PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)

被引:108
|
作者
HEIJMEN, BJM [1 ]
PASMA, KL [1 ]
KROONWIJK, M [1 ]
ALTHOF, VGM [1 ]
DEBOER, JCJ [1 ]
VISSER, AG [1 ]
HUIZENGA, H [1 ]
机构
[1] RISO,DEPT RADIOTHERAPY & CURIETHERAPY,7415 CM DEVENTER,NETHERLANDS
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1995年 / 40卷 / 11期
关键词
D O I
10.1088/0031-9155/40/11/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Physical characteristics of a commercially available electronic portal imaging device (EPID), relevant to dosimetric applications in high-energy photon beams, have been investigated. The EPID basically consists of a fluorescent screen, mirrors and a CCD camera. Image acquisition for portal dose measurement has been performed with a special procedure, written in the command language that comes with the system The observed day-to-day variation in local EPID responses, i.e. measured grey scale value (EPID signal) per unit of delivered portal dose, is 0.4% (1 SD); day-to-day variations in relative EPID responses (e.g. normalized to the on-axis response) are within 0.2% (1 SD). Measured grey scale values are linearly proportional to transmitted portal doses with a proportionality constant which is independent of the thickness of a flat, water-equivalent absorber in the beam, but which does significantly depend on the size of the applied x-ray beam. It is shown that the observed increase in EPID response with increasing field size is mainly due to contributions to the EPID signals from scattered light: visible photons produced by the x-ray beam in a point of the fluorescent screen not only generate a grey scale value in the corresponding point of the EPID image, but also lead (due to scatter from components of the EPID structure onto the CCD chip) to an increased grey scale value at all other points of the image. A point spread function, derived from measured data and describing the increase in EPID response at the beam axis due to off-axis irradiation of the fluorescent screen, has been successfully applied to connect portal doses with grey scale values measured with the EPID.
引用
收藏
页码:1943 / 1955
页数:13
相关论文
共 50 条
  • [31] Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients
    Pasma, KL
    Kroonwijk, M
    Quint, S
    Visser, AG
    Heijmen, BJM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05): : 1297 - 1303
  • [32] Towards a Next-Generation Electronic Portal Device for Simultaneous Imaging and Dose Verification in Radiotherapy
    Blake, S.
    Vial, P.
    Holloway, L.
    Kuncic, Z.
    MEDICAL PHYSICS, 2014, 41 (06) : 511 - 511
  • [33] Assement of the accuracy of treatment fields with electronic portal imaging device (EPID) in a breast irradiation
    Cetinayak, H. O.
    Gorken, I.
    Eyiler, F.
    Dag, N.
    Bayraktar, F.
    Sengunay, F.
    Yigitbasi, L.
    Ates, L.
    Alanyali, H.
    Kinay, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S278 - S279
  • [34] Modeling the temporal-spatial nature of the readout of an electronic portal imaging device (EPID)
    Abbasian, Parandoush
    McCowan, Peter M.
    Rickey, Daniel W.
    Van Uytven, Eric
    McCurdy, Boyd M. C.
    MEDICAL PHYSICS, 2020, 47 (10) : 5301 - 5311
  • [35] Dosimetry Study On An Amorphous Silicon Electronic Portal Imaging Device(a-Si EPID)
    Wu, Q.
    Hu, Y.
    MEDICAL PHYSICS, 2009, 36 (06) : 2596 - +
  • [36] The linear accelerator mechanical and radiation isocentre assessment with an electronic portal imaging device (EPID)
    Liu G.
    van Doorn T.
    Bezak E.
    Australasian Physics & Engineering Sciences in Medicine, 2004, 27 (3): : 111 - 117
  • [37] Verification of electron fields by means of EPID-method (electronic portal imaging device)
    Poser, A.
    Gaupp, S.
    Buchgeister, M.
    Paulsen, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 108 - 109
  • [38] The use of an electronic portal imaging system to measure portal dose and portal dose profiles
    Parsaei, H
    El-Khatib, E
    Rajapakshe, R
    MEDICAL PHYSICS, 1998, 25 (10) : 1903 - 1909
  • [39] Movement of an Elekta Electronic Portal Imaging Device (EPID) during Gantry Rotation: Quantification and Correction for the Verification of Dose Distributions
    Koehn, J.
    Licher, J.
    Mielke, M.
    Loutfi-Krauss, B.
    Bluemer, N.
    Roedel, C.
    Scherf, C.
    Ramm, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S36 - S36
  • [40] Robust and Efficient Process for Acceptance Testing of Varian TrueBeam Linacs Using An Electronic Portal Imaging Device (EPID)
    Yaddanapudi, S.
    Cai, B.
    Harry, T.
    Sun, B.
    Li, H.
    Noel, C.
    Goddu, S.
    Pawlicki, T.
    Mutic, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3190 - 3190