During high-frequency rotational angioplasty (HFRA), myocardial contrast enhancement (echo contrast) was observed by means of two-dimensional echocardiography. In order to evaluate the echo contrast produced by HFRA, an in vitro experimental model was built using a cylinder with the HFRA catheter scanned in a water bath. The cylinder was filled with blood, mineral water, and distilled water. With a 2.5-MHz transducer, echograms were recorded and analyzed by video intensitometer, and the maximum intensity IU(max) and persistence time P were calculated. Rotation frequencies of 20,000-200,000 rpm with 2.0-mm burrs and times of 10 s were tested. In another model, hyperbaric conditions for the same media were produced. The influence of debris from arterioscleroic plaque and of hematocrit on echo contrast intensity were also analyzed. The effect of HFRA on hemolysis (LDH, free hemoglobin) within 10 s and temperature were also measured. The contrast effect was transient, depending on the rotation frequency. In blood, it appeared at 20,000 rpm (IU(max) at 200,000 rpm: 237 IU), in mineral water at 40,000 rpm (IU(max) 165 IU), and in distilled water at 80,000 rpm (IU(max) 72 IU). Persistence time was measured up to about a half-minute. Echo contrast production was reduced at 0.5 bar and fully suppressed at 2.5 bar. Debris increased contrast intensity from about 219 IU to 225 IU (at 160,000 rpm). In blood IU(max) decreased from 227 IU to 97 IU by lowering the hematocrit from 44.2% to 3.6%. Free hemoglobin increased up to 4,890 mg/L (baseline value 38 mg/L), LDH increased up to 680 U/L (baseline value 100 U/L). Temperature rose only by 1.0-degrees-C within 10 s of rotation, whereas an increase up to 7.7-degrees-C occurred within 40 s. The observed echocontrast seems to be due to microcavitation, depending on the fluid, frequency, and pressure.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [31] Ultrasound: high-frequency, 3D and contrast agents
    Rizzatto, G
    EUROPEAN JOURNAL OF CANCER, 2002, 38 : S47 - S47
  • [32] High-frequency contrast harmonic imaging of ophthalmic tumor perfusion
    Schlottmann, K
    Fuchs-Koelwel, B
    Demmler-Hackenberg, M
    Gabel, VP
    Schölmerich, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 574 - 578
  • [33] Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
    Denbeigh, Janet M.
    Nixon, Brian A.
    Puri, Mira C.
    Foster, F. Stuart
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2015, (97):
  • [34] High-frequency, nonlinear flow imaging of microbubble contrast agents
    Goertz, DE
    Needles, A
    Burns, PN
    Foster, FS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (03) : 495 - 502
  • [35] High-frequency ultrasonic detection of thrombi with a targeted contrast system
    Lanza, GM
    Wallace, KD
    Fischer, SE
    Christy, DH
    Scott, MJ
    Trousil, RL
    Cacheris, WP
    Miller, JG
    Gaffney, PJ
    Wickline, SA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (06): : 863 - 870
  • [36] Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current Transducer
    Jiang, Jun
    Zhao, Mingxin
    Zhang, Chaohai
    Chen, Min
    Liu, Haojun
    Albarracin, Ricardo
    ENERGIES, 2018, 11 (08)
  • [37] Automatic analysis of the high-frequency electrocardiogram
    Hong, YL
    Zhi, GW
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 214 - 215
  • [38] ANALYSIS OF HIGH-FREQUENCY RESPONSE OF A SQUID
    CALLEGARI, A
    DEAVER, BS
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (03): : 359 - 359
  • [39] Cryptocurrencies and stablecoins: a high-frequency analysis
    Emilio Barucci
    Giancarlo Giuffra Moncayo
    Daniele Marazzina
    Digital Finance, 2022, 4 (2-3): : 217 - 239
  • [40] HIGH-FREQUENCY ANALYSIS OF THE ELLIPTICUS ANTENNA
    YOUNAN, NH
    COX, BL
    TAYLOR, CD
    PRATHER, WD
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1994, 36 (04) : 394 - 398