Simple Proposal for Dosimetry with an Elekta iViewGT™ Electronic Portal Imaging Device (EPID) Using Commercial Software Modules

被引:1
|
作者
Liebich, Janett [1 ]
Licher, Joerg [1 ]
Scherf, Christian [1 ]
Kara, Eugen [1 ]
Koch, Nadine [1 ]
Roedel, Claus [1 ]
Ramm, Ulla [1 ]
机构
[1] Klinikum Johann Wolfgang Goethe Univ Frankfurt Ma, Zentrum Radiol, Klin Strahlentherapie & Onkol, Frankfurt, Germany
关键词
EPID dosimetry; Amorphous silicon EPID; IMRT verification; Dose response; INTENSITY-MODULATED RADIOTHERAPY; DOSE-RESPONSE; IMRT; FIELD; VERIFICATION; CALIBRATION; RADIATION; MATRIX; MODEL;
D O I
10.1007/s00066-011-2176-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: An electronic portal imaging device (EPID) is used to control for patient setup and positioning during fractionated radiotherapy. Due to the rising complexity and conformity of irradiation techniques, the demand for an accurate verification of the dose delivered to the patient has also increased. The purpose of this study was to investigate a simple guidance for dosimetry with an Elekta iViewGT (TM) EPID using commercial software modules. Material and Methods: EPID measurements were performed using an Elekta iViewGT (TM) EPID on a linear accelerator with 6 MV x-ray beam. The EPID signal was studied for reproducibility, as well as characteristics as a function of dose, dose rate, and field size. A series of experiments, comparing the response of the flat panel imager and ionization chamber measurements of dose, determine the parameters for the calibration model. EPID measurements were also compared with calculations of the treatment planning system. Results: We found a stable response of the EPID signal over a period of 14 months. It showed nonlinearity depending on dose up to 6.8%. There were low oscillations up to 1.2% depending on dose rate. For all fields, the calibrated flat panel profiles match the measured and calculated dose profiles with maximum deviation of 2-3% for the in-field region. In the high gradient areas, higher differences up to 6% were found. Conclusions: The gamma evaluation indicates good correlation between predicted and acquired EPID images. The EPID-based pretreatment IMRT verification method will help to improve the quality assurance procedure.
引用
收藏
页码:316 / 321
页数:6
相关论文
共 50 条
  • [31] A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)
    Herchko, S.
    Ding, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3575 - 3575
  • [32] Commissioning and Evaluation of an Electronic Portal Imaging Device-Based In-Vivo Dosimetry Software
    Held, Mareike
    Cheung, Joey
    Andujar, Angelica Perez
    Husson, Francois
    Morin, Olivier
    CUREUS, 2018, 10 (02):
  • [33] QUALITY ASSURANCE OF ENHANCED DYNAMIC WEDGE (EDW) USING ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    Narayanan, S.
    Arasu, K.
    Narayanan, G.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S235 - S235
  • [34] Concept for On Line - Verification of IMRT - Radiation treatment using electronic portal imaging device (EPID).
    Muehle, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 18 - 18
  • [35] Verification of multi-leaf collimator position accuracy using a commercial EPID and vendor supplied portal dosimetry software
    Taylor, M.
    Lambert, M.
    Harris, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2505 - 2505
  • [36] A Clinical Objective IMRT QA Method Based on Portal Dosimetry and Electronic Portal Imager Device (EPID) Measurement
    Zhang, Miao
    Qin, Songbing
    Chen, Ting
    Kim, Sung
    Jabbour, Salma
    Haffty, Bruce
    Yue, Ning J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (02) : 145 - 150
  • [37] Physical characteristics of a commercial electronic portal imaging device
    Althof, VGM
    deBoer, JCJ
    Huizenga, H
    Stroom, JC
    Visser, AG
    Swanenburg, BN
    MEDICAL PHYSICS, 1996, 23 (11) : 1845 - 1855
  • [38] The effect of respiratory motion on electronic portal imaging device dosimetry
    Fielding, Andrew L.
    Mendieta, Jessica Benitez
    Maxwell, Sarah
    Jones, Catherine
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (03): : 45 - 55
  • [39] The fast calibration model for dosimetry with an electronic portal imaging device
    Schade, Stephanie
    Engenhart-Cabillic, Rita
    Zink, Klemens
    Czarnecki, Damian
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (11):
  • [40] OPTIMIZATION AND EVALUATION OF THE PORTAL DOSIMETRY PROFILE CORRECTION FOR AN ELECTRONIC PORTAL IMAGING DEVICE
    Samsoe, E.
    Sjostrom, D.
    Karlsson, A.
    Behrens, C.
    Van Esch, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S215 - S215