TIMING PROPERTY OF BGO-DETECTOR

被引:1
|
作者
KORNILOV, NV
SEMENOVA, NN
机构
[1] Institute of Physics and Power Engineering, Obninsk
关键词
D O I
10.1016/0168-9002(93)90753-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The timing property of the BGO-detector for time-of-flight capture cross-section measurement was investigated. Several methods were applied to determine the number eta of photoelectrons per energy unit. The time response functions of the BGO-detector were measured and calculated. One may achieve reasonable agreement between experimental and theoretical results if the light output (eta-value) and the pulse shape of the scintillator are known.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 50 条
  • [31] Performance of the BGO endcap calorimeter of the CMD-3 detector
    Akhmetshin, R. R.
    Grigoriev, D. N.
    Kazanin, V. F.
    Kuzmenko, A. E.
    Yudin, Yu. V.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [32] The calibration and electron energy reconstruction of the BGO ECAL of the DAMPE detector
    Zhang, Zhiyong
    Wang, Chi
    Dong, Jianing
    Wei, Yifeng
    Wen, Sicheng
    Zhang, Yunlong
    Li, Zhiying
    Feng, Changqing
    Gao, Shanshan
    Shen, ZhongTao
    Zhang, Deliang
    Zhang, Junbin
    Wang, Qi
    Ma, SiYuan
    Yang, Di
    Jiang, Di
    Chen, Dengyi
    Hu, Yiming
    Huang, Guangshun
    Wang, Xiaolian
    Xu, Zizong
    Liu, Shubin
    An, Qi
    Gong, Yizhong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 836 : 98 - 104
  • [33] Precision Timing with the CMS MIP Timing Detector
    Bornheim, Adi
    EUROPEAN PHYSICAL SOCIETY CONFERENCE ON HIGH ENERGY PHYSICS, EPS-HEP2019, 2020,
  • [34] Precision Timing with the CMS MIP Timing Detector
    Pena, Cristian H.
    18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162
  • [35] INITIAL CHARACTERIZATION OF A POSITION-SENSITIVE PHOTODIODE BGO DETECTOR FOR PET
    DERENZO, SE
    MOSES, WW
    JACKSON, HG
    TURKO, BT
    CAHOON, JL
    GEYER, AB
    VULETICH, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1084 - 1089
  • [36] FAST COINCIDENCE TIMING FOR POSITRON EMISSION TOMOGRAPHY WITH SMALL BGO CRYSTALS
    SANK, VJ
    BROOKS, RA
    FRIAUF, WS
    YEE, W
    DICHIRO, G
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (05) : P95 - P95
  • [37] STATUS OF BGO-AVALANCHE PHOTODIODE DETECTORS FOR SPECTROSCOPIC AND TIMING MEASUREMENTS
    LECOMTE, R
    MARTEL, C
    CARRIER, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02): : 585 - 597
  • [38] PERFORMANCE OF A SEGMENTED GE/BGO DETECTOR AS AN ESCAPE SUPPRESSED AND PAIR SPECTROMETER
    EMLING, H
    AZGUI, F
    DATHER, M
    DOEBEREINER, S
    GREIN, H
    MICHEL, C
    WOLLERSHEIM, HJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (2-3): : 320 - 324
  • [39] High-energy calibration of a BGO detector of the GLAST Burst Monitor
    von Kienlin, Andreas
    Fishman, Gerald J.
    Briggs, Michael S.
    Godfrey, Gary L.
    Steinle, Helmut
    First GLAST Symposium, 2007, 921 : 576 - 577
  • [40] Testing and assessment of a large BGO detector for beach monitoring of radioactive particles
    van der Graaf, E. R.
    Rigollet, C.
    Maleka, P. P.
    Jones, D. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 575 (03): : 507 - 518