Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer

被引:6
|
作者
Bayhan, Cihangul [1 ]
Ozsurekci, Yasemin [1 ]
Tekcam, Necmiye [1 ]
Guloglu, Ayse [1 ]
Ehliz, Gulten [1 ]
Ceyhan, Mehmet [1 ]
Kara, Ates [1 ]
机构
[1] Hacettepe Univ, Tip Fak, Cocuk Enfeksiyon Hastaliklari Bilim Dali, Ankara, Turkey
来源
JOURNAL OF PEDIATRIC INFECTION | 2014年 / 8卷 / 02期
关键词
Fever; infrared; thermometer;
D O I
10.5152/ced.2014.1698
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective: Non-contact infrared thermometer NCIT) is a quick, non-invasive, and easy-to-use method to measure body temperature, not requiring sterilization. We aimed to evaluate the reliability of NCIT in the first assessment of patients in a hospital. Material and Methods: The study was carried out in Hacettepe University Ihsan Dogramaci Children's Hospital between August and September 2013 with patients older than 4 months who were admitted to the infectious disease outpatient clinic or hospitalized. Body temperature of patients was measured with a tympanic infrared thermometer that is routinely used and with NCIT at the same time. Temperature values, age, and disease of patients were recorded. Results: During the study, 220 measurements were obtained from 76 patients. Fifteen 6.8%) of 220 tympanic measurements were > 38.0 degrees C, and 7 of them were also > 38.0 degrees C with NCIT measurements. The difference between tympanic and NCIT measurements for each reading was calculated. Positive and negative values were obtained when tympanic readings were higher and lower than NCIT readings, respectively. Mean difference was -0.5 degrees C (+/- 0.3) for negative values and 0.6 degrees C (+/- 0.4)degrees C for positive ones. Conclusion: NCIT can be preferred for screening of fever, but before routine use in hospitals, more expanded studies with NCIT should be performed.
引用
收藏
页码:52 / 55
页数:4
相关论文
共 50 条
  • [21] Correction of Human Forehead Temperature Variations Measured by Non-Contact Infrared Thermometer
    Shajkofci, Adrian
    [J]. IEEE SENSORS JOURNAL, 2022, 22 (17) : 16750 - 16755
  • [22] Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer
    Poveda, Vanessa de Brito
    Nascimento, Ariane de Souza
    [J]. REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2016, 50 (06) : 945 - 950
  • [23] Feasibility and utility of infrared thermography as a thermometer: Comparison with oral and tympanic thermometry
    Haldeman, LA
    Allen, TL
    Chan, KJ
    Snow, GL
    [J]. ANNALS OF EMERGENCY MEDICINE, 2004, 44 (04) : S53 - S53
  • [24] A Comparision of Axillary with Infrared Tympanic and Non-Contact Infrared Thermometry
    Coban, Bayram
    Dolgun, Anil
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2016, 10 (03): : 82 - 85
  • [25] Clinical Accuracy of Non-Contact Forehead Infrared Thermometer Measurement in Children: An Observational Study
    Kim, Yeon-Mi
    Jang, Myung-Roul
    Moon, Ju-Ryoung
    Park, Goeun
    An, Ye-Jin
    Seo, Jeong-Meen
    [J]. CHILDREN-BASEL, 2022, 9 (09):
  • [26] Performance of non-contact infrared thermometer for detecting febrile children in hospital and ambulatory settings
    Chiappini, Elena
    Sollai, Sara
    Longhi, Riccardo
    Morandini, Liana
    Laghi, Anna
    Osio, Catia Emilia
    Persiani, Mario
    Lonati, Silvia
    Picchi, Raffaella
    Bonsignori, Francesca
    Mannelli, Francesco
    Galli, Luisa
    de Martino, Maurizio
    [J]. JOURNAL OF CLINICAL NURSING, 2011, 20 (9-10) : 1311 - 1318
  • [27] Non-contact Infrared Thermometer for Monitoring Population Temperature Infected with COVID-19
    Mabrouki, Jamal
    Azrour, Mourade
    Boubekraoui, Amina
    Dhiba, Driss
    El Hajjaji, Souad
    [J]. ADVANCED INTELLIGENT SYSTEMS FOR SUSTAINABLE DEVELOPMENT (AI2SD'2020), VOL 1, 2022, 1417 : 985 - 995
  • [28] Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients
    Can, Emrah
    Bulbul, Ali
    Uslu, Sinan
    Nuhoglu, Asiye
    [J]. TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (03): : 257 - 263
  • [29] THE GENIUS INFRARED TYMPANIC THERMOMETER - AN EVALUATION FOR CLINICAL USE
    EDGE, G
    MORGAN, M
    [J]. ANAESTHESIA, 1993, 48 (07) : 604 - 607
  • [30] Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer
    Gasim G.I.
    Musa I.R.
    Abdien M.T.
    Adam I.
    [J]. BMC Research Notes, 6 (1)