FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES

被引:211
|
作者
Clark, Grant M. [1 ,2 ]
Popple, Richard A. [1 ]
Young, P. Edward [1 ]
Fiveash, John B. [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Ctr Comprehens Canc, Birmingham, AL 35249 USA
[2] W Virginia Univ, Sch Med, Morgantown, WV 26506 USA
关键词
Brain; metastases; volumetric modulated arc therapy; VMAT; radiosurgery; RapidArc; GAMMA-KNIFE RADIOSURGERY; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; CONFORMITY; IMRT;
D O I
10.1016/j.ijrobp.2009.05.029
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the relative plan quality of single-isocenter vs. multi-isocenter volumetric modulated arc therapy (VMAT) for radiosurgical treatment of multiple central nervous system metastases. Methods and Materials: VMAT plans were created using RapidArc technology for treatment of simulated patients with three brain metastases. The plans consisted of single-arc/single-isocenter, triple-arc (noncoplanar)/single-isocenter, and triple-arc (coplanar)/triple-isocenter configurations. All VMAT plans were normalized to deliver 100% of the 20-Gy prescription dose to all lesions. The plans were evaluated by calculation of Paddick and Radiation Therapy Oncology Group conformity index scores, Paddick gradient index scores, and 12-Gy isodose volumes. Results: All plans were judged clinically acceptable, but differences were observed in the dosimetric parameters, with the use of multiple noncoplanar arcs showing small improvements in the conformity indexes compared with the single-arc/single-isocenter and triple-arc (coplanar)/triple-isocenter plans. Multiple arc plans (triple-arc [noncoplanar]/single-isocenter and triple-arc [coplanar]/triple-isocenter) showed smaller 12-Gy isodose volumes in scenarios involving three metastases spaced closely together, with only small differences noted among all plans involving lesions spaced further apart. Conclusion: Our initial results suggest that single-isocenter VMAT plans can be used to deliver conformity equivalent to that of multiple isocenter VMAT techniques. For targets that are closely spaced, multiple noncoplanar single-isocenter arcs might be required. VMAT radiosurgery for multiple targets using a single isocenter can be efficiently delivered, requiring less than one-half the beam time required for multiple isocenter set ups. VMAT radiosurgery will likely replace multi-isocenter techniques for linear accelerator-based treatment of multiple targets. (C) 2010 Elsevier Inc.
引用
收藏
页码:296 / 302
页数:7
相关论文
共 50 条
  • [1] Single-Isocenter, Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases in a Single Session
    Knuthson, A. R.
    Widdel, L.
    Dial, C.
    Petit, J. H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E267 - E267
  • [2] Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases
    Lau, Steven K. M.
    Zakeri, Kaveh
    Zhao, Xiao
    Carmona, Ruben
    Knipprath, Erik
    Simpson, Daniel R.
    Nath, Sameer K.
    Kim, Gwe-Ya
    Sanghvi, Parag
    Hattangadi-Gluth, Jona A.
    Chen, Clark C.
    Murphy, Kevin T.
    [J]. NEUROSURGERY, 2015, 77 (02) : 233 - 240
  • [3] Single Isocenter Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases
    Chang-Halpenny, C. N.
    Rahimian, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E582 - E583
  • [5] Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single-Isocenter Volumetric Modulated Arc Therapy
    Wu, Qixue
    Snyder, Karen Chin
    Liu, Chang
    Huang, Yimei
    Zhao, Bo
    Chetty, Indrin J.
    Wen, Ning
    [J]. SCIENTIFIC REPORTS, 2016, 6
  • [6] Dosimetric Evaluation On Single-Isocenter Versus Multiple-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Simultaneous Treatment of Multiple Intracranial Metastases
    Huang, Z.
    Feng, Y.
    Luo, C.
    Liu, T.
    Zhu, D.
    Lo, S.
    Mayr, N.
    Yuh, W.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E651 - E651
  • [7] Physics Considerations for Single-Isocenter Volumetric Modulated Arc Radiosurgery for Treatment of Multiple Intracranial Targets
    Stanhope, C.
    Chang, Z.
    Wang, Z.
    Yin, F.
    Kim, G.
    Salama, J.
    Kirkpatrick, J.
    Adamson, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3477 - 3477
  • [8] Physics considerations for single-isocenter, volumetric modulated arc radiosurgery for treatment of multiple intracranial targets
    Stanhope, Carl
    Chang, Zheng
    Wang, Zhiheng
    Yin, Fang-Fang
    Kim, Grace
    Salama, Joseph K.
    Kirkpatrick, John
    Adamson, Justus
    [J]. PRACTICAL RADIATION ONCOLOGY, 2016, 6 (03) : 207 - 213
  • [9] Single Isocenter Radiosurgery for the Simultaneous Treatment of Multiple Brain Metastases: Volumetric Modulated Arc Therapy Or Dynamic Conformal Arc?
    Maurer, J.
    Sintay, B.
    Manning, M.
    Wiant, D.
    Liu, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3580 - 3580
  • [10] Frame-based radiosurgery of multiple metastases using single-isocenter volumetric modulated arc therapy technique
    Ahn, Kang-Hyun
    Yenice, Kamil M.
    Koshy, Matthew
    Slavin, Konstantin, V
    Aydogan, Bulent
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 21 - 28