Biocompatibility of tetramethylpyrazine-eluting stents in normal porcine coronary arteries

被引:0
|
作者
Ma Gen-Shan [1 ]
Chen Li-Juan [1 ]
Chen Zhong [1 ]
Ding Shu [1 ]
Shen Cheng-Xing [1 ]
Feng Yi [1 ]
机构
[1] Southeast Univ, Zhongda Hosp, Dept Cardiol, Nanjing 210009, Peoples R China
关键词
tetramethylpyrazine-eluting stent (TES); biocompatibility; porcine coronary artery;
D O I
10.1016/j.biopha.2007.07.008
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: Drug-eluting stents have been used to markedly decrease in-stent restenosis in 6 months, but they are noticed due to the late thrombogenicity. The purpose of the present study was to evaluate the biocompatibility of Tetramethylpyrazine-eluting stents by investigating the intimal response and thrombogenicity in normal porcine coronary arteries by quantitative coronary angiography (QCA), intravascular ultrasound (IVUS) and histomorphometry. Methods: Bare metal stents (BMS) were uniformly spray-coated with Tetramethylpyrazine (TMP 200 mu g) and prepared for TMP-eluting stents (TES). Fourteen coronary arteries in 14 pigs underwent stent implantation. Seven TES were implanted in 7 pigs and 7 BMS in other 7 pigs. The stents were deployed with a stent-to-artery ratio of 1.1-1.2/1.0 in order to induce vascular wall injury. QCA and IVUS were performed before and immediately after the implantations and at 28 days (end time point). The analysis on blood cell count, biochemical parameters, status of behavior of pigs were evaluated before the implantation and at the time of I and 28 days. Stented-coronary arteries, stented-coronary arteries related ventricular wall, lung, liver and kidney were harvested after euthanasia of animals at the endpoint. Histopathology and histomorphometry had been done to assess the local toxicity of TES to these organs. Results: All the stents were successfully implanted, however, 4 pigs died of cardiac tamponade or anesthesia. No bone marrow depression and hemolysis was seen. No damage to the function and metabolism of liver and kidney was discovered. No thrombosis was found in control and test groups. Few inflammatory cells were found in the stented-coronary artery walls at each endpoint in both groups. No damage to stented-coronary arteries related ventricular wall, lung, liver and kidney was detected due to TES implantation. Compared with the control group, the neointimal area was significantly reduced in the TES group (60.2 +/- 23.5% vs 10.0 +/- 2.1%, P = 0.01) by IVUS analysis, but the lumen area in the TES group was increased (4.34 +/- 0.93 mm(2) vs 1.29 +/- 1.02 mm(2), p = 0.011), the neointimal area was reduced markedly (1.51 +/- 0.45 mm(2) vs 4.60 +/- 1.39 mm(2), P = 0.004). Conclusions: The biocompatibility of TES in porcine model at 28 days seems to be good and acceptable. Biocompatibility can be evaluated by IVUS and histopathology in a porcine restenosis model. (c) 2007 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [1] Inhibition of neointima formation by tetramethylpyrazine-eluting stents in porcine coronary arteries
    Chen, L. J.
    Ma, G. S.
    Shen, C. X.
    Chen, Z.
    Feng, Y.
    Ding, S.
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (8B): : 8C - 8C
  • [2] Tetramethylpyrazine-eluting stents prevented in-stent restenosis in a porcine model
    Ma, Genshan
    Ding, Shu
    Feng, Yi
    Shen, Chengxing
    Chen, Lijuan
    Chen, Zhong
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 2007, 50 (02) : 201 - 205
  • [3] Biocompatibility of phosphorylcholine coated stents in normal porcine coronary arteries
    Whelan, DM
    van der Giessen, WJ
    Krabbendam, SC
    van Vliet, EA
    Verdouw, PD
    Serruys, PW
    van Beusekom, HMM
    HEART, 2000, 83 (03) : 338 - 345
  • [4] Short-Term Effect of Tetramethylpyrazine-Eluting Stents on Neointimal Hyperplasia in Renal Arteries.
    Chen, Long
    Chen, Zhong
    Ding, Zhen
    Fan, Liuzhang
    Ma, Genshan
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 138S - 138S
  • [5] BIOCOMPATIBILITY OF POLYMER-COATED OVERSIZED METALLIC STENTS IMPLANTED IN NORMAL PORCINE CORONARY-ARTERIES
    DESCHEERDER, IK
    WILCZEK, KL
    VERBEKEN, EV
    VANDORPE, J
    LAN, PN
    SCHACHT, E
    DEGEEST, H
    PIESSENS, J
    ATHEROSCLEROSIS, 1995, 114 (01) : 105 - 114
  • [6] Biodegradable polymer coated, paclitaxel eluting stents in the porcine coronary arteries
    Milewski, K
    Buszman, P
    Zurakowski, A
    Pajak, J
    Stojko, J
    Abu Samra, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 23H - 23H
  • [7] Efficacy and safety of pimecrolimus-eluting stents in porcine coronary arteries
    Waksman, Ron
    Pakala, Rajbabu
    Baffour, Richard
    Hellinga, David
    Seabron, Rufus
    Tio, Fermin O.
    Wittchow, Eric
    Tittelbach, Michael
    Diener, Tobias
    Harder, Claus
    Virmani, Renu
    Jones, Russel
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2007, 8 (04) : 259 - 274
  • [8] Efficacy and safety of pimecrolimus-eluting stents in porcine coronary arteries
    Waksman, Ron
    Pakala, Rajbabu
    Balfour, Richard
    Seabron, Rufus
    Hellinga, David
    Tio, Fermin O.
    Wittchow, Eric
    Hartwig, Sonja
    Tittelbach, Michael
    Harder, Claus
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 17B - 17B
  • [9] Biocompatibility, safety and efficacy of polymer-free, drug eluting stents employing microporous ultra-thin hydroxyapatite stent coating in normal porcine coronary arteries
    Kaluza, Greg L.
    Rajtar, Arc W.
    Schulz, Daryl G.
    Granada, Juan F.
    Smith, Doug
    Lien, Maurice
    Tsui, Manus
    Liu, Dean-Mo
    Hakimi, Dorna
    Yang, Quanzu
    Tsvetkov, Alex
    Budzynski, Vlad
    Tio, Fermin O.
    Troczynski, Tom
    Raizner, Albert E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 133M - 133M
  • [10] Abnormal Vasomotor Function of Porcine Coronary Arteries Distal to Sirolimus-Eluting Stents
    Li, Jinsheng
    Jabara, Refat
    Pendyala, Lakshmana
    Otsuka, Yoritaka
    Shinke, Toshiro
    Hou, Dongming
    Robinson, Keith
    Chronos, Nicolas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) : 279 - 285