Using a fixed-jaw technique to achieve superior delivery accuracy and plan quality in single-isocenter multiple-target stereotactic radiosurgery for brain metastases

被引:3
|
作者
Lai, Jialu [1 ,2 ]
Liu, Shoupeng [1 ,2 ]
Liu, Jia [3 ]
Jia, Yuming [4 ]
Lei, Kaijian [4 ]
Li, An [1 ,2 ]
Deng, Zhonghua [1 ,2 ]
Li, Bin [1 ,2 ]
Wang, Haitao [1 ,2 ]
Zhou, Lin [2 ,5 ]
机构
[1] Sichuan Univ, West China Hosp, Canc Ctr, Dept Radiotherapy, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, State Key Lab Biotherapy, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
[3] Chengdu First People Hosp, Dept Oncol, Chengdu 610041, Sichuan, Peoples R China
[4] Yibin Second People Hosp, Dept Oncol, Yibin 644000, Sichuan, Peoples R China
[5] Sichuan Univ, West China Hosp, Canc Ctr, Dept Thorac Oncol, 37 Guoxue Lane, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Minimum dynamic leaf gap; Delivery accuracy; Plan quality; Multiple brain metastases; Fixed-jaw technique; MODULATED ARC THERAPY; MULTILEAF COLLIMATOR; RADIATION-THERAPY; TUMORS; WIDTH;
D O I
10.1016/j.jrras.2022.05.003
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To quantify the influence of the minimum dynamic leaf gap (DLG) on delivery accuracy and plan quality and determine whether the fixed-jaw technique can be used to reduce the adverse effects of DLG in single-isocenter volumetric modulated arc therapy (VMAT) stereotactic radiosurgery (SRS) for multiple brain metastases (BMs). Twelve patients, each with two BMs, were enrolled in this study. For each patient, five simulated cases were generated by adjusting the intertarget distance (ITD; range, 1???5 cm). For each case, two single-isocenter VMAT SRS plans with and without the fixed-jaw technique were designed. For the plan without the fixed-jaw technique, the jaw positions were automatically set to cover two targets (AJ-VMAT). For the other plan, the jaw was fixed to cover one lesion when another lesion was irradiated (FJ-VMAT). Dosimetric parameters and delivery parameters of two plans were compared. FJ-VMAT plans achieved similar target conformity, lower dose spillages (V10%, V25%), and lower normal brain tissue (NBT) mean dose, and better gradient index than AJ-VMAT plans regardless of ITD but with more monitor units and longer beam-on time (P 0.05). For ITD 0.05), especially for larger ITDs ( 2 cm) and tighter criteria (2%/1 mm) with a 4% improvement. Compared to conventional AJ-VMAT, FJ-VMAT could reduce the adverse effects from minimum DLG with superior delivery accuracy and plan quality in single-isocenter VMAT SRS for multiple BMs.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [31] Rotational Corrections for Stereotactic Radiosurgery (SRS) of Multiple Brain Metastases Treated With Single Isocenter Technique
    Wang, Z.
    Kirkpatrick, J. P.
    Kim, G. J.
    Kelsey, C. R.
    Yin, F. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E602 - E602
  • [32] Effect of the Rotational Error On the Dose Distribution with Single-Isocenter Technique of Stereotactic Radiotherapy for Multiple Brain Metastases
    Nakano, H.
    Tanabe, S.
    Utsunomiya, S.
    Takizawa, T.
    Yamada, T.
    Sakai, H.
    Aoyama, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E652 - E652
  • [33] Quality Assurance of Multiple Brain Metastases with a Single-Isocenter Plan using Portal Dosimetry and Independent Dose Calculation
    Tanabe, M.
    Wakai, N.
    Murakami, J.
    Ikeguchi, T.
    Kitamoto, M.
    Nakano, T.
    Yoshimine, T.
    Tamamoto, T.
    Hasegawa, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E561 - E562
  • [34] SINGLE-ISOCENTER FRAMELESS INTENSITY-MODULATED STEREOTACTIC RADIOSURGERY FOR SIMULTANEOUS TREATMENT OF MULTIPLE BRAIN METASTASES: CLINICAL EXPERIENCE
    Nath, Sameer K.
    Lawson, Joshua D.
    Simpson, Daniel R.
    VanderSpek, Lauren
    Wang, Jia-Zhu
    Alksne, John F.
    Ciacci, Joseph
    Mundt, Arno J.
    Murphy, Kevin T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 91 - 97
  • [35] Simultaneous stereotactic radiosurgery of multiple brain metastases using single-isocenter dynamic conformal arc therapy: a prospective monocentric registry trial
    Raphael Bodensohn
    Anna-Lena Kaempfel
    Daniel Felix Fleischmann
    Indrawati Hadi
    Jan Hofmaier
    Sylvia Garny
    Michael Reiner
    Robert Forbrig
    Stefanie Corradini
    Niklas Thon
    Claus Belka
    Maximilian Niyazi
    Strahlentherapie und Onkologie, 2021, 197 : 601 - 613
  • [36] Simultaneous stereotactic radiosurgery of multiple brain metastases using single-isocenter dynamic conformal arc therapy: a prospective monocentric registry trial
    Bodensohn, Raphael
    Kaempfel, Anna-Lena
    Fleischmann, Daniel Felix
    Hadi, Indrawati
    Hofmaier, Jan
    Garny, Sylvia
    Reiner, Michael
    Forbrig, Robert
    Corradini, Stefanie
    Thon, Niklas
    Belka, Claus
    Niyazi, Maximilian
    STRAHLENTHERAPIE UND ONKOLOGIE, 2021, 197 (07) : 601 - 613
  • [37] Dynamic conformal arcs-based single-isocenter VMAT planning technique for radiosurgery of multiple brain metastases
    Pokhrel, Damodar
    Palmiero, Allison N.
    Bernard, Mark E.
    St Clair, William
    MEDICAL DOSIMETRY, 2021, 46 (02) : 195 - 200
  • [38] Dosimetry study comparing single-isocenter high-definition dynamic radiosurgery with multiple-isocenter cone-based stereotactic radiosurgery in treating multiple brain metastases
    Ji, Tianlong
    Li, Guang
    Song, Yaowen
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (03)
  • [39] Time-Driven Activity-Based Costing Comparison of Stereotactic Radiosurgery to Multiple Brain Lesions Using Single-Isocenter Versus Multiple-Isocenter Technique
    Parikh, Neil R.
    Kundu, Palak
    Levin-Epstein, Rebecca
    Chang, Eric M.
    Agazaryan, Nzhde
    Hegde, John, V
    Steinberg, Michael L.
    Tenn, Stephen E.
    Kaprealian, Tania B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (04): : 999 - 1007
  • [40] Determining Institutional Plan Quality Metrics for Intracranial Stereotactic Radiosurgery (SRS) for Single-Isocenter Multi-Target (SIMT) Treatments
    Taylor, W.
    Zoller, W.
    Addington, M.
    Palmer, J.
    Raval, R.
    Sebastian, N.
    DiCostanzo, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E266 - E266