Clinical Accuracy of Non-Contact Forehead Infrared Thermometer Measurement in Children: An Observational Study

被引:3
|
作者
Kim, Yeon-Mi [1 ]
Jang, Myung-Roul [1 ]
Moon, Ju-Ryoung [2 ]
Park, Goeun [3 ]
An, Ye-Jin [1 ]
Seo, Jeong-Meen [4 ]
机构
[1] Samsung Med Ctr, Heart Vasc Stroke Inst, Dept Nursing, Seoul 06351, South Korea
[2] Samsung Med Ctr, Cardiac Ctr, Heart Vasc Stroke Inst, Dept Nursing, Seoul 06351, South Korea
[3] Samsung Med Ctr, Biomed Stat Ctr, Res Inst Future Med, Seoul 06351, South Korea
[4] Sungkyunkwan Univ, Samsung Med Ctr, Dept Gen Surg, Div Pediat Surg,Coll Med, Seoul 06351, South Korea
来源
CHILDREN-BASEL | 2022年 / 9卷 / 09期
关键词
body temperature; thermometers; infrared rays; fever; child; PRIMARY-CARE; TEMPERATURE-MEASUREMENTS; BODY-TEMPERATURE; AXILLARY; FEVER; RELIABILITY; SKIN; PERFORMANCE; UNCERTAINTY; EAR;
D O I
10.3390/children9091389
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
We evaluated the clinical reliability and utility of temperature measurements using no-contact forehead infrared thermometers (NCFITs) by comparing their temperature measurements with those obtained using infrared tympanic thermometers (IRTTs) in children. In this observational, prospective, and cross-sectional study, we enrolled 255 children (aged 1 month to 18 years) from the pediatric surgery ward at a tertiary medical center in Korea. The mean age of the children was 9.05 +/- 5.39 years, and 54.9% were boys. The incidence rate of fever, defined as an IRTT reading of >= 38.0 degrees C, was 15.7%. The ICC coefficient for the assessment of agreement between temperatures recorded by the NCFIT and IRTT was 0.87, and the K-coefficient was 0.83. The bias and 95% limits of agreement were 0.15 degrees C (-0.43 to 0.73). For an accurate diagnosis of fever (>= 38 degrees C), the false-negative rate was much lower, but the false-positive rate was higher, especially in 6-year-old children. Therefore, NCFITs can be used to screen children for fever. However, a secondary check is required using another thermometer when the child's temperature is >38 degrees C. NCFITs are proposed for screening but not for measuring the temperature. For the latter, an accurate and reliable thermometer shall be used.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Clinical accuracy of non-contact forehead infrared thermometer and infrared tympanic thermometer in postoperative adult patients: A comparative study.
    Kameda, Norihiro
    [J]. JOURNAL OF PERIOPERATIVE PRACTICE, 2022, 32 (06) : 142 - 148
  • [2] Clinical accuracy of a non-contact infrared skin thermometer in paediatric practice
    Teran, C. G.
    Torrez-Llanos, J.
    Teran-Miranda, T. E.
    Balderrama, C.
    Shah, N. S.
    Villarroel, P.
    [J]. CHILD CARE HEALTH AND DEVELOPMENT, 2012, 38 (04) : 471 - 476
  • [3] Clinical accuracy of non-contact infrared thermometer from umbilical region in children: A new side
    Apa, Hursit
    Gozmen, Salih
    Keskin-Gozmen, Sukran
    Aslan, Fatma
    Bayram, Nuri
    Devrim, Ilker
    [J]. TURKISH JOURNAL OF PEDIATRICS, 2016, 58 (02) : 180 - 186
  • [4] Correction of Human Forehead Temperature Variations Measured by Non-Contact Infrared Thermometer
    Shajkofci, Adrian
    [J]. IEEE SENSORS JOURNAL, 2022, 22 (17) : 16750 - 16755
  • [5] Comparison of non-contact infrared forehead thermometer to standard temperature measurement in neonatal intensive care unit patients
    Can, Emrah
    Bulbul, Ali
    Uslu, Sinan
    Nuhoglu, Asiye
    [J]. TURK PEDIATRI ARSIVI-TURKISH ARCHIVES OF PEDIATRICS, 2010, 45 (03): : 257 - 263
  • [6] Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer
    Bayhan, Cihangul
    Ozsurekci, Yasemin
    Tekcam, Necmiye
    Guloglu, Ayse
    Ehliz, Gulten
    Ceyhan, Mehmet
    Kara, Ates
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (02): : 52 - 55
  • [7] Comparison of Infrared Tympanic Thermometer with Non-Contact Infrared Thermometer
    Ilce, Arzu
    [J]. JOURNAL OF PEDIATRIC INFECTION, 2014, 8 (04): : 200 - 200
  • [8] Assessment of Non-Contact Infrared Thermometer Measurement Sites in Birds
    Anderson, Jessica
    Kaplan-Stein, Sara
    Adolph, Stephen
    Peralta, Jose M.
    [J]. JOURNAL OF APPLIED ANIMAL WELFARE SCIENCE, 2020, 23 (02) : 131 - 139
  • [9] DESIGN OF A NON-CONTACT INFRARED THERMOMETER
    Long, Guangli
    [J]. INTERNATIONAL JOURNAL ON SMART SENSING AND INTELLIGENT SYSTEMS, 2016, 9 (02): : 1110 - 1129
  • [10] Performance characterization of non-contact infrared thermometers (NCITs) for forehead temperature measurement
    Sullivan, Stacey J. L.
    Seay, Nathanael
    Zhu, Liang
    Rinaldi, Jean E.
    Hariharan, Prasanna
    Vesnovsky, Oleg
    Topoleski, L. D. Timmie
    [J]. MEDICAL ENGINEERING & PHYSICS, 2021, 93 : 93 - 99