IMPROVEMENTS AND RECENT PERFORMANCE OF A DOUBLE-CRYSTAL MONOCHROMATOR FOR A SOFT-X-RAY UNDULATOR AT THE PHOTON FACTORY

被引:23
|
作者
KITAJIMA, Y
TAKATA, Y
TOYOSHIMA, A
MAEZAWA, H
机构
[1] Photon Factory, National Laboratory for High Energy Physics, Tsukuba, Ibaraki 305
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1142636
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cooling system for the first crystal of a double-crystal monochromator for a 60-period soft x-ray undulator at the Photon Factory is newly designed and installed. In order to keep smooth movements of the original mechanism in a high-vacuum chamber, heat pipes and a liquid-metal bath are utilized. A fear for melting of an InSb crystal and the instability caused by warming of mechanisms have vanished and significantly improved energy resolution of 5000-8000 is achieved by Si crystals for high photon flux of about 10(11) photons/s in a beam size of 3 x 3 mm2 at a sample position with the cooling system.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 50 条
  • [31] A 10-M GRAZING-INCIDENCE MONOCHROMATOR FOR HIGH-RESOLUTION SOFT-X-RAY SPECTROSCOPY AT THE PHOTON FACTORY
    MAEZAWA, H
    NAKAI, S
    MITANI, S
    NODA, H
    NAMIOKA, T
    SASAKI, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 310 - 313
  • [32] STATUS OF A BEAMLINE FOR A 60-PERIOD SOFT-X-RAY UNDULATOR IN THE LOW EMITTANCE OPERATION OF THE PHOTON FACTORY STORAGE RING
    MAEZAWA, H
    TOYOSHIMA, A
    KAGOSHIMA, Y
    MORI, K
    ISHIKAWA, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 1889 - 1892
  • [33] X-RAY MICROSCOPY WITH THE NSLS SOFT-X-RAY UNDULATOR
    KIRZ, J
    ADE, H
    ANDERSON, E
    ATTWOOD, D
    BUCKLEY, C
    HELLMAN, S
    HOWELLS, M
    JACOBSEN, C
    KERN, D
    LINDAAS, S
    MCNULTY, I
    OVERSLUIZEN, M
    RARBACK, H
    RIVERS, M
    ROTHMAN, S
    SAYRE, D
    SHU, D
    PHYSICA SCRIPTA, 1990, T31 : 12 - 17
  • [34] Improvement of the performance of sagittally focusing double-crystal monochromator
    Fu, Xuan
    Zhou, Renkui
    Zhou, Sizhong
    Guangzi Xuebao/Acta Photonica Sinica, 2000, 29 (04): : 372 - 375
  • [35] A low-cost and flexible double-crystal monochromator for an x-ray beamline
    Hwang, CS
    Lin, FY
    Lee, CH
    Yu, KL
    Hsieh, CH
    Tseng, PK
    Lin, JT
    Pong, WF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (03): : 1230 - 1235
  • [36] Double crystal monochromator for x-ray undulator beamline at the PF-AR
    Kawata, H
    Mori, T
    Adachi, H
    Matsugaki, N
    Koyama, A
    Nomura, M
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 663 - 666
  • [37] A simple formula to calculate the x-ray flux after a double-crystal monochromator
    del Río, MS
    Mathon, O
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY AND NEUTRON OPTICS, 2004, 5536 : 157 - 164
  • [38] Ultrasound adjustable Laue-Laue double-crystal x-ray monochromator
    Polikarpov, I
    Panov, VV
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (16) : 2083 - 2086
  • [39] PRESENT STATUS AND FUTURE PLAN OF SOFT-X-RAY MICROSCOPY AT THE PHOTON FACTORY
    KAGOSHIMA, Y
    MIYAHARA, T
    ANDO, M
    AOKI, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 605 - 608
  • [40] Low-cost and flexible double-crystal monochromator for an x-ray beamline
    Hwang, C.S.
    Lin, F.Y.
    Lee, Chih-Hao
    Yu, Kuan-Li
    Hsieh, C.H.
    Tseng, P.K.
    Lin, J.T.
    Pong, W.F.
    Review of Scientific Instruments, 1998, 69 (03):