Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis

被引:0
|
作者
Hisashi Nakano
Satoshi Tanabe
Takumi Yamada
Satoru Utsunomiya
Takeshi Takizawa
Madoka Sakai
Ryuta Sasamoto
Hironori Sakai
Toshimichi Nakano
Hirotake Saito
Atsushi Ohta
Motoki Kaidu
Hiroyuki Ishikawa
机构
[1] Niigata University Medical and Dental Hospital,Department of Radiation Oncology
[2] Niigata University Medical and Dental Hospital,Section of Radiology, Department of Clinical Support
[3] Niigata University Graduate School of Health Sciences,Department of Radiological Technology
[4] Niigata Neurosurgical Hospital,Department of Radiation Oncology
[5] Niigata University Graduate School of Medical and Dental Sciences,Department of Radiology and Radiation Oncology
来源
Radiological Physics and Technology | 2021年 / 14卷
关键词
Volumetric modulated arc therapy; VMAT; Single-isocenter technique; PTV margin; Rotational error; Setup error;
D O I
暂无
中图分类号
学科分类号
摘要
Through geometrical simulation, we evaluated the effect of rotational error in patient setup on geometrical coverage and calculated the maximum distance between the isocenter and target, where the clinical PTV margin secures geometrical coverage with a single-isocenter technique. We used simulated spherical GTVs with diameters of 1.0 (GTV 1), 1.5 (GTV 2), 2.0 (GTV 3), and 3.0 cm (GTV 4). The location of the target center was set such that the distance between the target and isocenter ranged from 0 to 15 cm. We created geometrical coverage vectors so that each target was entirely covered by 100% of the prescribed dose. The vectors of the target positions were simultaneously rotated within a range of 0°–2.0° around the x-, y-, and z-axes. For each rotational error, the reduction in geometrical coverage of the targets was calculated and compared with that obtained for a rotational error of 0°. The tolerance value of the geometrical coverage reduction was defined as 5% of the GTV. The maximum distance that satisfied the 5% tolerance value for different values of rotational error at a clinical PTV margin of 0.1 cm was calculated. When the rotational errors were 0.5° for a 0.1 cm PTV margin, the maximum distances were as follows: GTV 1: 7.6 cm; GTV 2: 10.9 cm; GTV 3: 14.3 cm; and GTV 4: 21.4 cm. It might be advisable to exclude targets that are > 7.6 cm away from the isocenter with a single-isocenter technique to satisfy the tolerance value for all GTVs.
引用
收藏
页码:57 / 63
页数:6
相关论文
共 50 条
  • [31] Investigation of Plan Quality Metrics for Multiple-Metastases Using Single-Isocenter Radiosurgery Technique with Millennium MLC
    Flores-Martinez, E.
    Kim, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E804 - E804
  • [32] Dynamic conformal arcs-based single-isocenter VMAT planning technique for radiosurgery of multiple brain metastases
    Pokhrel, Damodar
    Palmiero, Allison N.
    Bernard, Mark E.
    St Clair, William
    MEDICAL DOSIMETRY, 2021, 46 (02) : 195 - 200
  • [33] Single-Isocenter Linac-Based Radiosurgery for Brain Metastases with Coplanar Arcs: A Dosimetric and Clinical Analysis
    Faccenda, Valeria
    Panizza, Denis
    Pisoni, Valerio
    Trivellato, Sara
    Daniotti, Martina Camilla
    Bianchi, Sofia Paola
    De Ponti, Elena
    Arcangeli, Stefano
    CANCERS, 2023, 15 (18)
  • [34] Using a fixed-jaw technique to achieve superior delivery accuracy and plan quality in single-isocenter multiple-target stereotactic radiosurgery for brain metastases
    Lai, Jialu
    Liu, Shoupeng
    Liu, Jia
    Jia, Yuming
    Lei, Kaijian
    Li, An
    Deng, Zhonghua
    Li, Bin
    Wang, Haitao
    Zhou, Lin
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (02) : 76 - 83
  • [35] Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery
    Huang, C.
    Ren, L.
    Kirkpatrick, J.
    Wang, Z.
    MEDICAL PHYSICS, 2012, 39 (06) : 3854 - 3854
  • [36] Stereotactic Radiosurgery od multiple brain mets using an novel single-isocenter approach: An evaluation and comparison with standard SRS, VMAT and Gammaknife
    Todorovic, M.
    Kretschmar, M.
    Matnjani, G.
    Petersen, C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S37 - S37
  • [37] Simultaneous stereotactic radiosurgery of multiple brain metastases using single-isocenter dynamic conformal arc therapy: a prospective monocentric registry trial
    Raphael Bodensohn
    Anna-Lena Kaempfel
    Daniel Felix Fleischmann
    Indrawati Hadi
    Jan Hofmaier
    Sylvia Garny
    Michael Reiner
    Robert Forbrig
    Stefanie Corradini
    Niklas Thon
    Claus Belka
    Maximilian Niyazi
    Strahlentherapie und Onkologie, 2021, 197 : 601 - 613
  • [38] Retrospective quality metrics review of stereotactic radiosurgery plans treating multiple targets using single-isocenter volumetric modulated arc therapy
    Cui, Yunfeng
    Gao, Hao
    Zhang, Jiahan
    Kirkpatrick, John P.
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (06): : 93 - 99
  • [39] Simultaneous stereotactic radiosurgery of multiple brain metastases using single-isocenter dynamic conformal arc therapy: a prospective monocentric registry trial
    Bodensohn, Raphael
    Kaempfel, Anna-Lena
    Fleischmann, Daniel Felix
    Hadi, Indrawati
    Hofmaier, Jan
    Garny, Sylvia
    Reiner, Michael
    Forbrig, Robert
    Corradini, Stefanie
    Thon, Niklas
    Belka, Claus
    Niyazi, Maximilian
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (07) : 601 - 613
  • [40] Variation in Normal Brain Sparing in Stereotactic Radiosurgery Plans Treating Multiple Targets Using Single-Isocenter Volumetric Modulated Arc Therapy
    Cui, Y.
    Gao, H.
    Kirkpatrick, J.
    Yin, F.
    MEDICAL PHYSICS, 2018, 45 (06) : E191 - E191