Using a fixed-jaw technique to achieve superior delivery accuracy and plan quality in single-isocenter multiple-target stereotactic radiosurgery for brain metastases

被引:3
|
作者
Lai, Jialu [1 ,2 ]
Liu, Shoupeng [1 ,2 ]
Liu, Jia [3 ]
Jia, Yuming [4 ]
Lei, Kaijian [4 ]
Li, An [1 ,2 ]
Deng, Zhonghua [1 ,2 ]
Li, Bin [1 ,2 ]
Wang, Haitao [1 ,2 ]
Zhou, Lin [2 ,5 ]
机构
[1] Sichuan Univ, West China Hosp, Canc Ctr, Dept Radiotherapy, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, State Key Lab Biotherapy, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
[3] Chengdu First People Hosp, Dept Oncol, Chengdu 610041, Sichuan, Peoples R China
[4] Yibin Second People Hosp, Dept Oncol, Yibin 644000, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp, Canc Ctr, Dept Thorac Oncol, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Minimum dynamic leaf gap; Delivery accuracy; Plan quality; Multiple brain metastases; Fixed-jaw technique; MODULATED ARC THERAPY; MULTILEAF COLLIMATOR; RADIATION-THERAPY; TUMORS; WIDTH;
D O I
10.1016/j.jrras.2022.05.003
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To quantify the influence of the minimum dynamic leaf gap (DLG) on delivery accuracy and plan quality and determine whether the fixed-jaw technique can be used to reduce the adverse effects of DLG in single-isocenter volumetric modulated arc therapy (VMAT) stereotactic radiosurgery (SRS) for multiple brain metastases (BMs). Twelve patients, each with two BMs, were enrolled in this study. For each patient, five simulated cases were generated by adjusting the intertarget distance (ITD; range, 1???5 cm). For each case, two single-isocenter VMAT SRS plans with and without the fixed-jaw technique were designed. For the plan without the fixed-jaw technique, the jaw positions were automatically set to cover two targets (AJ-VMAT). For the other plan, the jaw was fixed to cover one lesion when another lesion was irradiated (FJ-VMAT). Dosimetric parameters and delivery parameters of two plans were compared. FJ-VMAT plans achieved similar target conformity, lower dose spillages (V10%, V25%), and lower normal brain tissue (NBT) mean dose, and better gradient index than AJ-VMAT plans regardless of ITD but with more monitor units and longer beam-on time (P 0.05). For ITD 0.05), especially for larger ITDs ( 2 cm) and tighter criteria (2%/1 mm) with a 4% improvement. Compared to conventional AJ-VMAT, FJ-VMAT could reduce the adverse effects from minimum DLG with superior delivery accuracy and plan quality in single-isocenter VMAT SRS for multiple BMs.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [1] Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage
    Roper, Justin
    Chanyavanich, Vorakarn
    Betzel, Gregory
    Switchenko, Jeffrey
    Dhabaan, Anees
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : 540 - 546
  • [2] Comparison of Planning Techniques for Single-Isocenter Multiple-Target Stereotactic Radiosurgery
    Ballesio, A.
    Wang, Z.
    MEDICAL PHYSICS, 2019, 46 (06) : E657 - E657
  • [3] Selection of single-isocenter for multiple-target stereotactic brain radiosurgery to minimize total margin volume
    Slagowski, Jordan M.
    Wen, Zhifei
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (18):
  • [4] Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases
    Nakano, Hisashi
    Tanabe, Satoshi
    Utsunomiya, Satoru
    Yamada, Takumi
    Sasamoto, Ryuta
    Nakano, Toshimichi
    Saito, Hirotake
    Takizawa, Takeshi
    Sakai, Hironori
    Ohta, Atsushi
    Abe, Eisuke
    Kaidu, Motoki
    Aoyama, Hidefumi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 155 - 165
  • [5] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Raza, Giorgio Hamid
    Capone, Luca
    Tini, Paolo
    Giraffa, Martina
    Gentile, Piercarlo
    Minniti, Giuseppe
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [6] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Giorgio Hamid Raza
    Luca Capone
    Paolo Tini
    Martina Giraffa
    Piercarlo Gentile
    Giuseppe Minniti
    Radiation Oncology, 17
  • [7] Stereotactic radiosurgery with single-isocenter dynamic arc therapy of multiple brain metastases
    Bodensohn, R.
    Kaempfel, A.
    Fleischmann, D. F.
    Hofmaier, J.
    Hadi, I.
    Garny, S.
    Reiner, M.
    Corradini, S.
    Forbrig, R.
    Thon, N.
    Belka, C.
    Niyazi, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S470 - S471
  • [8] Plan Quality and Delivery Time Comparison of Single-Isocenter Volumetric Modulated Arc Therapy Versus Stereotactic Radiosurgery for Brain Metastases
    Henke, L. E.
    Kashani, R.
    Abraham, C. D., Sr.
    Huang, J.
    Tsien, C.
    Dowling, J.
    Rich, K.
    Knutson, N.
    Robinson, C. G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E521 - E522
  • [9] Investigation of Plan Quality Metrics for Multiple-Metastases Using Single-Isocenter Radiosurgery Technique with Millennium MLC
    Flores-Martinez, E.
    Kim, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E804 - E804
  • [10] Single-Isocenter Multitarget Stereotactic Radiosurgery Is Safe and Effective in the Treatment of Multiple Brain Metastases
    Palmer, Joshua D.
    Sebastian, Nikhil T.
    Chu, Jacquline
    DiCostanzo, Dominic
    Bell, Erica H.
    Grecula, John
    Arnett, Andrea
    Blakaj, Dukagjin M.
    McGregor, John
    Elder, James B.
    Lu, Lanchun
    Zoller, Wesley
    Addington, Mark
    Lonser, Russell
    Chakravarti, Arnab
    Brown, Paul D.
    Raval, Raju