In head MRI applications, flexible RF receive-only head coils can offer improved SNR and patient comfort. In our work, we achieve partial, but sufficient, flexibility by decomposing an average head surface into movable, semi-flexible plates that comfortably adapt to the surface of the head. As a result, we can include a larger number of smaller elements, pushing the boundary of achievable SNR while still being able to resolve brain areas. In order to test the viability of the design, we investigate the SNR variability of two 12-channel frontal plate arrays when they are adapted to fit differently sized heads. The elements were constructed on a 3D-printed thermoplastic polyurethane (TPU) flexible substrate, with conductive loops on the inside surface to minimize their distance to the head. Experiments were conducted in an MRI scanner in which a spherical phantom was imaged by the frontal plate arrays together at four positions. We demonstrate that SNR decreases, as expected, as the gap between the plates increases, but in an acceptable range. The overall range of inter-plate distance results in SNR variability of approximately 15%. These results support the overall feasibility of the larger head coil composed of eight movable plates: the mechanical gaps that would appear for larger heads would not compromise the SNR and, therefore, signal integrity and would still outperform a similar fixed-size head coil.
引用
收藏
页码:131 / 133
页数:3
相关论文
共 50 条
  • [21] An eight-channel T/R head coil for parallel transmit MRI at 3T using ultra-low output impedance amplifiers
    Moody, Katherine Lynn
    Hollingsworth, Neal A.
    Zhao, Feng
    Nielsen, Jon-Fredrik
    Noll, Douglas C.
    Wright, Steven M.
    McDougall, Mary Preston
    JOURNAL OF MAGNETIC RESONANCE, 2014, 246 : 62 - 68
  • [22] PROSTATE CANCER: COMPARING THE IMAGE QUALITY OF ENDORECTAL MRI AT 1.5T WITH 3T MRI WITHOUT THE ENDORECTAL COIL
    Jia, Guang
    Shah, Zarine
    Wei, Lai
    Knopp, Michael
    JOURNAL OF UROLOGY, 2013, 189 (04): : E895 - E896
  • [23] High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil
    Bittersohl, Bernd
    Huang, Thomas
    Schneider, Erika
    Biazar, Philip
    Winalski, Carl
    Lang, Philipp
    Yoshioka, Hiroshi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 701 - 707
  • [24] Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System
    Lee, Jung-Woo
    Choe, Bo-Young
    Yoon, Sung-Ik
    Choi, Chi-Bong
    Huh, Soon-Nyoung
    JOURNAL OF THE KOREAN MAGNETIC RESONANCE SOCIETY, 2005, 9 (01): : 48 - 60
  • [25] Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI
    Ryu, Yeun Chul
    JOURNAL OF MAGNETICS, 2017, 22 (02) : 238 - 243
  • [26] MRI compatibility study of an integrated PET/RF-coil prototype system at 3T
    Akram, Md Shahadat Hossain
    Obata, Takayuki
    Suga, Mikio
    Nishikido, Fumihiko
    Yoshida, Eiji
    Saito, Kazuyuki
    Yamaya, Taiga
    JOURNAL OF MAGNETIC RESONANCE, 2017, 283 : 62 - 70
  • [27] Design of Hexagonal RF Surface coil for 3T MRI Scanner by Characteristic Mode Analysis
    Ullah, Rafi
    Venkatesan, Soundarya
    2022 IEEE MICROWAVES, ANTENNAS, AND PROPAGATION CONFERENCE, MAPCON, 2022, : 1100 - 1103
  • [28] 10-channel phased-array coil for carotid wall MRI at 3T
    de Buck, Matthijs H. S.
    Jezzard, Peter
    Frost, Robert
    Randell, Chris
    Hurst, Katherine
    Choudhury, Robin P.
    Robson, Matthew D.
    Biasiolli, Luca
    PLOS ONE, 2023, 18 (08):
  • [29] Influence of External Cables on EM Exposure Investigated with a Human Model in a 3T MRI Coil
    Kozlov, M.
    Weiskopf, N.
    Moeller, H. E.
    2019 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2019, : 59 - 60
  • [30] Influence of 3T MRI coil modeling on EM exposure estimation using a human model
    Kozlov, M.
    Weiskopf, N.
    Moeller, H. E.
    2019 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND USNC-URSI RADIO SCIENCE MEETING, 2019, : 535 - 536