PORTAL DOSE MEASUREMENT IN RADIOTHERAPY USING AN ELECTRONIC PORTAL IMAGING DEVICE (EPID)

被引:108
|
作者
HEIJMEN, BJM [1 ]
PASMA, KL [1 ]
KROONWIJK, M [1 ]
ALTHOF, VGM [1 ]
DEBOER, JCJ [1 ]
VISSER, AG [1 ]
HUIZENGA, H [1 ]
机构
[1] RISO,DEPT RADIOTHERAPY & CURIETHERAPY,7415 CM DEVENTER,NETHERLANDS
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1995年 / 40卷 / 11期
关键词
D O I
10.1088/0031-9155/40/11/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Physical characteristics of a commercially available electronic portal imaging device (EPID), relevant to dosimetric applications in high-energy photon beams, have been investigated. The EPID basically consists of a fluorescent screen, mirrors and a CCD camera. Image acquisition for portal dose measurement has been performed with a special procedure, written in the command language that comes with the system The observed day-to-day variation in local EPID responses, i.e. measured grey scale value (EPID signal) per unit of delivered portal dose, is 0.4% (1 SD); day-to-day variations in relative EPID responses (e.g. normalized to the on-axis response) are within 0.2% (1 SD). Measured grey scale values are linearly proportional to transmitted portal doses with a proportionality constant which is independent of the thickness of a flat, water-equivalent absorber in the beam, but which does significantly depend on the size of the applied x-ray beam. It is shown that the observed increase in EPID response with increasing field size is mainly due to contributions to the EPID signals from scattered light: visible photons produced by the x-ray beam in a point of the fluorescent screen not only generate a grey scale value in the corresponding point of the EPID image, but also lead (due to scatter from components of the EPID structure onto the CCD chip) to an increased grey scale value at all other points of the image. A point spread function, derived from measured data and describing the increase in EPID response at the beam axis due to off-axis irradiation of the fluorescent screen, has been successfully applied to connect portal doses with grey scale values measured with the EPID.
引用
收藏
页码:1943 / 1955
页数:13
相关论文
共 50 条
  • [21] SIMPLE PROPOSAL FOR DOSIMETRY WITH AN ELEKTA IVIEWGTTM ELECTRONIC PORTAL IMAGING DEVICE (EPID)
    Liebich, J.
    Licher, J.
    Scherf, C.
    Kara, E.
    Koch, N.
    Roedel, C.
    Ramm, U.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S419 - S419
  • [22] A Novel Method for Fast Image Simulation of Electronic Portal Imaging Device (EPID)
    Shi, M.
    Myronakis, M.
    Hu, Y.
    Berbeco, R.
    MEDICAL PHYSICS, 2018, 45 (06) : E478 - E478
  • [23] Electronic portal imaging device (EPID) based on a novel camera with avalanche multiplication
    Pang, G
    Zhao, W
    Luhta, R
    Rowlands, JA
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 195 - 201
  • [24] Evaluation of the mechanical alignment of a linear accelerator with an electronic portal imaging device (EPID)
    Liu, G.
    Van Doorn, T.
    Bezak, E.
    Australasian Physical and Engineering Sciences in Medicine, 2000, 23 (03): : 74 - 80
  • [25] Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device
    McCurdy, BMC
    Luchka, K
    Pistorius, S
    MEDICAL PHYSICS, 2001, 28 (06) : 911 - 924
  • [26] A Clinical Objective IMRT QA Method Based on Portal Dosimetry and Electronic Portal Imager Device (EPID) Measurement
    Zhang, Miao
    Qin, Songbing
    Chen, Ting
    Kim, Sung
    Jabbour, Salma
    Haffty, Bruce
    Yue, Ning J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (02) : 145 - 150
  • [27] Portal dose measurements with a video-based electronic portal imaging device using a deconvolution algorithm
    Pasma, KL
    Kroonwijk, M
    Visser, AG
    Heijmen, BJM
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 282 - 284
  • [28] Improvement of radiotherapy treatment delivery accuracy using an electronic portal imaging device
    Dirkx, M. L. P.
    de Boer, J. C. J.
    Heijmen, B. J. M.
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 70 - 79
  • [29] Geometrical Verification of Real-Time Tumor Tracking Using Electronic Portal Imaging Device (EPID)
    Han-Oh, Y.
    Yi, B.
    Berman, B.
    Yu, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [30] Three-dimensional dose reconstruction using an electronic portal imaging device
    Hagness, C
    Herman, M
    MEDICAL PHYSICS, 2003, 30 (06) : 1345 - 1345