Intraoperative body temperature control: esophageal thermometer versus infrared tympanic thermometer

被引:0
|
作者
Poveda, Vanessa de Brito [1 ]
Nascimento, Ariane de Souza [2 ]
机构
[1] Univ Sao Paulo, Escola Enfermagem, Dept Enfermagem Med Cirurg, Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Escola Enfermagem, Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Hypothermia; Body Temperature; Thermometers; Perioperative Nursing; CORE TEMPERATURE; SURGICAL-PATIENTS; HYPOTHERMIA; ACCURACY; CHILDREN;
D O I
10.1590/S0080-623420160000700010
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objective: To verify the correlation between temperature measurements performed using an infrared tympanic thermometer and an esophageal thermometer during the intraoperative period. Method: A longitudinal study of repeated measures was performed including subjects aged 18 years or older undergoing elective oncologic surgery of the digestive system, with anesthesia duration of at least 1 hour. Temperature measurements were performed simultaneously by a calibrated esophageal thermometer and by a calibrated infrared tympanic thermometer, with laboratory reading precision of +/- 0.2 degrees C. The operating room temperature remained between 19 and 21 degrees C. Results: The study included 51 patients, mostly men (51%), white (80.4%). All patients were kept warm by a forced-air heating system, for an average of 264.14 minutes (SD = 87.7). The two temperature measurements showed no different behavior over time (p = 0.2205), however, tympanic measurements were consistently 1.24 degrees C lower (p<0.0001). Conclusion: The tympanic thermometer presented reliable results but reflected lower temperatures than the esophageal thermometer.
引用
收藏
页码:945 / 950
页数:6
相关论文
共 50 条
  • [41] TEMPERATURE BIOFEEDBACK - SOME ADVANTAGES OF THE INFRARED THERMOMETER
    OLESEN, E
    PEPER, E
    BIOFEEDBACK AND SELF-REGULATION, 1985, 10 (01): : 110 - 110
  • [42] Intravenous fluid temperature management by infrared thermometer
    Lapostolle, F
    Catineau, J
    Le Toumelin, P
    Proust, C
    Garrigue, B
    Galinski, M
    Adnet, F
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (02): : 174 - 176
  • [43] Estimating the time of death with infrared tympanic thermometer: a new prospective study in France
    Angélique Franchi
    Isabelle Clerc-Urmès
    Laurent Martrille
    International Journal of Legal Medicine, 2020, 134 : 591 - 595
  • [44] Tympanic Temperature Comparison with Oral Mercury Thermometer Readings in an OPD Setting
    Rabbani, Mohammad Zafar
    Amir, Mohammed
    Malik, Munir
    Mufti, Mazhar
    Bin Pervez, Mohammad
    Iftekhar, Sahar
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2010, 20 (01): : 33 - 36
  • [45] Estimating the time of death with infrared tympanic thermometer: a new prospective study in France
    Franchi, Angelique
    Clerc-Urmes, Isabelle
    Martrille, Laurent
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2020, 134 (02) : 591 - 595
  • [46] The use of a resistance thermometer for recording the body temperature
    Gordon, B
    von Stanley, E
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1927, 13 : 78 - 80
  • [47] Routine use of an infrared thermometer in measuring the body surface temperature pattern of horse limbs
    Allmers, E
    Hollenberg, C
    Heldt, S
    Meyer, W
    TIERAERZTLICHE PRAXIS AUSGABE GROSSTIERE NUTZTIERE, 2005, 33 (03): : 181 - 187
  • [48] Correlation between superficial body temperatures measured with an infrared thermometer and rectal temperature in alpacas
    Vilela, Jorge L.
    Goycochea, Gianella
    Serna, Allison
    Veramendi, Frank
    Ascue, Jorge
    Callan, Milagros
    Jauregui, Andrea
    Miranda, Almendra
    Montalvo, Pamela
    Sandoval, Aranza
    Solis, Sebastian
    JOURNAL OF ANIMAL SCIENCE, 2020, 98 : 214 - 214
  • [49] Determining the emissivity and temperature of building materials by infrared thermometer
    Chen, Hsuan-Yu
    Chen, Chiachung
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 126 : 130 - 137
  • [50] Reliability of an infrared auditory thermometer in the measurement of oral temperature
    Moya Villaescusa, M. Jose
    Perez, A. Sanchez
    Bermejo Fenoll, Ambrosio
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (06): : E385 - E389