Simple Proposal for Dosimetry with an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) Using Commercial Software Modules

被引:1
|
作者
Liebich, Janett [1 ]
Licher, Joerg [1 ]
Scherf, Christian [1 ]
Kara, Eugen [1 ]
Koch, Nadine [1 ]
Roedel, Claus [1 ]
Ramm, Ulla [1 ]
机构
[1] Klinikum Johann Wolfgang Goethe Univ Frankfurt Ma, Zentrum Radiol, Klin Strahlentherapie & Onkol, Frankfurt, Germany
关键词
EPID dosimetry; Amorphous silicon EPID; IMRT verification; Dose response; INTENSITY-MODULATED RADIOTHERAPY; DOSE-RESPONSE; IMRT; FIELD; VERIFICATION; CALIBRATION; RADIATION; MATRIX; MODEL;
D O I
10.1007/s00066-011-2176-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: An electronic portal imaging device (EPID) is used to control for patient setup and positioning during fractionated radiotherapy. Due to the rising complexity and conformity of irradiation techniques, the demand for an accurate verification of the dose delivered to the patient has also increased. The purpose of this study was to investigate a simple guidance for dosimetry with an Elekta iViewGT (TM) EPID using commercial software modules. Material and Methods: EPID measurements were performed using an Elekta iViewGT (TM) EPID on a linear accelerator with 6 MV x-ray beam. The EPID signal was studied for reproducibility, as well as characteristics as a function of dose, dose rate, and field size. A series of experiments, comparing the response of the flat panel imager and ionization chamber measurements of dose, determine the parameters for the calibration model. EPID measurements were also compared with calculations of the treatment planning system. Results: We found a stable response of the EPID signal over a period of 14 months. It showed nonlinearity depending on dose up to 6.8%. There were low oscillations up to 1.2% depending on dose rate. For all fields, the calibrated flat panel profiles match the measured and calculated dose profiles with maximum deviation of 2-3% for the in-field region. In the high gradient areas, higher differences up to 6% were found. Conclusions: The gamma evaluation indicates good correlation between predicted and acquired EPID images. The EPID-based pretreatment IMRT verification method will help to improve the quality assurance procedure.
引用
收藏
页码:316 / 321
页数:6
相关论文
共 50 条
  • [1] Simple Suggestion for Dosimetry of an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) with commercial Software modules
    Liebich, J.
    Licher, J.
    Scherf, C.
    Koch, N.
    Kara, E.
    Roedel, C.
    Ramm, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 107 - 107
  • [2] SIMPLE PROPOSAL FOR DOSIMETRY WITH AN ELEKTA IVIEWGTTM ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    Liebich, J.
    Licher, J.
    Scherf, C.
    Kara, E.
    Koch, N.
    Roedel, C.
    Ramm, U.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S419 - S419
  • [3] Simple Proposal for Dosimetry with an Elekta iViewGTTM Electronic Portal Imaging Device (EPID) Using Commercial Software ModulesEinfacher Vorschlag für die Dosimetrie mit einem Elekta iViewGTTM Electronic Portal Imaging Device (EPID) mit kommerziellen Softwaremodulen
    Janett Liebich
    Jörg Licher
    Christian Scherf
    Eugen Kara
    Nadine Koch
    Claus Rödel
    Ulla Ramm
    Strahlentherapie und Onkologie, 2011, 187 (5)
  • [4] Transit Dosimetry for Verification of Dose Delivery Using Electronic Portal Imaging Device (EPID)
    Baek, T.
    Chung, E.
    Lee, S.
    Yoon, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 301 - 301
  • [5] TREATMENT QUALITY ASSESSMENT USING IN VIVO ELECTRONIC PORTAL IMAGING DEVICE (EPID) DOSIMETRY IN RADIOTHERAPY
    Fuangrod, Todsaporn
    Simpson, John
    Greer, Peter
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2016, 12 : 13 - 14
  • [6] In vivo Dosimetry in extracranial stereotactic Radiotherapy using EPID ("electronic imaging and portal dosimetry")
    Moustakis, C.
    Ernst, I
    Buether, F.
    Eschrich, Y.
    Czekalla, B.
    Schaefer, K. P.
    Haverkamp, U.
    Eich, H. T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 55 - 56
  • [7] Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    Pasma, KL
    Kroonwijk, M
    Quint, S
    Visser, AG
    Heijmen, BJM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05): : 1297 - 1303
  • [8] Dosimetry Study On An Amorphous Silicon Electronic Portal Imaging Device(a-Si EPID)
    Wu, Q.
    Hu, Y.
    MEDICAL PHYSICS, 2009, 36 (06) : 2596 - +
  • [9] PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    HEIJMEN, BJM
    PASMA, KL
    KROONWIJK, M
    ALTHOF, VGM
    DEBOER, JCJ
    VISSER, AG
    HUIZENGA, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1943 - 1955
  • [10] Radiotherapy delivery error detection with electronic portal imaging device (EPID)-based in vivo dosimetry
    Yang Xueying
    Geng Lisheng
    Huang David
    Li Kaiwen
    Zhuang Hongqing
    Cai Jing
    Yang Ruijie
    中华医学杂志(英文版), 2023, 136 (08)