Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

被引:0
|
作者
Lee, Jung-Woo [1 ]
Choe, Bo-Young [1 ]
Yoon, Sung-Ik [1 ]
Choi, Chi-Bong [1 ]
Huh, Soon-Nyoung [2 ]
机构
[1] Catholic Univ Korea, Kangnam St Marys Hosp, Coll Med, Dept Biomed Engn, 505 Banpo Dong, Seoul 137040, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul 110744, South Korea
来源
关键词
Birdcage Resonator; 3; T; Signal-to-Noise Ratio (SNR);
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-images of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators was evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR images of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the images of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40 similar to 80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.
引用
收藏
页码:48 / 60
页数:13
相关论文
共 50 条
  • [41] Dual Resonant RF Coil for 1.5T and 3T MRI Systems Employing FPCB Etched Sub-legs
    Ahmad, Sheikh Faisal
    Son, Hyeok Woo
    Choi, Ick Chang
    Kim, Young Cheol
    Chang, Yongmin
    Kim, Hyun Deok
    ASIA-PACIFIC MICROWAVE CONFERENCE 2011, 2011, : 1442 - 1445
  • [42] RF Heating Due to a 3 T Birdcage, Whole-body Transmit Coil in Anesthetized Sheep
    Turdumamatov, Samat
    Oto, Cagdas
    Algin, Oktay
    Erguder, Hamza
    Malas, Tahir
    EMAGRES, 2020, 9 (02): : 183 - 188
  • [43] Design and Development of a General-Purpose Transmit/Receive (T/R) Switch for 3T MRI, Compatible for a Linear, Quadrature and Double-Tuned RF Coil
    Thapa, Bijaya
    Kaggie, Joshua
    Sapkota, Nabraj
    Frank, Deborah
    Jeong, Eun-Kee
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2016, 46 (02) : 57 - 65
  • [44] SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024, 2024, : 131 - 133
  • [45] A 64-channel 3T array coil for accelerated brain MRI
    Keil, Boris
    Blau, James N.
    Biber, Stephan
    Hoecht, Philipp
    Tountcheva, Veneta
    Setsompop, Kawin
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 248 - 258
  • [46] Eight-channel transmit/receive body MRI coil at 3T
    Vernickel, P.
    Roeschmann, P.
    Findeklee, C.
    Luedeke, K.-M.
    Leussler, Ch.
    Overwag, J.
    Katscher, U.
    Graesslin, I.
    Schuenemann, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 381 - 389
  • [47] An eight-channel sodium/proton coil for brain MRI at 3T
    Lakshmanan, Karthik
    Brown, Ryan
    Madelin, Guillaume
    Qian, Yongxian
    Boada, Fernando
    Wiggins, Graham C.
    NMR IN BIOMEDICINE, 2018, 31 (02)
  • [48] Extended curvature birdcage coil design for localized magnetic field in 9.4 T MRI for multiple mouse imaging
    Hernandez, Daniel
    Nam, Taewoo
    Lee, Eunwoo
    Lee, Jae Jun
    Kim, Kyoung-Nam
    AIP ADVANCES, 2024, 14 (06)
  • [49] Procedural Development of RF Tx/Rx Circularly Polarized Birdcage Coil at 1.5T MR system
    Patwardhan, Rutuja
    Sonawane, Shrikant
    Harsh, Rajesh
    Gaikwad, Sandeep
    2018 INTERNATIONAL CONFERENCE ON ADVANCES IN COMMUNICATION AND COMPUTING TECHNOLOGY (ICACCT), 2018, : 616 - 618
  • [50] Comparison of a 32-Channel Coil and a Six-Channel Coil for MRI of the Prostate at 3T
    Sammet, S.
    Wei, W.
    Reiss, B.
    Liang, J.
    Jia, G.
    Aguila, F.
    Choi, S.
    Knopp, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)