Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer

被引:0
|
作者
Poveda, Vanessa de Brito [1 ]
Nascimento, Ariane de Souza [2 ]
机构
[1] Univ Sao Paulo, Escola Enfermagem, Dept Enfermagem Med Cirurg, Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Escola Enfermagem, Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Hypothermia; Body Temperature; Thermometers; Perioperative Nursing; CORE TEMPERATURE; SURGICAL-PATIENTS; HYPOTHERMIA; ACCURACY; CHILDREN;
D O I
10.1590/S0080-623420160000700010
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To verify the correlation between temperature measurements performed using an infrared tympanic thermometer and an esophageal thermometer during the intraoperative period. Method: A longitudinal study of repeated measures was performed including subjects aged 18 years or older undergoing elective oncologic surgery of the digestive system, with anesthesia duration of at least 1 hour. Temperature measurements were performed simultaneously by a calibrated esophageal thermometer and by a calibrated infrared tympanic thermometer, with laboratory reading precision of +/- 0.2 degrees C. The operating room temperature remained between 19 and 21 degrees C. Results: The study included 51 patients, mostly men (51%), white (80.4%). All patients were kept warm by a forced-air heating system, for an average of 264.14 minutes (SD = 87.7). The two temperature measurements showed no different behavior over time (p = 0.2205), however, tympanic measurements were consistently 1.24 degrees C lower (p<0.0001). Conclusion: The tympanic thermometer presented reliable results but reflected lower temperatures than the esophageal thermometer.
引用
收藏
页码:945 / 950
页数:6
相关论文
共 50 条
  • [1] INFRARED TYMPANIC THERMOMETER - EVALUATION OF A NEW CLINICAL THERMOMETER
    SHINOZAKI, T
    DEANE, R
    PERKINS, FM
    [J]. CRITICAL CARE MEDICINE, 1988, 16 (02) : 148 - 150
  • [2] Accuracy of an infrared tympanic thermometer
    Amoateng-Adjepong, Y
    Del Mundo, J
    Manthous, CA
    [J]. CHEST, 1999, 115 (04) : 1002 - 1005
  • [3] Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer
    Bayhan, Cihangul
    Ozsurekci, Yasemin
    Tekcam, Necmiye
    Guloglu, Ayse
    Ehliz, Gulten
    Ceyhan, Mehmet
    Kara, Ates
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (02): : 52 - 55
  • [4] Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer
    Ilce, Arzu
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (04): : 200 - 200
  • [5] The usefulness of an earphone-type infrared tympanic thermometer for Intraoperative core temperature monitoring
    Kiya, Tomohiro
    Yamakage, Michiaki
    Hayase, Tomo
    Satoh, Jun-Ichi
    Namiki, Akiyoshi
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 (06): : 1688 - 1692
  • [6] Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer
    Gasim G.I.
    Musa I.R.
    Abdien M.T.
    Adam I.
    [J]. BMC Research Notes, 6 (1)
  • [7] Accuracy of parents in measuring body temperature with a tympanic thermometer
    Robinson J.L.
    Jou H.
    Spady D.W.
    [J]. BMC Family Practice, 6 (1)
  • [8] The effect of factors such as handedness, sex and age on body temperature measured by an infrared 'tympanic' thermometer
    School of Applied Science, University of Glamorgan, Mid Glamorgan, CF37 1DL, United Kingdom
    不详
    [J]. J. Med. Eng. Technol., 2006, 4 (235-241):
  • [9] Evaluation of the performance of an infrared tympanic thermometer
    Cascetta, Furio
    [J]. Measurement: Journal of the International Measurement Confederation, 1995, 16 (04): : 239 - 246
  • [10] Estimation of contact tympanic membrane temperature with a noncontact infrared thermometer
    Temdrup, TE
    Crofton, DJ
    Mortelliti, AJ
    Kelley, R
    Rajk, J
    [J]. ANNALS OF EMERGENCY MEDICINE, 1997, 30 (02) : 171 - 175