High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil

被引:20
|
作者
Bittersohl, Bernd
Huang, Thomas
Schneider, Erika
Biazar, Philip
Winalski, Carl
Lang, Philipp
Yoshioka, Hiroshi
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[4] Harvard Univ, Sch Med, Dept Orthoped Surg, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
high-resolution; magnetic resonance imaging (MRI); triangular fibrocartilage complex; surface coil; 3; tesla;
D O I
10.1002/jmri.21077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). Materials and Methods: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees, 1 mm slice-thickness, 60 mm, field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees, 0.8 mm slice-thickness, 80 mm FOV, 256 X 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. Results: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. Conclusion: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 50 条
  • [31] Study of ulnar variance with high-resolution MRI: Correlation with triangular fibrocartilage complex and cartilage of ulnar side of wrist
    Yoshioka, Hiroshi
    Tanaka, Toshikazu
    Ueno, Teruko
    Carrino, John A.
    Winalski, Carl S.
    Aliabadi, Piran
    Lang, Philipp
    Weissman, Barbara N.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 714 - 719
  • [32] Identification of long thoracic nerve on high-resolution 3T MRI
    Lee, Susan C.
    Geannette, Christian S.
    Sneag, Darryl B.
    CLINICAL IMAGING, 2020, 64 : 97 - 102
  • [33] Comparison of visibility of ulnar sided triangular fibrocartilage complex (TFCC) ligaments between isotropic three-dimensional and two-dimensional high-resolution FSE MR images
    Banjar, Mai
    Nor, Faimee Erwan Muhamat
    Singh, Pavel
    Horiuchi, Saya
    Quek, Swee Tian
    Yoshioka, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [34] DETECTION OF REGIONAL ALTERATIONS IN GADOLINIUM ENHANCEMENT OF CHOROIDAL MELANOMAS WITH HIGH-RESOLUTION SURFACE COIL MRI
    HUGHES, MS
    LASHKARI, K
    SANG, DN
    LEE, K
    CHENG, HM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 2120 - 2120
  • [35] Does a cleansing enema improve image quality of 3T surface coil multiparametric prostate MRI?
    Lim, Christopher
    Quon, Jeff
    McInnes, Matt
    Shabana, Wael M.
    El-Khodary, Mohamed
    Schieda, Nicola
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (03) : 689 - 697
  • [36] Design of a Halbach Magnet Gradient Coil for High-Resolution Portable MRI
    Lu, Rongsheng
    Song, Xuan
    Bao, Chong
    Jiang, Xiaowen
    Ni, Zhonghua
    Yi, Hong
    IEEE SENSORS JOURNAL, 2025, 25 (05) : 8187 - 8195
  • [37] Tibiofibular syndesmosis: High-resolution MRI using a local gradient coil
    Muhle, C
    Frank, LR
    Rand, T
    Ahn, JM
    Yeh, LR
    Trudell, D
    Haghighi, P
    Resnick, D
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (06) : 938 - 944
  • [38] Use of High-Resolution Microscopy Coil MRI for Depicting Orbital Anatomy
    Georgouli, Theodora
    Chang, Bernard
    Nelson, Michael
    James, Teifi
    Tanner, Steven
    Shelley, David
    Saldana, Manuel
    McGonagle, Dennis
    ORBIT-AN INTERNATIONAL JOURNAL ON ORBITAL DISORDERS AND FACIAL RECONSTRUCTIVE SURGERY, 2008, 27 (02): : 107 - 114
  • [39] SNR Variability with Frontal Coil Plate Displacement in 3T Head MRI
    Mathieu, William
    Popovic, Milica
    Farivar, Reza
    2024 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC 2024, 2024, : 131 - 133
  • [40] A comparison of 3T MR imaging of the prostate with and without an endorectal coil
    Ischia, J.
    Co, S.
    Harris, A.
    Kozlowski, P.
    Jones, E.
    Chang, S.
    Goldenberg, L.
    BJU INTERNATIONAL, 2014, 113 : 119 - 120