High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil

被引:20
|
作者
Bittersohl, Bernd
Huang, Thomas
Schneider, Erika
Biazar, Philip
Winalski, Carl
Lang, Philipp
Yoshioka, Hiroshi
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[4] Harvard Univ, Sch Med, Dept Orthoped Surg, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
high-resolution; magnetic resonance imaging (MRI); triangular fibrocartilage complex; surface coil; 3; tesla;
D O I
10.1002/jmri.21077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). Materials and Methods: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees, 1 mm slice-thickness, 60 mm, field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees, 0.8 mm slice-thickness, 80 mm FOV, 256 X 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. Results: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. Conclusion: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 50 条
  • [1] High-resolution MR imaging of triangular fibrocartilage complex (TFCC): comparison of microscopy coils and a conventional small surface coil
    Yoshioka, H
    Ueno, T
    Tanaka, T
    Shindo, M
    Itai, Y
    SKELETAL RADIOLOGY, 2003, 32 (10) : 575 - 581
  • [2] High-resolution MR imaging of triangular fibrocartilage complex (TFCC): comparison of microscopy coils and a conventional small surface coil
    Hiroshi Yoshioka
    Teruko Ueno
    Toshikazu Tanaka
    Masashi Shindo
    Yuji Itai
    Skeletal Radiology, 2003, 32 : 575 - 581
  • [3] Comparison between high-resolution MRI with a microscopy coil and arthroscopy in triangular fibrocartilage complex injury
    Tanaka, Toshikazu
    Yoshioka, Hiroshi
    Ueno, Teruko
    Shindo, Masashi
    Ochiai, Naoyuki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (08): : 1308 - 1314
  • [4] High-Resolution 3T MR Imaging of the Triangular Fibrocartilage Complex
    von Borstel, Donald
    Wang, Michael
    Small, Kirstin
    Nozaki, Taiki
    Yoshioka, Hiroshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (01) : 3 - 15
  • [5] Traumatic injury of the triangular fibrocartilage complex (TFCC)-a refinement to the Palmer classification by using high-resolution 3-T MRI
    Zhan, Huili
    Bai, Rongjie
    Qian, Zhanhua
    Yang, Yong
    Zhang, Heng
    Yin, Yuming
    SKELETAL RADIOLOGY, 2020, 49 (10) : 1567 - 1579
  • [6] Traumatic injury of the triangular fibrocartilage complex (TFCC)—a refinement to the Palmer classification by using high-resolution 3-T MRI
    Huili Zhan
    Rongjie Bai
    Zhanhua Qian
    Yong Yang
    Heng Zhang
    Yuming Yin
    Skeletal Radiology, 2020, 49 : 1567 - 1579
  • [7] High-resolution 3 T MRI of traumatic and degenerative triangular fibrocartilage complex (TFCC) abnormalities using Palmer and Outerbridge classifications
    Nozaki, T.
    Rafijah, G.
    Yang, L.
    Ueno, T.
    Horiuchi, S.
    Hitt, D.
    Yoshioka, H.
    CLINICAL RADIOLOGY, 2017, 72 (10) : 904.e1 - 904.e10
  • [8] A special surface coil for high-resolution ocular MRI
    Hosten, N
    Lemke, AJ
    RADIOTHERAPY OF OCULAR DISEASE, 1997, 30 : 20 - 25
  • [9] High-resolution 3-T MRI of the triangular fibrocartilage complex in the wrist: injury pattern and MR features
    Zhan, Huili
    Zhang, Huibo
    Bai, Rongjie
    Qian, Zhanhua
    Liu, Yue
    Zhang, Heng
    Yin, Yuming
    SKELETAL RADIOLOGY, 2017, 46 (12) : 1695 - 1706
  • [10] High-resolution 3-T MRI of the triangular fibrocartilage complex in the wrist: injury pattern and MR features
    Huili Zhan
    Huibo Zhang
    Rongjie Bai
    Zhanhua Qian
    Yue Liu
    Heng Zhang
    Yuming Yin
    Skeletal Radiology, 2017, 46 : 1695 - 1706