TIMING PROPERTY OF BGO-DETECTOR

被引:1
|
作者
KORNILOV, NV
SEMENOVA, NN
机构
[1] Institute of Physics and Power Engineering, Obninsk
关键词
D O I
10.1016/0168-9002(93)90753-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The timing property of the BGO-detector for time-of-flight capture cross-section measurement was investigated. Several methods were applied to determine the number eta of photoelectrons per energy unit. The time response functions of the BGO-detector were measured and calculated. One may achieve reasonable agreement between experimental and theoretical results if the light output (eta-value) and the pulse shape of the scintillator are known.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 50 条
  • [21] AN IMPROVED MULTICRYSTAL 2-D BGO DETECTOR FOR PET
    ROGERS, JG
    TAYLOR, AJ
    RAHIMI, MF
    NUTT, R
    ANDREACO, M
    WILLIAMS, CW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) : 1063 - 1068
  • [22] Inter-detector scattering in BGO crystal arrays for PET
    Mesbahi, ME
    Spyrou, NM
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 809 - 817
  • [23] A BGO detector system for studies of neutron capture by radioactive nuclides
    Shcherbakov, O
    Furukata, K
    Nakamura, S
    Harada, H
    Kobayashi, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 517 (1-3): : 269 - 284
  • [24] Performance of the BGO luminosity monitor of the CMD-2 detector
    Budker Inst of Nuclear Physics, Novosibirsk, Russia
    Nucl Instrum Methods Phys Res Sect A, 3 (366-368):
  • [25] Performance of the BGO luminosity monitor of the CMD-2 detector
    Logashenko, IB
    Akhmetshin, RR
    Grigoriev, DN
    Letunov, VS
    Smakhtin, VP
    Yudin, YV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (03): : 366 - 368
  • [26] Analog decoding BGO block detector using circular photomultipliers
    Wong, Wai-Hoi, 1600, IEEE, Piscataway, NJ, United States (42):
  • [27] Status of the endcap BGO calorimeter of the CMD-3 detector
    R. R. Akhmetshin
    D. N. Grigoriev
    V. F. Kazanin
    S. M. Tsaregorodtsev
    Yu. V. Yudin
    Physics of Atomic Nuclei, 2009, 72 : 477 - 481
  • [28] Response of a BGO detector to photon and neutron sources: simulations and measurements
    Vincke, H
    Gschwendtner, E
    Fabjan, CW
    Otto, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 102 - 110
  • [29] Status of the endcap BGO calorimeter of the CMD-3 detector
    Akhmetshin, R. R.
    Grigoriev, D. N.
    Kazanin, V. F.
    Tsaregorodtsev, S. M.
    Yudin, Yu. V.
    PHYSICS OF ATOMIC NUCLEI, 2009, 72 (03) : 477 - 481
  • [30] Advances in radiative capture studies at LUNA with a segmented BGO detector
    Skowronski, J.
    Gesue, R. M.
    Boeltzig, A.
    Ciani, G. F.
    Piatti, D.
    Rapagnani, D.
    Aliotta, M.
    Ananna, C.
    Barile, F.
    Bemmerer, D.
    Best, A.
    Broggini, C.
    Bruno, C. G.
    Caciolli, A.
    Campostrini, M.
    Cavanna, F.
    Colombetti, P.
    Compagnucci, A.
    Corvisiero, P.
    Csedreki, L.
    Davinson, T.
    Depalo, R.
    Di Leva, A.
    Elekes, Z.
    Ferraro, F.
    Formicola, A.
    Fulop, Zs
    Gervino, G.
    Guglielmetti, A.
    Gustavino, C.
    Gyurky, Gy
    Imbriani, G.
    Junker, M.
    Lugaro, M.
    Marigo, P.
    Masha, E.
    Menegazzo, R.
    Paticchio, V
    Perrino, R.
    Prati, P.
    Rigato, V
    Schiavulli, L.
    Sidhu, R. S.
    Straniero, O.
    Szucs, T.
    Zavatarelli, S.
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2023, 50 (04)