Targeting accuracy at couch kick for a frameless image guided radiosurgery system

被引:1
|
作者
Huang, Yimei [1 ]
Zhao, Bo [1 ]
Kim, Joshua [1 ]
Wen, Ning [1 ]
Chetty, Indrin J. [1 ]
Siddiqui, Salim [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Radiat Oncol, 2799 W Grand Blvd, Detroit, MI 48202 USA
来源
JOURNAL OF RADIOSURGERY AND SBRT | 2018年 / 5卷 / 02期
关键词
frameless radiosurgery; trigeminal neuralgia; image-guided radiosurgery;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose/Objectives: Targeting accuracy at all possible couch angles needs to be carefully evaluated prior to initiating a frameless image-guided stereotactic radiosurgery program on a Linac for treating functional disorders such as trigeminal neuralgia. In this study, we report positioning accuracy with stereoscopic x-ray imaging over the complete range of couch rotation using anthropomorphic head phantoms. Materials/Methods: An anthropomorphic head phantom with three 5 mm tungsten BBs as hidden targets was CT simulated. A group of 7 arcs was planned with couch angles from 0 to 90 degrees in 15 degrees increments. A pair of stereoscopic x-ray images that auto-matches to planning CT according to bony anatomy was utilized to position each BB to machine isocenter at all planned couch angles. Targeting accuracy was measured by stereoscopic x-ray imaging of the BB itself, which provides the distance from the centroid of BB to the x-ray imaging isocenter. For each BB, the hidden target test was repeated 5 times at couch 0 degrees and 3 times at other couch angles, resulting in a total of 69 measurements, each with random initial setup deviation. Following the same workflow, a second anthropomorphic head phantom with two 5 mm BBs was utilized to evaluate localization accuracy at couch angles of 0 through 270 degrees in 15 degrees increments, resulting in another 18 measurements. Results: Residual setup deviation following image guidance in the first head phantom was 0.6 +/- 0.1, 0.4 +/- 0.1, and 0.4 +/- 0.1 mm, respectively, at the three BBs, and 0.5 +/- 0.1 mm overall (N=69). Comparable results of 0.4 +/- 0.1 mm (N=18) were achieved with the second head phantom. Combining results from both phantoms, the targeting accuracy was 0.5 +/- 0.1 mm (range 0.2-0.8 mm). No apparent correlation was observed between targeting accuracy and couch rotation. Conclusions: Accurate positioning within 1 mm can be achieved with stereoscopic x-ray imaging at any couch angle. Frameless image-guided stereotactic radiosurgery could achieve targeting accuracy similar to that of frame-based systems for high dose treatment of trigeminal neuralgia.
引用
收藏
页码:123 / 129
页数:7
相关论文
共 50 条
  • [31] The accuracy of frameless stereotactic intracranial radiosurgery
    Verbakel, Wilko F. A. R.
    Lagerwaard, Frank J.
    Verduin, Arjan J. E.
    Heukelom, Stan
    Slotman, Ben J.
    Cuijpers, Johan P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 97 (03) : 390 - 394
  • [32] Margin of Error for a Frameless Image Guided Radiosurgery System: Direct Confirmation Based on Posttreatment MRI Scans
    Luo, G.
    Neimat, J. S.
    Cmelak, A. J.
    Kirschner, A. N.
    Attia, A.
    Morales-Paliza, M.
    Ding, G. X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S84 - S84
  • [33] Margin of error for a frameless image guided radiosurgery system: Direct confirmation based on posttreatment MRI scans
    Luo, Guozhen
    Neimat, Joseph S.
    Cmelak, Anthony
    Kirschner, Austin N.
    Attia, Albert
    Morales-Paliza, Manuel
    Ding, George X.
    PRACTICAL RADIATION ONCOLOGY, 2017, 7 (03) : E223 - E231
  • [34] ABANDONING INVASIVE HEAD FRAMES IN STEREOTACTIC RADIOSURGERY IN FAVOR OF AN IMAGE GUIDED FRAMELESS MASK PROCEDURE? VALIDATION OF POSITIONING ACCURACY
    van der Borden, A. J.
    Bolt, R.
    Blokzijl, E.
    Bijl, H. P.
    Langendijk, J.
    van 't Veld, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S523 - S523
  • [35] Frameless stereotactic radiosurgery for brain metastases using image guided radiotherapy (IGRT)
    Lopez, E.
    Lazo, A.
    Arregui, G.
    Serradilla, A.
    Rivas, D.
    Sacchetti, A.
    Nunez, M. I.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S258 - S258
  • [36] INITIAL EXPERIENCE WITH USING FRAMELESS IMAGE - GUIDED RADIOSURGERY FOR THE TREATMENT OF BRAIN METASTASES
    Auslands, K.
    Liepa, Z.
    Apskalne, D.
    Ozols, R.
    NEURO-ONCOLOGY, 2012, 14 : 76 - 77
  • [37] Novalis frameless image-guided noninvasive radiosurgery: Initial experience - Comments
    Phillips, Mark
    Goodkin, Robert
    Schlesinger, David
    Sheehan, Jason P.
    Chen, Joseph C. T.
    Kondziolka, Douglas
    NEUROSURGERY, 2008, 62 (05) : A17 - A18
  • [38] Frameless Image-Guided Radiosurgery for Initial Treatment of Typical Trigeminal Neuralgia
    Chen, Joseph C. T.
    Rahimian, Javad
    Rahimian, Rombod
    Arellano, Alonso
    Miller, Michael J.
    Girvigian, Michael R.
    WORLD NEUROSURGERY, 2010, 74 (4-5) : 538 - 543
  • [39] Localization Technique for Frameless Image-guided Robotic Radiosurgery of Arteriovenous Malformations
    Hristov, D. H.
    Liu, L.
    Moore, T.
    Dodd, R.
    Marks, M.
    Gibbs, I. C.
    Adler, J.
    Chang, S.
    Do, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S679 - S680
  • [40] Factors influencing set up margins for image guided frameless stereotactic radiosurgery
    Talukdar, R.
    Dasgupta, A.
    Chatterjee, A.
    Mishra, A.
    Chowdhury, O. Roy
    Joshi, K. J.
    Sutar, A.
    Goda, J. Sastri
    Krishnamurthy, R.
    Wadasadawala, T.
    Pathak, R.
    Maitre, P.
    Murthy, V.
    Gupta, A.
    Mittal, P.
    Chopra, S.
    Tibdewal, A.
    Mummudi, N.
    Singh, V.
    Shetty, P.
    Moiyadi, A.
    Kinhikar, R.
    Sarin, R.
    Agarwal, J.
    Gupta, T.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S919 - S920