IMPROVEMENTS AND RECENT PERFORMANCE OF A DOUBLE-CRYSTAL MONOCHROMATOR FOR A SOFT-X-RAY UNDULATOR AT THE PHOTON FACTORY

被引:23
|
作者
KITAJIMA, Y
TAKATA, Y
TOYOSHIMA, A
MAEZAWA, H
机构
[1] Photon Factory, National Laboratory for High Energy Physics, Tsukuba, Ibaraki 305
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 01期
关键词
D O I
10.1063/1.1142636
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A cooling system for the first crystal of a double-crystal monochromator for a 60-period soft x-ray undulator at the Photon Factory is newly designed and installed. In order to keep smooth movements of the original mechanism in a high-vacuum chamber, heat pipes and a liquid-metal bath are utilized. A fear for melting of an InSb crystal and the instability caused by warming of mechanisms have vanished and significantly improved energy resolution of 5000-8000 is achieved by Si crystals for high photon flux of about 10(11) photons/s in a beam size of 3 x 3 mm2 at a sample position with the cooling system.
引用
收藏
页码:886 / 889
页数:4
相关论文
共 50 条
  • [41] NEW MONOCHROMATOR DESIGNS FOR THE SOFT-X-RAY RANGE
    TATCHYN, R
    LINDAU, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (1-2): : 163 - 173
  • [42] SOFT-X-RAY EMISSION SPECTROMETER FOR UNDULATOR RADIATION
    SHIN, S
    AGUI, A
    FUJISAWA, M
    TEZUKA, Y
    ISHII, T
    HIRAI, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1584 - 1586
  • [43] NEW EXPERIMENTS USING A SOFT-X-RAY UNDULATOR
    EBERHARDT, W
    PLUMMER, EW
    CHEN, CT
    CARR, R
    FORD, WK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 825 - 834
  • [44] Improved multilayer monochromator for the soft-x-ray domain
    Lab. de Chim. Phys. - Matiere Rayon, Univ. Pierre et Marie Curie, Paris, France
    不详
    不详
    不详
    不详
    Optics and Photonics News, 2001, 12 (12):
  • [45] DETERMINATION OF GLITCHES IN SOFT-X-RAY MONOCHROMATOR CRYSTALS
    VANDERLAAN, G
    THOLE, BT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (2-3): : 515 - 521
  • [46] AN UNDULATOR SOURCE BEAMLINE FOR SOFT-X-RAY IMAGING
    RARBACK, H
    KRINSKY, S
    MORTAZAVI, P
    SHU, D
    KIRZ, J
    JACOBSEN, C
    HOWELLS, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 159 - 162
  • [47] PERFORMANCE OF LAYERED SYNTHETIC MICROSTRUCTURES IN MONOCHROMATOR APPLICATIONS IN THE SOFT-X-RAY REGION
    PIANETTA, P
    BARBEE, TW
    REDAELLI, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 352 - 355
  • [48] VERSATILE DOUBLE-CRYSTAL FIXED EXIT MONOCHROMATOR FOR X-RAY SYNCHROTRON-RADIATION
    RAMANATHAN, M
    MONTANO, PA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02): : 1754 - 1756
  • [49] Possibility of X-ray pulse compression using an asymmetric or inclined double-crystal monochromator
    Hrdy, Jaromir
    Oberta, Peter
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 550 - 554
  • [50] APPARATUS FOR CHARACTERIZING THE VUV AND SOFT-X-RAY OPTICAL-ELEMENTS AT THE PHOTON FACTORY
    MITANI, S
    NAMIOKA, T
    YANAGIHARA, M
    YAMASHITA, K
    FUJITA, J
    MORITA, S
    HARADA, T
    SASAKI, T
    SATO, S
    MIYAHARA, T
    KOIDE, T
    MIKUNI, A
    OKAMOTO, W
    MAEZAWA, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2216 - 2218