Selection of single-isocenter for multiple-target stereotactic brain radiosurgery to minimize total margin volume

被引:11
|
作者
Slagowski, Jordan M. [1 ,2 ]
Wen, Zhifei [2 ]
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 18期
关键词
stereotactic radiosurgery; single isocenter multiple target; treatment margins; CLINICAL-EVALUATION; RADIOTHERAPY; METASTASES; ACCURACY; SYSTEM;
D O I
10.1088/1361-6560/ab9703
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Treating multiple brain metastases with a single isocenter improves efficiency but requires margins to account for rotation induced shifts that increase with target-to-isocenter distance. A method to select the single isocenter position that minimizes the total volume of normal tissue treated during multi-target stereotactic radiosurgery (SRS) is presented. A statistical framework was developed to quantify the impact of uncertainties on planning target volumes (PTV). Translational and rotational shifts were modeled with independent, zero mean, Gaussian distributions in three dimensions added in quadrature. The standard deviations of errors were varied from 0.5-2.0 mm and 0.5 degrees-2.0 degrees. The volume of normal tissue treated due to margin expansions required to maintain a 95% probability of target coverage was computed. Tumors were modeled as 4-40 mm diameter spheres. Target separation distance was varied from 40-100 mm for two- and three-lesion scenarios. The percent increase in PTV was determined relative to an isocenter at the geometric centroid of the targets for the optimal isocenter that minimized the total normal tissue treated, and isocenters at the center-of-mass (COM) and center-of-surface-area (CSA). For two targets, isocenter placement at the optimal location, COM, and CSA, reduced the total margin versus an isocenter at midline up to 17.8%, 17.7%, and 17.8%, respectively, for 0.5 mm and 0.5 degrees errors. For three targets, optimal isocenter placement reduced the margin volume up to 21%, 19%, and 14%, for uncertainties of (0.5 mm, 0.5 degrees), (1.0 mm, 1.0 degrees), and (2.0 mm, 2.0 degrees), respectively. COM and CSA provide useful approximations to select the optimal isocenter for multi-target single-isocenter SRS for two or three targets with maximum dimensions 40 mm and separation distances 100 mm when uncertainties are 1.0 mm and 1.0 degrees. CSA provides a more accurate approximation than COM. Optimal treatment isocenter selection for multiple targets of large size differences can significantly reduce total margin volume.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Comparison of Planning Techniques for Single-Isocenter Multiple-Target Stereotactic Radiosurgery
    Ballesio, A.
    Wang, Z.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E657 - E657
  • [2] Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage
    Roper, Justin
    Chanyavanich, Vorakarn
    Betzel, Gregory
    Switchenko, Jeffrey
    Dhabaan, Anees
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : 540 - 546
  • [3] Innovative margin design and optimized isocenter to minimize the normal tissue in target volumes for single-isocenter multi-target stereotactic radiosurgery
    Yock, Adam D.
    Grees, Beshoi
    Luo, Guozhen
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (19):
  • [4] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Giorgio Hamid Raza
    Luca Capone
    Paolo Tini
    Martina Giraffa
    Piercarlo Gentile
    Giuseppe Minniti
    [J]. Radiation Oncology, 17
  • [5] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Raza, Giorgio Hamid
    Capone, Luca
    Tini, Paolo
    Giraffa, Martina
    Gentile, Piercarlo
    Minniti, Giuseppe
    [J]. RADIATION ONCOLOGY, 2022, 17 (01)
  • [6] Optimization of isocenter position for multiple brain metastases single-isocenter stereotactic radiosurgery to minimize dosimetric variations due to rotational uncertainty
    Shen, Zhenjiong
    wang, Hao
    Shao, Yan
    Duan, Yanhua
    Gu, Hengle
    Chen, Hua
    Feng, Aihui
    Huang, Ying
    Xu, Zhiyong
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 111
  • [7] Validation of virtual water phantom software for pre-treatment verification of single-isocenter multiple-target stereotactic radiosurgery
    Calvo-Ortega, Juan-Francisco
    Greer, Peter B.
    Hermida-Lopez, Marcelino
    Moragues-Femenia, Sandra
    Laosa-Bello, Coral
    Casals-Farran, Joan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 241 - 252
  • [8] Selection of Single Isocenter for Multi-Target Brain Treatment to Minimize Total Margin
    Slagowski, J. M.
    Wen, Z.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E393 - E393
  • [9] A Simplified and Accurate Off-Axis Winston-Lutz Method for Single-Isocenter Multiple-Target Stereotactic Radiosurgery
    Eagle, A.
    Tallhamer, M.
    Keener, J.
    Geneser, S.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E400 - E401
  • [10] Stereotactic radiosurgery with single-isocenter dynamic arc therapy of multiple brain metastases
    Bodensohn, R.
    Kaempfel, A.
    Fleischmann, D. F.
    Hofmaier, J.
    Hadi, I.
    Garny, S.
    Reiner, M.
    Corradini, S.
    Forbrig, R.
    Thon, N.
    Belka, C.
    Niyazi, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S470 - S471