SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI

被引:0
|
作者
Mathieu, William [1 ]
Popovic, Milica [1 ]
Farivar, Reza [2 ]
机构
[1] McGill Univ, Dept Elect & Comp Engn, Montreal, PQ, Canada
[2] McGill Univ, Dept Ophthalmol, Montreal, PQ, Canada
关键词
MRI; RF Coils; Phased Arrays; Flexible RF Coils;
D O I
10.1109/IMBIOC60287.2024.10590301
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In head MRI applications, flexible RF receive-only head coils can offer improved SNR and patient comfort. In our work, we achieve partial, but sufficient, flexibility by decomposing an average head surface into movable, semi-flexible plates that comfortably adapt to the surface of the head. As a result, we can include a larger number of smaller elements, pushing the boundary of achievable SNR while still being able to resolve brain areas. In order to test the viability of the design, we investigate the SNR variability of two 12-channel frontal plate arrays when they are adapted to fit differently sized heads. The elements were constructed on a 3D-printed thermoplastic polyurethane (TPU) flexible substrate, with conductive loops on the inside surface to minimize their distance to the head. Experiments were conducted in an MRI scanner in which a spherical phantom was imaged by the frontal plate arrays together at four positions. We demonstrate that SNR decreases, as expected, as the gap between the plates increases, but in an acceptable range. The overall range of inter-plate distance results in SNR variability of approximately 15%. These results support the overall feasibility of the larger head coil composed of eight movable plates: the mechanical gaps that would appear for larger heads would not compromise the SNR and, therefore, signal integrity and would still outperform a similar fixed-size head coil.
引用
收藏
页码:131 / 133
页数:3
相关论文
共 50 条
  • [1] Improvement of SNR and acquisition acceleration using a 32-channel head coil compared to a 12-channel head coil at 3T
    Reiss-Zimmermann, Martin
    Gutberlet, Marcel
    Koestler, Herbert
    Fritzsch, Dominik
    Hoffmann, Karl-Titus
    ACTA RADIOLOGICA, 2013, 54 (06) : 702 - 708
  • [2] Image quality comparisons of coil setups in 3T MRI for brain and head and neck radiotherapy simulations
    Kaza, Evangelia
    Guenette, Jeffrey P.
    Guthier, Christian, V
    Hatch, Steven
    Marques, Alexander
    Singer, Lisa
    Schoenfeld, Jonathan D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [3] A Passive and Conformal Magnetic Metasurface for 3T MRI Birdcage Coil
    Rotundo, Sabrina
    Brizi, Danilo
    Carluccio, Giuseppe
    Lakshmanan, Karthik
    Collins, Christopher M.
    Lattanzi, Riccardo
    Monorchio, Agostino
    2023 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS, ICEAA, 2023, : 222 - 224
  • [4] Design and Characterization of a Metasurface Enhancement Plate for 3T MRI
    Stoja, Endri
    Konstandin, Simon
    Wilke, Robin Niklas
    Philipp, Dennis
    Umathum, Reiner
    Jenne, Juergen
    Betancourt, Diego
    Bertuch, Thomas
    Guenther, Matthias
    2020 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2020,
  • [5] Impacts of RF Shimming on Local SAR Caused by MRI 3T Birdcage Coil near Femoral Plate Implants
    Zeng, Qi
    Guo, Ran
    Zheng, Jianfeng
    Chen, Ji
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1005 - 1006
  • [6] A 64-channel 3T array coil for accelerated brain MRI
    Keil, Boris
    Blau, James N.
    Biber, Stephan
    Hoecht, Philipp
    Tountcheva, Veneta
    Setsompop, Kawin
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 248 - 258
  • [7] Eight-channel transmit/receive body MRI coil at 3T
    Vernickel, P.
    Roeschmann, P.
    Findeklee, C.
    Luedeke, K.-M.
    Leussler, Ch.
    Overwag, J.
    Katscher, U.
    Graesslin, I.
    Schuenemann, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 381 - 389
  • [8] An eight-channel sodium/proton coil for brain MRI at 3T
    Lakshmanan, Karthik
    Brown, Ryan
    Madelin, Guillaume
    Qian, Yongxian
    Boada, Fernando
    Wiggins, Graham C.
    NMR IN BIOMEDICINE, 2018, 31 (02)
  • [9] A deep brain stimulation-conditioned RF coil for 3T MRI
    Kutscha, Nicolas
    Mahmutovic, Mirsad
    Bhusal, Bhumi
    Vu, Jasmine
    Chemlali, Chaimaa
    Hansen, Sam-Luca J. D.
    May, Markus W.
    Knake, Susanne
    Golestanirad, Laleh
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1411 - 1426
  • [10] Comparison of a 32-Channel Coil and a Six-Channel Coil for MRI of the Prostate at 3T
    Sammet, S.
    Wei, W.
    Reiss, B.
    Liang, J.
    Jia, G.
    Aguila, F.
    Choi, S.
    Knopp, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)