AN IMPROVED MULTICRYSTAL 2-D BGO DETECTOR FOR PET

被引:27
|
作者
ROGERS, JG
TAYLOR, AJ
RAHIMI, MF
NUTT, R
ANDREACO, M
WILLIAMS, CW
机构
[1] UNIV MASHHAD,DEPT PHYS,MASHHAD,IRAN
[2] SIEMENS,CTI,KNOXVILLE,TN 37933
关键词
D O I
10.1109/23.159760
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We evaluate and compare two new 2-D array detectors for PET. Both consist of an 8 x 8 array of small BGO crystals coupled to a 2 x 2 array of photomultiplier tubes. The depth of the crystals is 3 cm in one detector and 2 cm in the other. The 2 cm detector is obviously superior in terms of material costs, but is also superior in energy resolution per crystal, and in its ability to clearly identify the crystal containing the primary interaction. We present a flexible and robust algorithm for crystal identification in such array detectors. The prospect of obtaining still better spatial resolution from such block detectors, with increased numbers of crystals, is discussed.
引用
收藏
页码:1063 / 1068
页数:6
相关论文
共 50 条
  • [21] Preliminary evaluation of four-layer BGO DOI-detector for PET
    Inadama, N
    Murayama, H
    Yamaya, T
    Kitamura, K
    Yamashita, T
    Kawai, H
    Tsuda, T
    Sato, M
    Ono, Y
    Hamamoto, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 30 - 34
  • [22] A pentagon photomultiplier-quadrant-sharing BGO detector for a rodent research PET
    Xie, SP
    Ramirez, R
    Liu, YQ
    Xing, T
    Uribe, J
    Li, HD
    Wang, Y
    Baghaei, H
    Kim, S
    Wong, WH
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1800 - 1804
  • [23] PET Detector Block with DOI Capabilities Based on a Large Monolithic BGO Crystal
    Gonzalez-Montoro, Andrea
    Majewski, Stan
    Sanchez, Filomeno
    Benlloch, Jose M.
    Zanettini, Silvia
    Gonzalez, Antonio J.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [24] Improved damage model of 2-D delamination
    Yang Gang
    Zhang Aifeng
    Hu Weiping
    Huang Baozong
    FRACTURE AND DAMAGE MECHANICS V, PTS 1 AND 2, 2006, 324-325 : 439 - +
  • [25] 2-D or not 2-D?
    Rao, SS
    FORBES, 1999, 164 (12): : 234 - 234
  • [26] Noise characteristics of 3-D and 2-D PET images
    Pajevic, S
    Daube-Witherspoon, ME
    Bacharach, SL
    Carson, RE
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (01) : 9 - 23
  • [27] Improved BER Performance With Rotated Head Array and 2-D Detector in Two-Dimensional Magnetic Recording
    Wang, Yao
    Yuan, Bo
    Parhi, Keshab K.
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (07)
  • [28] 2-D scintillation position-sensitive neutron detector
    De Lurgio, Patrick M.
    Farrar, Kelly A.
    Kreps, Andrew S.
    Madden, Timothy J.
    Naday, Istvan
    Weizeorick, John T.
    Hammonds, John P.
    Miller, Martha E.
    Schultz, Arthur J.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 648 - 653
  • [29] 2-D POSITION-SENSITIVE SCINTILLATION DETECTOR FOR NEUTRONS
    STRAUSS, MG
    BRENNER, R
    LYNCH, FJ
    MORGAN, CB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 800 - 806
  • [30] A 2-D MSGC-based imaging detector for neutrons
    Bateman, JE
    Derbyshire, GE
    Duxbury, DM
    Marsh, AS
    Rhodes, NJ
    Schooneveld, EM
    Spill, EJ
    Stephenson, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1693 - 1697