Retrospective quality metrics review of stereotactic radiosurgery plans treating multiple targets using single-isocenter volumetric modulated arc therapy

被引:4
|
作者
Cui, Yunfeng [1 ]
Gao, Hao [2 ]
Zhang, Jiahan [1 ]
Kirkpatrick, John P. [1 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Dept Radiat Oncol, Durham, NC 27708 USA
[2] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
来源
关键词
normal brain V12Gy; plan quality; single-isocenter multi-target VMAT; BRAIN METASTASES; LINEAR-ACCELERATOR; RADIOTHERAPY; BREAST; LUNG;
D O I
10.1002/acm2.12869
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To characterize key plan quality metrics in multi-target stereotactic radiosurgery (SRS) plans treated using single-isocenter volumetric modulated arc therapy (VMAT) in comparison to dynamic conformal arc (DCA) plans treating single target. To investigate the feasibility of quality improvement in VMAT planning based on previous planning knowledge. Materials and methods 97 VMAT plans of multi-target and 156 DCA plans of single-target treated in 2017 at a single institution were reviewed. A total of 605 targets were treated with these SRS plans. The prescription dose was normalized to 20 Gy in all plans for this analysis. Two plan quality metrics, target conformity index (CI) and normal tissue volume receiving more than 12 Gy (V12Gy), were calculated for each target. The distribution of V12Gy per target was plotted as a function of the target volume. For multi-target VMAT plans, the number of targets being treated in the same plan and the distance between targets were calculated to evaluate their impact on V12Gy. VMAT plans that had a large deviation of V12Gy from the average level were re-optimized to determine the possibility of reducing the variation of V12Gy in VMAT planning. Results Conformity index of multi-target VMAT plans were lower than that of DCA plans while the mean values of 12 Gy were comparable. The V12Gy for a target in VMAT plan did not show apparent dependence on the total number of targets or the distance between targets. The distribution of V12Gy exhibited a larger variation in VMAT plans compared to DCA plans. Re-optimization of outlier plans reduced V12 Gy by 33.9% and resulted in the V12Gy distribution in VMAT plans more closely resembling that of DCA plans. Conclusion The benchmark data on key plan quality metrics were established for single-isocenter multi-target SRS planning. It is feasible to use this knowledge to guide VMAT planning and reduce high V12Gy outliers.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 50 条
  • [1] Variation in Normal Brain Sparing in Stereotactic Radiosurgery Plans Treating Multiple Targets Using Single-Isocenter Volumetric Modulated Arc Therapy
    Cui, Y.
    Gao, H.
    Kirkpatrick, J.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E191 - E191
  • [2] Overcoming Problems Caused by Offset Distance of Multiple Targets in Single-isocenter Volumetric Modulated Arc Therapy Planning for Stereotactic Radiosurgery
    Ito, Takaaki
    Kubo, Kazuki
    Monzen, Hajime
    Yanagi, Yuya
    Nakamura, Kenji
    Sakai, Yusuke
    Nishimura, Yasumasa
    [J]. JOURNAL OF MEDICAL PHYSICS, 2023, 48 (04) : 365 - 372
  • [3] Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targets
    Stanhope, Carl
    Chang, Zheng
    Wang, Zhiheng
    Yin, Fang-Fang
    Kim, Grace
    Salama, Joseph K.
    Kirkpatrick, John
    Adamson, Justus
    [J]. PRACTICAL RADIATION ONCOLOGY, 2016, 6 (03) : 207 - 213
  • [4] Physics Considerations for Single-Isocenter Volumetric Modulated Arc Radiosurgery for Treatment of Multiple Intracranial Targets
    Stanhope, C.
    Chang, Z.
    Wang, Z.
    Yin, F.
    Kim, G.
    Salama, J.
    Kirkpatrick, J.
    Adamson, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3477 - 3477
  • [5] Treatment of Multiple Brain Metastases Using Stereotactic Radiosurgery with Single-Isocenter Volumetric Modulated Arc Therapy: Comparison with Conventional Dynamic Conformal Arc and Static Beam Stereotactic Radiosurgery
    Huang, C.
    Ren, L.
    Kirkpatrick, J.
    Wang, Z.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3854 - 3854
  • [6] Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases
    Lau, Steven K. M.
    Zakeri, Kaveh
    Zhao, Xiao
    Carmona, Ruben
    Knipprath, Erik
    Simpson, Daniel R.
    Nath, Sameer K.
    Kim, Gwe-Ya
    Sanghvi, Parag
    Hattangadi-Gluth, Jona A.
    Chen, Clark C.
    Murphy, Kevin T.
    [J]. NEUROSURGERY, 2015, 77 (02) : 233 - 240
  • [7] Single-Isocenter, Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases in a Single Session
    Knuthson, A. R.
    Widdel, L.
    Dial, C.
    Petit, J. H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E267 - E267
  • [8] Plan Quality and Delivery Time Comparison of Single-Isocenter Volumetric Modulated Arc Therapy Versus Stereotactic Radiosurgery for Brain Metastases
    Henke, L. E.
    Kashani, R.
    Abraham, C. D., Sr.
    Huang, J.
    Tsien, C.
    Dowling, J.
    Rich, K.
    Knutson, N.
    Robinson, C. G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E521 - E522
  • [9] Frame-based radiosurgery of multiple metastases using single-isocenter volumetric modulated arc therapy technique
    Ahn, Kang-Hyun
    Yenice, Kamil M.
    Koshy, Matthew
    Slavin, Konstantin, V
    Aydogan, Bulent
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 21 - 28
  • [10] FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES
    Clark, Grant M.
    Popple, Richard A.
    Young, P. Edward
    Fiveash, John B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01): : 296 - 302