ANALYSIS OF HIGH-FREQUENCY ROTATIONAL ANGIOPLASTY-INDUCED ECHO CONTRAST

被引:9
|
作者
ZOTZ, R
STAHR, P
ERBEL, R
AUTH, D
MEYER, J
机构
[1] II Medical Clinic, Johannes Gutenberg University, Mainz
来源
关键词
ROTABLATOR; CONTRAST ECHOCARDIOGRAPHY; MICROCAVITATION; BERNOULLI EQUATION;
D O I
10.1002/ccd.1810220215
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During high-frequency rotational angioplasty (HFRA), myocardial contrast enhancement (echo contrast) was observed by means of two-dimensional echocardiography. In order to evaluate the echo contrast produced by HFRA, an in vitro experimental model was built using a cylinder with the HFRA catheter scanned in a water bath. The cylinder was filled with blood, mineral water, and distilled water. With a 2.5-MHz transducer, echograms were recorded and analyzed by video intensitometer, and the maximum intensity IU(max) and persistence time P were calculated. Rotation frequencies of 20,000-200,000 rpm with 2.0-mm burrs and times of 10 s were tested. In another model, hyperbaric conditions for the same media were produced. The influence of debris from arterioscleroic plaque and of hematocrit on echo contrast intensity were also analyzed. The effect of HFRA on hemolysis (LDH, free hemoglobin) within 10 s and temperature were also measured. The contrast effect was transient, depending on the rotation frequency. In blood, it appeared at 20,000 rpm (IU(max) at 200,000 rpm: 237 IU), in mineral water at 40,000 rpm (IU(max) 165 IU), and in distilled water at 80,000 rpm (IU(max) 72 IU). Persistence time was measured up to about a half-minute. Echo contrast production was reduced at 0.5 bar and fully suppressed at 2.5 bar. Debris increased contrast intensity from about 219 IU to 225 IU (at 160,000 rpm). In blood IU(max) decreased from 227 IU to 97 IU by lowering the hematocrit from 44.2% to 3.6%. Free hemoglobin increased up to 4,890 mg/L (baseline value 38 mg/L), LDH increased up to 680 U/L (baseline value 100 U/L). Temperature rose only by 1.0-degrees-C within 10 s of rotation, whereas an increase up to 7.7-degrees-C occurred within 40 s. The observed echocontrast seems to be due to microcavitation, depending on the fluid, frequency, and pressure.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [41] METHODS FOR HIGH-FREQUENCY SIGNAL ANALYSIS
    JONDRAL, F
    AEU-ARCHIV FUR ELEKTRONIK UND UBERTRAGUNGSTECHNIK-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 1987, 41 (03): : 149 - 155
  • [42] ANALYSIS OF HIGH-FREQUENCY INVERTER CIRCUIT
    REVANKAR, GN
    GADAG, SA
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS AND CONTROL INSTRUMENTATION, 1973, IE20 (03): : 178 - 182
  • [43] ANALYSIS OF MOS HIGH-FREQUENCY CHARACTERISTICS
    KARAKHANYAN, ER
    SHILIN, VA
    NOSOV, YR
    RADIOTEKHNIKA I ELEKTRONIKA, 1972, 17 (04): : 856 - +
  • [44] High-frequency transistor amplifier analysis
    Nayaka, CSM
    IEEE TRANSACTIONS ON EDUCATION, 2006, 49 (01) : 58 - 60
  • [45] HIGH-FREQUENCY TECHNIQUES FOR ANTENNA ANALYSIS
    PATHAK, PH
    PROCEEDINGS OF THE IEEE, 1992, 80 (01) : 44 - 65
  • [46] STABLE APPARATUS FOR HIGH-FREQUENCY ANALYSIS
    ISHII, K
    HAYASHI, S
    FUJIWARA, S
    ANALYTICAL CHEMISTRY, 1959, 31 (09) : 1586 - 1589
  • [47] ANALYSIS OF HIGH-FREQUENCY RESISTANCE IN TRANSFORMERS
    SAKAKIBARA, K
    MURAKAMI, N
    PESC 89 RECORD, VOLS 1 AND 2: 20TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, 1989, : 618 - 624
  • [48] Phase analysis in high-frequency oscillation
    Lee, S
    Blowes, R
    Milner, AD
    MEDICAL ENGINEERING & PHYSICS, 1998, 20 (06) : 452 - 457
  • [49] HIGH-FREQUENCY METHODS IN ORGANIC ANALYSIS
    ZARINSKII, VA
    GUREV, IA
    INDUSTRIAL LABORATORY, 1963, 29 (10): : 1267 - 1272
  • [50] Effect of rocket flame on high-frequency echo and its frequency energy agglomerated detection method
    Wu Xia
    Chen Jian-Wen
    Bao Zheng
    Guo De-Yang
    ACTA PHYSICA SINICA, 2014, 63 (11)