Biocompatibility of tetramethylpyrazine-eluting stents in normal porcine coronary arteries

被引:0
|
作者
Ma Gen-Shan [1 ]
Chen Li-Juan [1 ]
Chen Zhong [1 ]
Ding Shu [1 ]
Shen Cheng-Xing [1 ]
Feng Yi [1 ]
机构
[1] Southeast Univ, Zhongda Hosp, Dept Cardiol, Nanjing 210009, Peoples R China
关键词
tetramethylpyrazine-eluting stent (TES); biocompatibility; porcine coronary artery;
D O I
10.1016/j.biopha.2007.07.008
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: Drug-eluting stents have been used to markedly decrease in-stent restenosis in 6 months, but they are noticed due to the late thrombogenicity. The purpose of the present study was to evaluate the biocompatibility of Tetramethylpyrazine-eluting stents by investigating the intimal response and thrombogenicity in normal porcine coronary arteries by quantitative coronary angiography (QCA), intravascular ultrasound (IVUS) and histomorphometry. Methods: Bare metal stents (BMS) were uniformly spray-coated with Tetramethylpyrazine (TMP 200 mu g) and prepared for TMP-eluting stents (TES). Fourteen coronary arteries in 14 pigs underwent stent implantation. Seven TES were implanted in 7 pigs and 7 BMS in other 7 pigs. The stents were deployed with a stent-to-artery ratio of 1.1-1.2/1.0 in order to induce vascular wall injury. QCA and IVUS were performed before and immediately after the implantations and at 28 days (end time point). The analysis on blood cell count, biochemical parameters, status of behavior of pigs were evaluated before the implantation and at the time of I and 28 days. Stented-coronary arteries, stented-coronary arteries related ventricular wall, lung, liver and kidney were harvested after euthanasia of animals at the endpoint. Histopathology and histomorphometry had been done to assess the local toxicity of TES to these organs. Results: All the stents were successfully implanted, however, 4 pigs died of cardiac tamponade or anesthesia. No bone marrow depression and hemolysis was seen. No damage to the function and metabolism of liver and kidney was discovered. No thrombosis was found in control and test groups. Few inflammatory cells were found in the stented-coronary artery walls at each endpoint in both groups. No damage to stented-coronary arteries related ventricular wall, lung, liver and kidney was detected due to TES implantation. Compared with the control group, the neointimal area was significantly reduced in the TES group (60.2 +/- 23.5% vs 10.0 +/- 2.1%, P = 0.01) by IVUS analysis, but the lumen area in the TES group was increased (4.34 +/- 0.93 mm(2) vs 1.29 +/- 1.02 mm(2), p = 0.011), the neointimal area was reduced markedly (1.51 +/- 0.45 mm(2) vs 4.60 +/- 1.39 mm(2), P = 0.004). Conclusions: The biocompatibility of TES in porcine model at 28 days seems to be good and acceptable. Biocompatibility can be evaluated by IVUS and histopathology in a porcine restenosis model. (c) 2007 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [31] BIOCOMPATIBILITY OF A NOVEL NON-DRUG ELUTING BIOABSORBABLE STENT IN PORCINE CORONARY ARTERIES: AN OPTICAL COHERENCE TOMOGRAPHY AND HISTOLOGY STUDY
    Gongora, Carlos A.
    Tellez, Armando
    Ramzipoor, Kamal
    Chang, Lee
    Cheng, Yanping
    Peppas, Athanasios
    Shibuya, Masahiko
    Narvaez, Jose
    Rousselle, Serge
    Kaluza, Greg
    Estrada, Edward A.
    Granada, Juan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1887 - A1887
  • [32] Drug Eluting Stents versus Bare Metal Stents in Large Coronary Arteries During Primary Percutaneous Coronary Intervention
    Graham, Adam
    Akhtar, Mohammed M.
    Jones, Daniel
    Rathod, Krishna
    Gallagher, S.
    Jain, Ajay
    Mohiddin, Sam
    Knight, Charles
    Mathur, Anthony
    Wragg, Andrew
    CIRCULATION, 2011, 124 (21)
  • [33] Candesartan With Pioglitazone Protects Against Endothelial Dysfunction and Inflammatory Responses in Porcine Coronary Arteries Implanted With Sirolimus-Eluting Stents
    Dohi, Tomotaka
    Miyauchi, Katsumi
    Iesaki, Takafumi
    Tsuruta, Ryo
    Tsuboi, Shuta
    Ogita, Manabu
    Kubota, Naozumi
    Kasai, Takatoshi
    Yokoyama, Takayuki
    Daida, Hiroyuki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1098 - 1106
  • [34] In vitro and in vivo degradation of rapamycin-eluting Mg-Nd-Zn-Zr alloy stents in porcine coronary arteries
    Shi, Yongjuan
    Zhang, Lei
    Chen, Jiahui
    Zhang, Jian
    Yuan, Feng
    Shen, Li
    Chen, Chenxin
    Pei, Jia
    Li, Zhonghua
    Tan, Jinyun
    Yuan, Guangyin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 80 : 1 - 6
  • [35] Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries
    Waksman, Ron
    Pakala, Rajbabu
    Kuchulakanti, Pramod K.
    Baffour, Richard
    Hellinga, David
    Seabron, Rufus
    Tio, Fermin O.
    Wittchow, Eric
    Hartwig, Sonja
    Harder, Claus
    Rohde, Roland
    Heublein, Bernd
    Andreae, Arnim
    Waldmann, Karl-Heinz
    Haverich, Axel
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (04) : 607 - 617
  • [36] Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries
    Hardhammar, PA
    vanBeusekom, HMM
    Emanuelsson, HU
    Hofma, SH
    Albertsson, PA
    Verdouw, PD
    Boersma, E
    Serruys, PW
    vanderGiessen, WJ
    CIRCULATION, 1996, 93 (03) : 423 - 430
  • [37] Phosphorylcholine coated stents: Angiographic and morphometric assessment in porcine coronary arteries
    Malik, N
    Gunn, J
    Newman, C
    Crossman, DC
    Cumberland, DC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 414A - 414A
  • [38] Drug-eluting stents accelerate atherosclerosis at the sites of stented coronary arteries
    Nakazawa, G.
    Ladich, E.
    Finn, A. V.
    Mont, E. K.
    Burke, A. P.
    Kolodgie, F. D.
    Virmani, R.
    EUROPEAN HEART JOURNAL, 2008, 29 : 777 - 777
  • [39] Drug-Eluting or Bare-Metal Stents in Large Coronary Arteries
    van Bemmel, Marnix W.
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (12): : 1179 - 1179
  • [40] Formulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology Efficient Nano-Drug Delivery via Bioabsorbable Polymeric Nanoparticle-Eluting Stents in Porcine Coronary Arteries
    Nakano, Kaku
    Egashira, Kensuke
    Masuda, Seigo
    Funakoshi, Kouta
    Zhao, Gang
    Kimura, Satoshi
    Matoba, Tetsuya
    Sueishi, Katsuo
    Endo, Yasuhisa
    Kawashima, Yoshiaki
    Hara, Kaori
    Tsujimoto, Hiroyuki
    Tominaga, Ryuji
    Sunagawa, Kenji
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) : 277 - 283