Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis

被引:0
|
作者
Hisashi Nakano
Satoshi Tanabe
Takumi Yamada
Satoru Utsunomiya
Takeshi Takizawa
Madoka Sakai
Ryuta Sasamoto
Hironori Sakai
Toshimichi Nakano
Hirotake Saito
Atsushi Ohta
Motoki Kaidu
Hiroyuki Ishikawa
机构
[1] Niigata University Medical and Dental Hospital,Department of Radiation Oncology
[2] Niigata University Medical and Dental Hospital,Section of Radiology, Department of Clinical Support
[3] Niigata University Graduate School of Health Sciences,Department of Radiological Technology
[4] Niigata Neurosurgical Hospital,Department of Radiation Oncology
[5] Niigata University Graduate School of Medical and Dental Sciences,Department of Radiology and Radiation Oncology
来源
Radiological Physics and Technology | 2021年 / 14卷
关键词
Volumetric modulated arc therapy; VMAT; Single-isocenter technique; PTV margin; Rotational error; Setup error;
D O I
暂无
中图分类号
学科分类号
摘要
Through geometrical simulation, we evaluated the effect of rotational error in patient setup on geometrical coverage and calculated the maximum distance between the isocenter and target, where the clinical PTV margin secures geometrical coverage with a single-isocenter technique. We used simulated spherical GTVs with diameters of 1.0 (GTV 1), 1.5 (GTV 2), 2.0 (GTV 3), and 3.0 cm (GTV 4). The location of the target center was set such that the distance between the target and isocenter ranged from 0 to 15 cm. We created geometrical coverage vectors so that each target was entirely covered by 100% of the prescribed dose. The vectors of the target positions were simultaneously rotated within a range of 0°–2.0° around the x-, y-, and z-axes. For each rotational error, the reduction in geometrical coverage of the targets was calculated and compared with that obtained for a rotational error of 0°. The tolerance value of the geometrical coverage reduction was defined as 5% of the GTV. The maximum distance that satisfied the 5% tolerance value for different values of rotational error at a clinical PTV margin of 0.1 cm was calculated. When the rotational errors were 0.5° for a 0.1 cm PTV margin, the maximum distances were as follows: GTV 1: 7.6 cm; GTV 2: 10.9 cm; GTV 3: 14.3 cm; and GTV 4: 21.4 cm. It might be advisable to exclude targets that are > 7.6 cm away from the isocenter with a single-isocenter technique to satisfy the tolerance value for all GTVs.
引用
收藏
页码:57 / 63
页数:6
相关论文
共 50 条
  • [41] Evaluation of Off-Axis Spatial Accuracy Using An Integrated Quality Assurance Phantom for Frameless Single-Isocenter Multitarget Stereotactic Radiosurgery
    Capaldi, D.
    Skinner, L.
    Dubrowski, P.
    Yu, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E412 - E412
  • [42] Multicomponent mathematical model for tumor volume calculation with setup error using single-isocenter stereotactic radiotherapy for multiple brain metastases
    Nakano, Hisashi
    Shiinoki, Takehiro
    Tanabe, Satoshi
    Nakano, Toshimichi
    Takizawa, Takeshi
    Utsunomiya, Satoru
    Sakai, Madoka
    Tanabe, Shunpei
    Ohta, Atsushi
    Kaidu, Motoki
    Nishio, Teiji
    Ishikawa, Hiroyuki
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 945 - 953
  • [43] Multicomponent mathematical model for tumor volume calculation with setup error using single-isocenter stereotactic radiotherapy for multiple brain metastases
    Hisashi Nakano
    Takehiro Shiinoki
    Satoshi Tanabe
    Toshimichi Nakano
    Takeshi Takizawa
    Satoru Utsunomiya
    Madoka Sakai
    Shunpei Tanabe
    Atsushi Ohta
    Motoki Kaidu
    Teiji Nishio
    Hiroyuki Ishikawa
    Physical and Engineering Sciences in Medicine, 2023, 46 : 945 - 953
  • [44] Clinical Evaluation of a Rotational Set-up Correction Device for Multiple Brain Metastases Using Single-Isocenter Stereotactic Radiation Therapy
    Usui, K.
    Isobe, A.
    Hara, N.
    Kawamoto, T.
    Oshima, M.
    Shikama, N.
    Sasai, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E775 - E775
  • [45] Cost-effectiveness of Linac-based single-isocenter non-coplanar technique (HyperArcTM) for brain metastases radiosurgery
    Filippo Alongi
    Alba Fiorentino
    Ruggero Ruggieri
    Francesco Ricchetti
    Patrick Kupelian
    Clinical & Experimental Metastasis, 2018, 35 : 601 - 603
  • [46] Cost-effectiveness of Linac-based single-isocenter non-coplanar technique (HyperArcTM) for brain metastases radiosurgery
    Alongi, Filippo
    Fiorentino, Alba
    Ruggieri, Ruggero
    Ricchetti, Francesco
    Kupelian, Patrick
    CLINICAL & EXPERIMENTAL METASTASIS, 2018, 35 (07) : 601 - 603
  • [47] Evaluation of additional treatment margins for compensating rotational random errors in linac-based single-isocenter stereotactic radiotherapy for multiple brain metastases
    Yoshida, Yasuhisa
    Soyama, Maki
    Azumi, Rieko
    JOURNAL OF RADIOSURGERY AND SBRT, 2022, 8 (01): : 59 - 62
  • [48] Patient-specific dose quality assurance of single-isocenter multiple brain metastasis stereotactic radiosurgery using PTW Octavius 4D
    McCulloch, James
    Pawlowski, Jamie
    Kirby, Neil
    Rasmussen, Karl
    Shi, Zheng
    Myers, Pamela
    Stathakis, Sotirios
    Papanikolaou, Niko
    Saenz, Daniel L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 107 - 115
  • [49] Treatment plan technique and quality for single-isocenter stereotactic ablative radiotherapy of multiple lung lesions with volumetric-modulated arc therapy or intensity-modulated radiosurgery
    Quan, Kimmen
    Xu, Karen M.
    Lalonde, Ron
    Horne, Zachary D.
    Bernard, Marke E.
    McCoy, Chuck
    Clump, David A.
    Burton, Steven A.
    Heron, Dwight E.
    FRONTIERS IN ONCOLOGY, 2015, 5
  • [50] A High Resolution Pre-Treatment VMAT QA Technique Based On EPID for Single Isocenter Multiple Mets Stereotactic Radiosurgery
    Wu, Q.
    Adamson, J.
    Liang, B.
    Liu, B.
    Zhou, F.
    MEDICAL PHYSICS, 2016, 43 (06) : 3685 - 3685