Accuracy of parents in measuring body temperature with a tympanic thermometer

被引:16
|
作者
Robinson J.L. [1 ]
Jou H. [1 ]
Spady D.W. [1 ]
机构
[1] Department of Pediatrics, Stollery Children's Hospital, 2C3 Walter MacKenzie Centre, Edmonton, Alta. T6G 2B7
关键词
Absolute Difference; Health Care Worker; Rectal Temperature; Skilled Operator; Severe Acute Respiratory Syndrome;
D O I
10.1186/1471-2296-6-3
中图分类号
学科分类号
摘要
Background: It is now common for parents to measure tympanic temperatures in children. The objective of this study was to assess the diagnostic accuracy of these measurements. Methods: Parents and then nurses measured the temperature of 60 children with a tympanic thermometer designed for home use (home thermometer). The reference standard was a temperature measured by a nurse with a model of tympanic thermometer commonly used in hospitals (hospital thermometer). A difference of ≥ 0.5°C was considered clinically significant. A fever was defined as a temperature ≥ 38.5°C. Results: The mean absolute difference between the readings done by the parent and the nurse with the home thermometer was 0.44 ± 0.61°C, and 33% of the readings differed by ≥ 0.5°C. The mean absolute difference between the readings done by the parent with the home thermometer and the nurse with the hospital thermometer was 0.51 ± 0.63°C, and 72% of the readings differed by ≥ 0.5°C. Using the home thermometer, parents detected fever with a sensitivity of 76% (95% CI 50-93%), a specificity of 95% (95% CI 84-99%), a positive predictive value of 87% (95% CI 60-98%), and a negative predictive value of 91% (95% CI 79-98%). In comparing the readings the nurse obtained from the two different tympanic thermometers, the mean absolute difference was 0.24 ± 0.22°C. Nurses detected fever with a sensitivity of 94% (95% CI 71-100%), a specificity of 88% (95% CI 75-96%), a positive predictive value of 76% (95% CI 53-92%), and a negative predictive value of 97% (95% CI 87-100%) using the home thermometer. The intraclass correlation coefficient for the three sets of readings was 0.80, and the consistency of readings was not affected by the body temperature. Conclusions: The readings done by parents with a tympanic thermometer designed for home use differed a clinically significant amount from the reference standard (readings done by nurses with a model of tympanic thermometer commonly used in hospitals) the majority of the time, and parents failed to detect fever about one-quarter of the time. Tympanic readings reported by parents should be interpreted with great caution. © 2005 Robinson et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
  • [1] TYMPANIC THERMOMETER ACCURACY
    NIERMAN, DM
    [J]. ANNALS OF EMERGENCY MEDICINE, 1992, 21 (10) : 1300 - 1300
  • [2] Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer
    Gasim G.I.
    Musa I.R.
    Abdien M.T.
    Adam I.
    [J]. BMC Research Notes, 6 (1)
  • [3] Accuracy of an infrared tympanic thermometer
    Amoateng-Adjepong, Y
    Del Mundo, J
    Manthous, CA
    [J]. CHEST, 1999, 115 (04) : 1002 - 1005
  • [4] Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer
    Poveda, Vanessa de Brito
    Nascimento, Ariane de Souza
    [J]. REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2016, 50 (06) : 945 - 950
  • [5] THERMOMETER FOR MEASURING BODY TEMPERATURE IN HYPOTHERMIA
    CLARK, LC
    TROLANDER, H
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1954, 155 (03): : 251 - 252
  • [6] Analysis of the effect of lying on the ear on body temperature measurement using a tympanic thermometer
    Arslan, Gulsah Gurol
    Eser, Ismet
    Khorshid, Leyla
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2011, 61 (11) : 1065 - 1068
  • [7] The accuracy and precision of tympanic temperature with a new optical fiber thermometer during cardiac surgery
    Matsukawa, T
    Kawamura, A
    Ozaki, M
    Kumazawa, T
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U146 - U146
  • [8] Tympanic thermometer performance validation by use of a body-temperature fixed point blackbody
    Machin, G
    Simpson, R
    [J]. THERMOSENSE XXV, 2003, 5073 : 51 - 57
  • [9] MEASURING THE BODY-TEMPERATURE OF VEAL CALVES BY AN ELECTRONIC THERMOMETER
    EIKELENBOOM, JL
    GOOSSENS, HA
    [J]. TIJDSCHRIFT VOOR DIERGENEESKUNDE, 1980, 105 (02) : 71 - 73
  • [10] Clinical Accuracy of Tympanic Thermometer and Noncontact Infrared Skin Thermometer in Pediatric Practice An Alternative for Axillary Digital Thermometer
    Apa, Hursit
    Gozmen, Salih
    Bayram, Nuri
    Catikoglu, Asli
    Devrim, Fatma
    Karaarslan, Utku
    Gunay, Ilker
    Unal, Nurettin
    Devrim, Ilker
    [J]. PEDIATRIC EMERGENCY CARE, 2013, 29 (09) : 992 - 997