Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

被引:0
|
作者
Lee, Jung-Woo [1 ]
Choe, Bo-Young [1 ]
Yoon, Sung-Ik [1 ]
Choi, Chi-Bong [1 ]
Huh, Soon-Nyoung [2 ]
机构
[1] Catholic Univ Korea, Kangnam St Marys Hosp, Coll Med, Dept Biomed Engn, 505 Banpo Dong, Seoul 137040, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul 110744, South Korea
来源
关键词
Birdcage Resonator; 3; T; Signal-to-Noise Ratio (SNR);
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-images of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators was evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR images of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the images of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40 similar to 80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.
引用
收藏
页码:48 / 60
页数:13
相关论文
共 50 条
  • [21] Simulations of a birdcage coil B1+ field on a human body model for designing a 3T multichannel TMS/MRI head coil array
    de Lara, Lucia I. Navarro
    Rad, Laleh Golestani
    Makarov, Sergey N.
    Stockmann, Jason
    Wald, Lawrence L.
    Nummenmaa, Aapo
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4752 - 4755
  • [22] Impact of RF Shimming on RF-Induced Heating Near Implantable Medical Electrodes in a 3T MRI Coil
    Zeng, Qi
    Wang, Qingyan
    Kainz, Wolfgang
    Chen, Ji
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2020, 62 (01) : 52 - 64
  • [23] Conformal Occipital 18-Channel Receive-Only RF Coil for 3T MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 43 - 45
  • [24] Double Band-Pass Birdcage RF Coil for Dual Elements NMR Imaging at 4.7T MRI system
    Ahn, Chang Min
    Sheikh, Faisal Ahmad
    Kim, Yeong Cheol
    Kim, Hyun Deok
    2018 IEEE INTERNATIONAL RF AND MICROWAVE CONFERENCE (RFM 2018), 2018, : 189 - 192
  • [25] Evaluation of RF interactions between a 3T birdcage transmit coil and transcranial magnetic stimulation coils using a realistically shaped head phantom
    Navarro de Lara, Lucia I.
    Golestanirad, Laleh
    Makarov, Sergey N.
    Stockmann, Jason P.
    Wald, Lawrence L.
    Nummenmaa, Aapo
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 1061 - 1075
  • [26] Saw-Tooth Shaped Legs Birdcage RF Coil for Small Animal NMR Imaging at 1.5T MRI System
    Kim, Jung-Min
    Ahmad, Sheikh Faisal
    Choi, Ick Chang
    Kim, Young Cheol
    Kim, Hyun Deok
    2013 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC 2013), 2013, : 542 - 544
  • [27] Detector Shielding Design of a PET Inserts in a 3T MRI System
    Lee, Brian J.
    Watkins, Ronald D.
    Chang, Chen-Ming
    Kwon, Inyong
    Levin, Craig S.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [28] The first clinical test of Add-on PET: A PET-integrated RF coil for 3T MRI
    Takahashi, Miwako
    Nishikido, Fumihiko
    Akamatsu, Go
    Tashima, Hideaki
    Suga, Mikio
    Iwao, Yuma
    Yamaya, Taiga
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [29] In Vivo Radiofrequency Heating in Swine in a 3T (123.2-MHz) Birdcage Whole Body Coil
    Shrivastava, Devashish
    Utecht, Lynn
    Tian, Jinfeng
    Hughes, John
    Vaughan, J. Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1141 - 1150
  • [30] Design and Analysis of Microstrip-Based RF Birdcage Coil for 1.5 T Magnetic Resonance Imaging
    Krishnan Thiyagarajan
    Thangavelu Kesavamurthy
    Gattu Bharathkumar
    Applied Magnetic Resonance, 2014, 45 : 255 - 268