Biocompatibility of tetramethylpyrazine-eluting stents in normal porcine coronary arteries

被引:0
|
作者
Ma Gen-Shan [1 ]
Chen Li-Juan [1 ]
Chen Zhong [1 ]
Ding Shu [1 ]
Shen Cheng-Xing [1 ]
Feng Yi [1 ]
机构
[1] Southeast Univ, Zhongda Hosp, Dept Cardiol, Nanjing 210009, Peoples R China
关键词
tetramethylpyrazine-eluting stent (TES); biocompatibility; porcine coronary artery;
D O I
10.1016/j.biopha.2007.07.008
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: Drug-eluting stents have been used to markedly decrease in-stent restenosis in 6 months, but they are noticed due to the late thrombogenicity. The purpose of the present study was to evaluate the biocompatibility of Tetramethylpyrazine-eluting stents by investigating the intimal response and thrombogenicity in normal porcine coronary arteries by quantitative coronary angiography (QCA), intravascular ultrasound (IVUS) and histomorphometry. Methods: Bare metal stents (BMS) were uniformly spray-coated with Tetramethylpyrazine (TMP 200 mu g) and prepared for TMP-eluting stents (TES). Fourteen coronary arteries in 14 pigs underwent stent implantation. Seven TES were implanted in 7 pigs and 7 BMS in other 7 pigs. The stents were deployed with a stent-to-artery ratio of 1.1-1.2/1.0 in order to induce vascular wall injury. QCA and IVUS were performed before and immediately after the implantations and at 28 days (end time point). The analysis on blood cell count, biochemical parameters, status of behavior of pigs were evaluated before the implantation and at the time of I and 28 days. Stented-coronary arteries, stented-coronary arteries related ventricular wall, lung, liver and kidney were harvested after euthanasia of animals at the endpoint. Histopathology and histomorphometry had been done to assess the local toxicity of TES to these organs. Results: All the stents were successfully implanted, however, 4 pigs died of cardiac tamponade or anesthesia. No bone marrow depression and hemolysis was seen. No damage to the function and metabolism of liver and kidney was discovered. No thrombosis was found in control and test groups. Few inflammatory cells were found in the stented-coronary artery walls at each endpoint in both groups. No damage to stented-coronary arteries related ventricular wall, lung, liver and kidney was detected due to TES implantation. Compared with the control group, the neointimal area was significantly reduced in the TES group (60.2 +/- 23.5% vs 10.0 +/- 2.1%, P = 0.01) by IVUS analysis, but the lumen area in the TES group was increased (4.34 +/- 0.93 mm(2) vs 1.29 +/- 1.02 mm(2), p = 0.011), the neointimal area was reduced markedly (1.51 +/- 0.45 mm(2) vs 4.60 +/- 1.39 mm(2), P = 0.004). Conclusions: The biocompatibility of TES in porcine model at 28 days seems to be good and acceptable. Biocompatibility can be evaluated by IVUS and histopathology in a porcine restenosis model. (c) 2007 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [41] PERCUTANEOUS POLYMERIC STENTS IN PORCINE CORONARY-ARTERIES - INITIAL EXPERIENCE WITH POLYETHYLENE TEREPHTHALATE STENTS
    MURPHY, JG
    SCHWARTZ, RS
    EDWARDS, WD
    CAMRUD, AR
    VLIESTRA, RE
    HOLMES, DR
    CIRCULATION, 1992, 86 (05) : 1596 - 1604
  • [42] INTRAARTERIAL BIOCOMPATIBILITY OF POLYETHYLENE TEREPHTHALATE SELF-EXPANDABLE STENTS IMPLANTED IN PORCINE PERIPHERAL ARTERIES
    DESCHEERDER, IK
    WILCZEK, KV
    VERBEKEN, EV
    BARIOS, L
    PIESSENS, J
    DEGEEST, H
    ACADEMIC RADIOLOGY, 1995, 2 (02) : 154 - 158
  • [43] Safety and Feasibility of Sirolimus Eluting Bioresorbable Stents in Porcine Renal Arteries-90-Day Angiographic and OCT study in Normal Swine
    Furer, Ariel
    Gasior, Pawel
    McGregor, Jenn
    Palmieri, Taylor
    Conditt, Gerard
    Granada, Juan
    Kaluza, Greg
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B341 - B341
  • [44] Drug eluting coronary stents
    Boden, Mark
    Richard, Robert
    Schwarz, Marlene
    Strickler, Fred
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 234
  • [45] MICROARRAY GENE EXPRESSION PROFILING IDENTIFIES PATHOPHYSIOLOGICAL VASCULAR RESPONSES TO IMPLANTATION OF OVERLAPPING DRUG-ELUTING STENTS INTO PORCINE CORONARY ARTERIES
    Chen, Jing
    Huang, Andrew
    Nakamura, Takamitsu
    Matyunina, Lilya
    Yu, Jianing
    Li, Jinsheng
    Singh, Jaipal
    McDonald, John F.
    Chronos, Nicolas
    Hou, Dongming
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1693 - E1693
  • [46] Negative vascular remodelling after implantation of bioabsorbable magnesium alloy stents in porcine coronary arteries: a randomised comparison with bare-metal and sirolimus-eluting stents
    Maeng, M.
    Jensen, L. O.
    Falk, E.
    Andersen, H. R.
    Thuesen, L.
    HEART, 2009, 95 (03) : 241 - 246
  • [47] Local drug delivery of paclitaxel-eluting balloon in porcine coronary arteries
    Gyoengyoesi, M.
    Posa, A.
    Hemetsberger, R.
    Petnehazy, O.
    Petrasi, Z.
    Glogar, D.
    EUROPEAN HEART JOURNAL, 2008, 29 : 687 - 688
  • [48] Comparison of clinical outcomes of implantation of drug-eluting stents with bare metal stents in large coronary arteries
    Mishra, S
    Wolfram, RM
    Xue, ZY
    Gevorkian, N
    Pichard, AD
    Satler, LF
    Suddath, W
    Kent, K
    Waksman, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 46B - 47B
  • [49] Short-term effects of biocorrodible iron stents in porcine coronary arteries
    Waksman, Ron
    Pakala, Rajbabu
    Baffour, Richard
    Seabron, Rufus
    Hellinga, David
    Tio, Fermin O.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2008, 21 (01) : 15 - 20
  • [50] Cypher versus Taxus stents: Comparing inflammatory response in porcine coronary arteries
    Schwartz, Robert S.
    Wilson, Gregory J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 36M - 36M