IMPROVEMENTS AND RECENT PERFORMANCE OF A DOUBLE-CRYSTAL MONOCHROMATOR FOR A SOFT-X-RAY UNDULATOR AT THE PHOTON FACTORY

被引:23
|
作者
KITAJIMA, Y
TAKATA, Y
TOYOSHIMA, A
MAEZAWA, H
机构
[1] Photon Factory, National Laboratory for High Energy Physics, Tsukuba, Ibaraki 305
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1142636
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cooling system for the first crystal of a double-crystal monochromator for a 60-period soft x-ray undulator at the Photon Factory is newly designed and installed. In order to keep smooth movements of the original mechanism in a high-vacuum chamber, heat pipes and a liquid-metal bath are utilized. A fear for melting of an InSb crystal and the instability caused by warming of mechanisms have vanished and significantly improved energy resolution of 5000-8000 is achieved by Si crystals for high photon flux of about 10(11) photons/s in a beam size of 3 x 3 mm2 at a sample position with the cooling system.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 50 条
  • [21] A GRAPHITE DOUBLE-CRYSTAL MONOCHROMATOR FOR X-RAY SYNCHROTRON RADIATION
    HOHLWEIN, D
    SIDDONS, DP
    HASTINGS, JB
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1988, 21 (06) : 911 - 915
  • [22] Diamond double-crystal monochromator for SPring-8 undulator beamlines
    Yabashi, M.
    Goto, S.
    Shimizu, Y.
    Tamasaku, K.
    Yamazaki, H.
    Yoda, Y.
    Suzuki, M.
    Ohishi, Y.
    Yamamoto, M.
    Ishikawa, T.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 922 - +
  • [23] A DOUBLE-CRYSTAL SOFT X-RAY SPECTROMETER
    SUONINEN, E
    KARRAS, M
    LEVOSKA, J
    ACTA POLYTECHNICA SCANDINAVICA-PHYSICS INCLUDING NUCLEONICS SERIES, 1970, (71): : 1 - &
  • [24] Ray traces of an arbitrarily deformed double-crystal Laue X-ray monochromator
    Sutter, John P.
    Connolley, Thomas
    Drakopoulos, Michael
    Hill, Timothy P.
    Sharp, Doug W.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS III, 2008, 7077
  • [25] Design and performance of a soft X-ray double crystal monochromator at HSRC
    Yagi, S
    Kutluk, G
    Matsui, T
    Matano, A
    Hiraya, A
    Hashimoto, E
    Taniguchi, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 723 - 726
  • [26] HIGH-VACUUM 2 CRYSTAL SOFT-X-RAY MONOCHROMATOR
    LEMONNIER, M
    COLLET, O
    DEPAUTEX, C
    ESTEVA, JM
    RAOUX, D
    NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (01): : 109 - 111
  • [27] A DOUBLE-CRYSTAL X-RAY MONOCHROMATOR IN ANTIPARALLEL POSITION WITH A SAGITTALLY BENT CRYSTAL
    HRDY, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08): : 2207 - 2210
  • [28] A SOFT-X-RAY BEAM LINE (BL13C) AT THE PHOTON FACTORY WITH A CEM USING UNDULATOR RADIATION
    MATSUBAYASHI, N
    SHIMADA, H
    TANAKA, K
    SATO, T
    YOSHIMURA, Y
    NISHIJIMA, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1363 - 1366
  • [29] CHROMATICITY CORRECTION FOR THE VUV AND SOFT-X-RAY RING AT THE PHOTON FACTORY
    KOBAYASHI, Y
    KAMIYA, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (02): : 1726 - 1730
  • [30] A DOUBLE CRYSTAL MONOCHROMATOR FOR THE PHOTON FACTORY WIGGLER BEAMLINE
    KAWATA, H
    ANDO, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 368 - 372