawel E.
    KARDIOLOGIA POLSKA, 2012, 70 (07) : 703 - 711
  • [38] Drug Release from a Chemically-Anchored PEG/Phospholipid Monolayer onto Polymer-Coated Metallic Stents
    Krishna, Ohm Divyam
    Jeon, Ok Cheol
    Kim, Kwangmeyung
    Byun, Youngro
    Moon, Hyun Tae
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2010, 21 (6-7) : 789 - 802
  • [39] Local angiopeptin delivery using coated stents reduces neointimal proliferation in overstretched porcine coronary arteries
    DeScheerder, I
    Wilczek, K
    VanDorpe, J
    Verbeken, E
    Cathapermal, S
    Wang, K
    Desmet, W
    Schacht, E
    Foegh, M
    DeGeest, H
    Piessens, J
    JOURNAL OF INVASIVE CARDIOLOGY, 1996, 8 (05): : 215 - 222
  • [40] EFFECT OF CANDESARTAN WITH PIOGLITAZONE ON CORONARY ENDOTHELIAL FUNCTION AND VASCULAR INFLAMMATION IN PORCINE CORONARY ARTERIES IMPLANTED WITH SIROLIMUS-ELUTING STENTS
    Dohi, Tomotaka
    Miyauchi, Katsumi
    Tsuruta, Ryo
    Kubota, Naozumi
    Kasai, Takatoshi
    Iesaki, Takhumi
    Daida, Hiroyuki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)