High-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T: Comparison of surface coil and volume coil

被引:20
|
作者
Bittersohl, Bernd
Huang, Thomas
Schneider, Erika
Biazar, Philip
Winalski, Carl
Lang, Philipp
Yoshioka, Hiroshi
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Cleveland Clin Fdn, Div Radiol, Cleveland, OH 44195 USA
[3] Cleveland Clin Fdn, Dept Radiol, Cleveland, OH 44195 USA
[4] Harvard Univ, Sch Med, Dept Orthoped Surg, Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
high-resolution; magnetic resonance imaging (MRI); triangular fibrocartilage complex; surface coil; 3; tesla;
D O I
10.1002/jmri.21077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate high-resolution MRI of the triangular fibrocartilage complex (TFCC) at 3T using a surface coil (SC) or volume coil (VC). Materials and Methods: MRI was obtained from nine volunteers in the supine position with a 3-inch SC and in prone position with a transmit-receiver wrist VC at 3T. Coronal two-dimensional-gradient echo (2D-GRE) images (TR/TE/FA = 500 msec/15 msec/40 degrees, 1 mm slice-thickness, 60 mm, field of view [FOV], 192 x 256 matrix) and coronal 3D-GRE images (TR/TE/FA = 33 msec/15 msec/10 degrees, 0.8 mm slice-thickness, 80 mm FOV, 256 X 256 matrix) were used. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the TFCC and surrounding structures were measured. For qualitative measurement, visualization of TFCC and intercarpal ligaments was graded. Results: SNR of TFCC, cartilage, and bone marrow on 2D-GRE with SC/VC was as follows: 5.3/5.3 (TFCC), 16.5/14.4 (cartilage), and 3.61/3.96 (bone marrow). 3D-GRE showed similar SNR. Cartilage-TFCC/cartilage-bone marrow CNR were 11.1/12.8 (SC-2D-GRE), 8.8/10.5 (VC-2D-GRE), 14.1/15.5 (SC-3D-GRE), and 11.9/15.0 (VC-3D-GRE). Quantitative values were not significantly different between SC and VC. Visualization of TFCC and intercarpal ligament with SC was superior to that with VC. All structures show higher scores with 3D-GRE imaging compared to 2D-GRE imaging. Conclusion: SC may provide superior qualitative and quantitative results and can be an alternative in case of difficulty in prone position at 3T.
引用
收藏
页码:701 / 707
页数:7
相关论文
共 50 条
  • [21] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020, : 1067 - 1070
  • [22] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [23] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [24] Expected and Unexpected Findings After Prostatectomy: 3T MRI With Surface and Endorectal Coil
    Taneja, R.
    Lee, J.
    Kolokythas, O.
    Dighe, M.
    Dubinsky, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [25] MR IMAGING OF THE SCROTUM WITH A HIGH-RESOLUTION SURFACE COIL
    RHOLL, KS
    LEE, JKT
    LING, D
    HEIKEN, JP
    GLAZER, HS
    RADIOLOGY, 1987, 163 (01) : 99 - 103
  • [26] HIGH-RESOLUTION MRI OF THE TRUE PELVIS USING AN ENDORECTAL COIL
    BONER, JA
    KACL, GM
    TRINKLER, M
    MEYENBERGER, C
    SCHAR, G
    KRESTIN, GP
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (06): : 546 - 554
  • [27] Dynamic changes of the triangular fibrocartilage complex during relation on high resolution MRI
    Nakamura, T
    Yabe, Y
    Horiuchi, Y
    Takayama, S
    HAND SURGERY IN THE NEXT MILLENNIUM, 1999, : 161 - 165
  • [28] High-Resolution MRI Microscopy Coil Assessment of Parotid Masses
    Ginat, Daniel Thomas
    Christoforidis, Gregory
    ENT-EAR NOSE & THROAT JOURNAL, 2019, 98 (09) : 562 - 565
  • [29] Design of Hexagonal RF Surface coil for 3T MRI Scanner by Characteristic Mode Analysis
    Ullah, Rafi
    Venkatesan, Soundarya
    2022 IEEE MICROWAVES, ANTENNAS, AND PROPAGATION CONFERENCE, MAPCON, 2022, : 1100 - 1103
  • [30] A Passive and Conformal Magnetic Metasurface for 3T MRI Birdcage Coil
    Rotundo, Sabrina
    Brizi, Danilo
    Carluccio, Giuseppe
    Lakshmanan, Karthik
    Collins, Christopher M.
    Lattanzi, Riccardo
    Monorchio, Agostino
    2023 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS, ICEAA, 2023, : 222 - 224