AN IMPROVED MULTICRYSTAL 2-D BGO DETECTOR FOR PET

被引:27
|
作者
ROGERS, JG
TAYLOR, AJ
RAHIMI, MF
NUTT, R
ANDREACO, M
WILLIAMS, CW
机构
[1] UNIV MASHHAD,DEPT PHYS,MASHHAD,IRAN
[2] SIEMENS,CTI,KNOXVILLE,TN 37933
关键词
D O I
10.1109/23.159760
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We evaluate and compare two new 2-D array detectors for PET. Both consist of an 8 x 8 array of small BGO crystals coupled to a 2 x 2 array of photomultiplier tubes. The depth of the crystals is 3 cm in one detector and 2 cm in the other. The 2 cm detector is obviously superior in terms of material costs, but is also superior in energy resolution per crystal, and in its ability to clearly identify the crystal containing the primary interaction. We present a flexible and robust algorithm for crystal identification in such array detectors. The prospect of obtaining still better spatial resolution from such block detectors, with increased numbers of crystals, is discussed.
引用
收藏
页码:1063 / 1068
页数:6
相关论文
共 50 条
  • [1] A MULTICRYSTAL 2-DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY
    CASEY, ME
    NUTT, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 460 - 463
  • [2] A depth encoding in multicrystal detector for PET
    Murayama, H
    Ishibashi, H
    Uchida, U
    Omura, T
    Yamashita, T
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1037 - 1041
  • [3] MULTICRYSTAL TWO DIMENSIONAL BGO DETECTOR SYSTEM FOR POSITRON EMISSION TOMOGRAPHY.
    Casey, M.E.
    Nutt, R.
    IEEE Transactions on Nuclear Science, 1985, NS-33 (01)
  • [4] Performance studies of a depth encoding multicrystal detector for PET
    Moisan, C
    Tsang, G
    Rogers, JG
    Hoskinson, EM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1926 - 1931
  • [5] Performance studies of a depth encoding multicrystal detector for PET
    Moisan, C
    Tsang, G
    Rogers, JG
    Hoskinson, EM
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1064 - 1068
  • [6] Performance studies of a depth encoding multicrystal detector for PET
    Moisan, C.
    Tsang, G.
    Rogers, J.G.
    Hoskinson, E.M.
    IEEE Transactions on Nuclear Science, 1996, 43 (3 pt 2): : 1926 - 1931
  • [7] Computer simulation for design of depth encoding multicrystal detector for PET
    Haneishi, H
    Nishiya, S
    Miyake, Y
    Murayama, H
    Omura, T
    Ishibashi, H
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1207 - 1211
  • [8] Monte Carlo simulation for depth encoding multicrystal detector for PET
    Haneishi, H
    Yamada, A
    Takagi, K
    Murayama, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1993 - 1996
  • [9] Improved Multitrack Detection With Hybrid 2-D Equalizer and Modified Viterbi Detector
    Wang, Yao
    Kumar, B. V. K. Vijaya
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (10)
  • [10] An improved quadrant-sharing BGO detector for a low cost rodent-research PET (RRPET)
    Wong, WH
    Xie, S
    Ramirez, R
    Kim, S
    Li, H
    Zhang, Y
    Uribe, J
    Wang, Y
    Baghaei, H
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3407 - 3411