摘要
The application of a thin metamaterial (MTM) liner to the RF shield of the magnetic resonance imaging (MRI) system is proposed to improve whole-body imaging compared to conventional "birdcage" body volume coils. The MTM liner facilitates travelling wave (TW) MRI, where the radio-frequency (RF) magnetic field propagates within the MRI bore, which acts as circular waveguide. Full-wave electromagnetic simulations were performed comparing a conventional birdcage coil to a novel MTM liner design in terms of key MR RF performance metrics: transmit efficiency, homogeneity and specific absorption rate (SAR). The designs are compared at 3T (128 MHz) and 4.7T (200MHz), two high-field strengths where the RF field homogeneity and SAR constraints are critical. The ring-structure design of the MTM liner is described and simulations with an empty MRI bore and a homogeneous human body model are performed, including realistic losses for the lumped components used in practical construction. The results show that the MTM liner has a similar mean transmit efficiency, while having reduced 10g averaged local SAR compared to the conventional birdcage.
引用
收藏
页码:1067 / 1070
页数:4
相关论文
共 50 条
  • [1] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [2] Simulation Comparison of Birdcage Coil and Metamaterial Liner for MRI at 3T and 4.7T
    Maunder, Adam
    De Zanche, Nicola
    Iyer, Ashwin K.
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [3] Simulation Design of Incremental Leg Tapered Birdcage Coil for Head Imaging at 4.7T MRI
    Song, Hyunwoo
    Kim, Kyoung-Nam
    Hernandez, Daniel
    APPLIED SCIENCES-BASEL, 2021, 11 (05): : 1 - 7
  • [4] Metamaterial Liner for MRI Excitation-Part 2: Design and Performance at 4.7T
    Maunder, Adam Mitchell
    Iyer, Ashwin K.
    De Zanche, Nicola
    IEEE ACCESS, 2022, 10 : 41678 - 41692
  • [5] A Passive and Conformal Magnetic Metasurface for 3T MRI Birdcage Coil
    Rotundo, Sabrina
    Brizi, Danilo
    Carluccio, Giuseppe
    Lakshmanan, Karthik
    Collins, Christopher M.
    Lattanzi, Riccardo
    Monorchio, Agostino
    2023 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS, ICEAA, 2023, : 222 - 224
  • [6] Double Band-Pass Birdcage RF Coil for Dual Elements NMR Imaging at 4.7T MRI system
    Ahn, Chang Min
    Sheikh, Faisal Ahmad
    Kim, Yeong Cheol
    Kim, Hyun Deok
    2018 IEEE INTERNATIONAL RF AND MICROWAVE CONFERENCE (RFM 2018), 2018, : 189 - 192
  • [7] Double-frequency birdcage volume coils for 4.7T and 7T
    Tomanek, B
    Volotovskyy, V
    Gruwel, MLH
    McKenzie, E
    King, SB
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2005, 26B (01) : 16 - 22
  • [8] Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System
    Lee, Jung-Woo
    Choe, Bo-Young
    Yoon, Sung-Ik
    Choi, Chi-Bong
    Huh, Soon-Nyoung
    JOURNAL OF THE KOREAN MAGNETIC RESONANCE SOCIETY, 2005, 9 (01): : 48 - 60
  • [9] Numerical Design of RF Birdcage Coil without Lumped Elements for MRI 3T System
    Basari
    Priatna, Arwan
    Rahardjo, Eko Tjipto
    Zulkifli, Fitri Yuli
    2015 INTERNATIONAL CONFERENCE QUALITY IN RESEARCH (QIR), 2015, : 90 - 93
  • [10] Impacts of RF Shimming on MRI Induced Heating of Implantable Medical Lead in 3T Birdcage Coil
    Zeng, Qi
    Wang, Qingyan
    Zheng, Jianfeng
    Kainz, Wolfgang
    Chen, Ji
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 1235 - 1237