PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)

被引:108
|
作者
HEIJMEN, BJM [1 ]
PASMA, KL [1 ]
KROONWIJK, M [1 ]
ALTHOF, VGM [1 ]
DEBOER, JCJ [1 ]
VISSER, AG [1 ]
HUIZENGA, H [1 ]
机构
[1] RISO,DEPT RADIOTHERAPY & CURIETHERAPY,7415 CM DEVENTER,NETHERLANDS
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1995年 / 40卷 / 11期
关键词
D O I
10.1088/0031-9155/40/11/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Physical characteristics of a commercially available electronic portal imaging device (EPID), relevant to dosimetric applications in high-energy photon beams, have been investigated. The EPID basically consists of a fluorescent screen, mirrors and a CCD camera. Image acquisition for portal dose measurement has been performed with a special procedure, written in the command language that comes with the system The observed day-to-day variation in local EPID responses, i.e. measured grey scale value (EPID signal) per unit of delivered portal dose, is 0.4% (1 SD); day-to-day variations in relative EPID responses (e.g. normalized to the on-axis response) are within 0.2% (1 SD). Measured grey scale values are linearly proportional to transmitted portal doses with a proportionality constant which is independent of the thickness of a flat, water-equivalent absorber in the beam, but which does significantly depend on the size of the applied x-ray beam. It is shown that the observed increase in EPID response with increasing field size is mainly due to contributions to the EPID signals from scattered light: visible photons produced by the x-ray beam in a point of the fluorescent screen not only generate a grey scale value in the corresponding point of the EPID image, but also lead (due to scatter from components of the EPID structure onto the CCD chip) to an increased grey scale value at all other points of the image. A point spread function, derived from measured data and describing the increase in EPID response at the beam axis due to off-axis irradiation of the fluorescent screen, has been successfully applied to connect portal doses with grey scale values measured with the EPID.
引用
收藏
页码:1943 / 1955
页数:13
相关论文
共 50 条
  • [41] Simple Proposal for Dosimetry with an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) Using Commercial Software Modules
    Liebich, Janett
    Licher, Joerg
    Scherf, Christian
    Kara, Eugen
    Koch, Nadine
    Roedel, Claus
    Ramm, Ulla
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (05) : 316 - 321
  • [42] EPIDEEP: Using a Deep Learning Model to Predict In Vivo Electronic Portal Imaging Device (EPID) Transit Images
    Anderson, B. M.
    Moore, L.
    Moore, K. L.
    Bojechko, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E645 - E645
  • [43] A new approach for the pixel map sensitivity (PMS) evaluation of an electronic portal imaging device (EPID)
    Boriano, Alberto
    Lucio, Francesco
    Calamia, Elisa
    Russi, Elvio
    Marchetto, Flavio
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (06): : 234 - 250
  • [44] Modeling Electronic Portal Imaging Device for Dose Reconstruction using Monte Carlo Method
    Jung, J. W.
    Kim, J. O.
    Yeo, I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S724 - S724
  • [45] Evaluation of a new Electronic Portal Imaging Device (EPID) for pre-treatment and in vivo dosimetry
    Reilly, A. J.
    Van Esch, A.
    Carver, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S182 - S183
  • [46] Measurements for quality assurance of an Electronic Portal Imaging Device (EPID) with the QC Phantom by the PTW company
    Liebich, J.
    Licher, J.
    Scherf, C.
    Kara, E.
    Koch, N.
    Roedel, C.
    Ramm, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 94 - 94
  • [47] Electronic Portal Imaging Device (EPID) Modeling in EGSnrc/DOSXYZnrc with Effective Atomic Number Scaling
    Yoon, J.
    Jung, H.
    Zheng, D.
    Yeo, I.
    MEDICAL PHYSICS, 2022, 49 (06) : E909 - E909
  • [48] Radiological thickness measurement using a liquid ionization chamber electronic portal imaging device
    Evans, PM
    Donovan, EM
    Partridge, M
    Bidmead, AM
    Garton, A
    Mubata, C
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (06): : N89 - N97
  • [49] Simple Proposal for Dosimetry with an Elekta iViewGTTM Electronic Portal Imaging Device (EPID) Using Commercial Software ModulesEinfacher Vorschlag für die Dosimetrie mit einem Elekta iViewGTTM Electronic Portal Imaging Device (EPID) mit kommerziellen Softwaremodulen
    Janett Liebich
    Jörg Licher
    Christian Scherf
    Eugen Kara
    Nadine Koch
    Claus Rödel
    Ulla Ramm
    Strahlentherapie und Onkologie, 2011, 187 (5)
  • [50] Clinical Feasibility of Using an Electronic Portal Imaging Device for Position Verification during Conventional Radiotherapy
    Shen, Yuxiaotong
    Zhang, Jie
    Ge, Yun
    Chen, Ying
    Li, Haiwei
    Sun, Wei
    Ji, Mingxi
    Wei, Quanbo
    Cai, Jing
    Li, Bing
    2016 IEEE 10TH INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE AND ENGINEERING (NANOMED), 2016, : 99 - 103