ANALYSIS OF HIGH-FREQUENCY ROTATIONAL ANGIOPLASTY-INDUCED ECHO CONTRAST

被引:9
|
作者
ZOTZ, R
STAHR, P
ERBEL, R
AUTH, D
MEYER, J
机构
[1] II Medical Clinic, Johannes Gutenberg University, Mainz
来源
关键词
ROTABLATOR; CONTRAST ECHOCARDIOGRAPHY; MICROCAVITATION; BERNOULLI EQUATION;
D O I
10.1002/ccd.1810220215
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
During high-frequency rotational angioplasty (HFRA), myocardial contrast enhancement (echo contrast) was observed by means of two-dimensional echocardiography. In order to evaluate the echo contrast produced by HFRA, an in vitro experimental model was built using a cylinder with the HFRA catheter scanned in a water bath. The cylinder was filled with blood, mineral water, and distilled water. With a 2.5-MHz transducer, echograms were recorded and analyzed by video intensitometer, and the maximum intensity IU(max) and persistence time P were calculated. Rotation frequencies of 20,000-200,000 rpm with 2.0-mm burrs and times of 10 s were tested. In another model, hyperbaric conditions for the same media were produced. The influence of debris from arterioscleroic plaque and of hematocrit on echo contrast intensity were also analyzed. The effect of HFRA on hemolysis (LDH, free hemoglobin) within 10 s and temperature were also measured. The contrast effect was transient, depending on the rotation frequency. In blood, it appeared at 20,000 rpm (IU(max) at 200,000 rpm: 237 IU), in mineral water at 40,000 rpm (IU(max) 165 IU), and in distilled water at 80,000 rpm (IU(max) 72 IU). Persistence time was measured up to about a half-minute. Echo contrast production was reduced at 0.5 bar and fully suppressed at 2.5 bar. Debris increased contrast intensity from about 219 IU to 225 IU (at 160,000 rpm). In blood IU(max) decreased from 227 IU to 97 IU by lowering the hematocrit from 44.2% to 3.6%. Free hemoglobin increased up to 4,890 mg/L (baseline value 38 mg/L), LDH increased up to 680 U/L (baseline value 100 U/L). Temperature rose only by 1.0-degrees-C within 10 s of rotation, whereas an increase up to 7.7-degrees-C occurred within 40 s. The observed echocontrast seems to be due to microcavitation, depending on the fluid, frequency, and pressure.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [21] Radio frequency spectral analysis of attenuated echo contrast signals
    Asanuma, T
    Belohlavek, M
    Greenleaf, JF
    Seward, JB
    CIRCULATION, 2000, 102 (18) : 541 - 541
  • [22] INDUCED RADIATION OF PHONONS OF HIGH-FREQUENCY
    KOVALEV, GV
    FIZIKA TVERDOGO TELA, 1978, 20 (10): : 3133 - 3135
  • [23] High-frequency performance analysis and optimize design of high-frequency power relay
    Xu, Le
    Chen, Guofeng
    Song, Jiangzhu
    Zhai, Guofu
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2013, 28 (SUPPL.1): : 383 - 388
  • [24] A HIGH-FREQUENCY ANALYSIS OF RADOME-INDUCED RADAR POINTING ERROR
    BURKS, DG
    GRAF, ER
    FAHEY, MD
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1982, 30 (05) : 947 - 955
  • [25] Processing of high-frequency multibeam echo sounder data for seafloor characterization
    Hellequin, L
    Boucher, JM
    Lurton, X
    IEEE JOURNAL OF OCEANIC ENGINEERING, 2003, 28 (01) : 78 - 89
  • [26] An extended surface target for high-frequency multibeam echo sounder calibration
    Heaton, John L.
    Rice, Glen
    Weber, Thomas C.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2017, 141 (04): : EL388 - EL394
  • [27] MEASUREMENTS OF ACOUSTIC CORRELATION IN THE OCEAN WITH A HIGH-FREQUENCY ECHO-SOUNDER
    FARMER, DM
    CRAWFORD, GB
    NATURE, 1983, 301 (5902) : 698 - 700
  • [28] HIGH-FREQUENCY PULSE ECHO MEASUREMENTS OF CERAMICS AND THIN-LAYERS
    KHURIYAKUB, BT
    KINO, GS
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1977, 24 (02): : 138 - 139
  • [29] DELINEATION OF CONTRACTILE HETEROGENEITY BY HIGH-FREQUENCY EPICARDIAL ECHO MAPPING IN MAN
    MACOVIAK, JA
    LIKOFF, M
    REICHEK, N
    STJOHNSUTTON, M
    WETSTEIN, L
    STEPHENSON, LW
    JOSEPHSON, M
    MOORE, EN
    HARKEN, AH
    SURGICAL FORUM, 1981, 32 : 276 - 278
  • [30] COMPARISON OF HIGH-FREQUENCY CONTRAST-ENHANCED ULTRASOUND WITH CONVENTIONAL HIGH-FREQUENCY ULTRASOUND IN GUIDING PLEURAL LESION BIOPSY
    Ye, F. U. Y. O. N. G.
    Yang, Y. U. W. E. N.
    Liu, J. I. A. N. H. U. A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (08): : 1420 - 1428