High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil

被引:20
|
作者
Bittersohl, Bernd
Huang, Thomas
Schneider, Erika
Biazar, Philip
Winalski, Carl
Lang, Philipp
Yoshioka, Hiroshi
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[4] Harvard Univ, Sch Med, Dept Orthoped Surg, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
high-resolution; magnetic resonance imaging (MRI); triangular fibrocartilage complex; surface coil; 3; tesla;
D O I
10.1002/jmri.21077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). Materials and Methods: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees, 1 mm slice-thickness, 60 mm, field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees, 0.8 mm slice-thickness, 80 mm FOV, 256 X 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. Results: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. Conclusion: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 50 条
  • [41] Eight-channel transmit/receive body MRI coil at 3T
    Vernickel, P.
    Roeschmann, P.
    Findeklee, C.
    Luedeke, K.-M.
    Leussler, Ch.
    Overwag, J.
    Katscher, U.
    Graesslin, I.
    Schuenemann, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 381 - 389
  • [42] A 64-channel 3T array coil for accelerated brain MRI
    Keil, Boris
    Blau, James N.
    Biber, Stephan
    Hoecht, Philipp
    Tountcheva, Veneta
    Setsompop, Kawin
    Triantafyllou, Christina
    Wald, Lawrence L.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (01) : 248 - 258
  • [43] An eight-channel sodium/proton coil for brain MRI at 3T
    Lakshmanan, Karthik
    Brown, Ryan
    Madelin, Guillaume
    Qian, Yongxian
    Boada, Fernando
    Wiggins, Graham C.
    NMR IN BIOMEDICINE, 2018, 31 (02)
  • [44] A deep brain stimulation-conditioned RF coil for 3T MRI
    Kutscha, Nicolas
    Mahmutovic, Mirsad
    Bhusal, Bhumi
    Vu, Jasmine
    Chemlali, Chaimaa
    Hansen, Sam-Luca J. D.
    May, Markus W.
    Knake, Susanne
    Golestanirad, Laleh
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1411 - 1426
  • [45] The utility of high-resolution magnetic resonance imaging in the evaluation of the triangular fibrocartilage complex of the wrist
    Potter, HG
    AsnisErnberg, L
    Weiland, AJ
    Hotchkiss, RN
    Peterson, MGE
    McCormack, RR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (11): : 1675 - 1684
  • [46] Prostate MR imaging at 3T with a longitudinal array endorectal surface coil and phased array body coil
    Kim, David Y.
    Schnall, Mitchell D.
    Rosen, Mark A.
    Connick, Thomas
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1327 - 1330
  • [47] High-resolution intracranial vessel wall MRI in an elderly asymptomatic population: comparison of 3T and 7T
    Anita A. Harteveld
    Anja G. van der Kolk
    H. Bart van der Worp
    Nikki Dieleman
    Jeroen C. W. Siero
    Hugo J. Kuijf
    Catharina J. M. Frijns
    Peter R. Luijten
    Jaco J. M. Zwanenburg
    Jeroen Hendrikse
    European Radiology, 2017, 27 : 1585 - 1595
  • [48] High-resolution intracranial vessel wall MRI in an elderly asymptomatic population: comparison of 3T and 7T
    Harteveld, Anita A.
    van der Kolk, Anja G.
    van der Worp, H. Bart
    Dieleman, Nikki
    Siero, Jeroen C. W.
    Kuijf, Hugo J.
    Frijns, Catharina J. M.
    Luijten, Peter R.
    Zwanenburg, Jaco J. M.
    Hendrikse, Jeroen
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1585 - 1595
  • [49] High-resolution sonography of the triangular initial fibrocartilage: Initial experience and correlation with MRI and arthroscopic findings
    Keogh, CF
    Wong, AD
    Wells, NJ
    Barbarie, JE
    Cooperberg, PL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (02) : 333 - 336
  • [50] Intraocular metastases: differential diagnosis from uveal melanomas with high-resolution MRI using a surface coil
    Arne-Jörn Lemke
    Norbert Hosten
    Thomas Wiegel
    Robert D. Prinz
    Miriam Richter
    Nikolaos E. Bechrakis
    Paul I. Foerster
    Roland Felix
    European Radiology, 2001, 11 : 2593 - 2601