摘要
At the Photon Factory a project of a transmission soft x-ray microscope using zone plates as imaging elements has been initiated since 1986 at the beam line BL2B which is for the linearly polarized undulator radiation. The prototype version was built and its performance was measured in 1987. In order to proceed with our project we have reconstructed it capable of the spatial resolution better than 100 nm. Further, we have just started a new plan of microscopy at the station BL28 which introduces the circularly polarized soft x-ray/vacuum ultraviolet light emitted from a helical undulator. Both the present status at BL2B and a future plan at BL28 are described.
引用
收藏
页码:605 / 608
页数:4
相关论文
共 50 条
  • [1] SOFT-X-RAY MICROSCOPE AT THE UNDULATOR BEAMLINE OF THE PHOTON FACTORY
    KAGOSHIMA, Y
    AOKI, S
    KAKUCHI, M
    SEKIMOTO, M
    MAEZAWA, H
    HYODO, K
    ANDO, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2448 - 2451
  • [2] CURRENT STATUS OF 10-M GIM FOR SOFT-X-RAY UNDULATOR AT THE PHOTON FACTORY
    YAGISHITA, A
    MASUI, S
    TOYOSHIMA, T
    MAEZAWA, H
    SHIGEMASA, E
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 1351 - 1354
  • [3] X-ray Microscopy Beamlines at SSRF - Present Status and Future Plan
    Xu, H.
    Yu, X.
    Tai, R.
    [J]. 10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 52 - 56
  • [4] CHROMATICITY CORRECTION FOR THE VUV AND SOFT-X-RAY RING AT THE PHOTON FACTORY
    KOBAYASHI, Y
    KAMIYA, Y
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (02): : 1726 - 1730
  • [5] SOFT-X-RAY MICROSCOPY
    BAEZ, AV
    [J]. PHYSICS TODAY, 1986, 39 (05) : 11 - &
  • [6] SOFT-X-RAY MICROSCOPY
    KIRZ, J
    SAYRE, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 695 - 697
  • [7] SOFT-X-RAY MICROSCOPY IN BIOLOGY AND MEDICINE - STATUS AND PROSPECTS
    ROTHMAN, S
    ANDERSON, E
    ATTWOOD, D
    BATSON, P
    BUCKLEY, C
    GONCZ, K
    HOWELLS, M
    JACOBSEN, C
    KERN, D
    KIRZ, J
    RARBACK, H
    RIVERS, M
    SHU, D
    TACKABERRY, R
    TUREK, S
    [J]. PHYSICA SCRIPTA, 1990, T31 : 18 - 22
  • [8] X-ray microbeam irradiation systems at the photon factory - Present status and future plans
    Kobayashi, K.
    Usami, N.
    Maezawa, H.
    Hayashi, T.
    Hieda, K.
    Takakura, K.
    Furusawa, Y.
    [J]. RADIATION RESEARCH, 2006, 166 (04) : 661 - 661
  • [9] DEVELOPMENT OF A VUV SOFT-X-RAY MONOCHROMATOR FOR UNDULATOR RADIATION AT THE PHOTON FACTORY
    MURAMATSU, Y
    MAEZAWA, H
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2078 - 2080
  • [10] SOFT-X-RAY DOSIMETRY - CALIBRATING THE SOFT-X-RAY CONTACT MICROSCOPY STATION
    GUTTMANN, GD
    HENKE, B
    HOWELLS, MR
    KERNER, JA
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 455 - 455