Lateral flow immunostrips for the sensitive and rapid determination of 8-hydroxy-2′-deoxyguanosine using upconversion nanoparticles

被引:0
|
作者
Nengying Wu
Yuxi Wei
Lanlan Pan
Xiaolin Yang
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering
来源
Microchimica Acta | 2020年 / 187卷
关键词
Point of care testing; Lateral flow strip; Immunoassay; 8-Hydroxy-2′-deoxyguanosine; Upconversion nanoparticles;
D O I
暂无
中图分类号
学科分类号
摘要
Lateral flow immunostrips were newly designed and a sensitive and rapid fluorometric method for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) as a model target of small biomarker molecules was developed. The upconversion nanoparticles (UCNPs, NaYF4:Yb/Er core, and polyacrylic acid (PAA)-modified shell, size ~ 39 nm, excitation wavelength = 980 nm; emission wavelength = 540 nm) were employed as fluorescence signal material. The 8-OHdG antibody (Ab) was taken as the recognition probe while UCNP-labeled Ab was taken as the signal probe. Bovine serum albumin (BSA) was designed as carrier protein for 8-OHdG to form 8-OHdG-BSA conjugate as the capture probe. The lateral flow immunostrips were prepared by laminating a sample pad (glass fiber membrane), a test pad (nitrocellulose membrane), and adsorption pad (filter paper) on PVP backing. The capture probe was immobilized on the test zone while an IgG antibody taken as the control probe was immobilized on the control zone. When the signal probe and the sample were in sequence loaded on the sample pad, 8-OHdG analyte bound with the signal probe, and then the excess of the signal probe move along the strip and is collected by the capture probe on the test zone while the remnant signal probe is collected by the control probe on the control zone. The signal probe and capture probe were synthesized and characterized. The fluorescence intensity on the test zone was inversely proportional to the concentration of 8-OHdG for the quantitative determination while the fluorescence emission on the control zone was observed to validate the assay. The developed method showed a wide linear range from 0.10 to 10 nM, a quite low detection limit of 0.05 nM, small sample volume requirement (100 μL), short assay time (15 min), and good method reproducibility (RSD = 4.4%, nine immunostrips).
引用
收藏
相关论文
共 50 条
  • [31] Determination of 8-Hydroxy-2′-deoxyguanosine in Urine by Liquid Chromatography–Electrospray Ionization–Mass Spectrometry
    Hiroshi Moriwaki
    Analytical Sciences, 2000, 16 : 105 - 106
  • [32] An electrochemical aptasensor for the highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on the hybridization chain reaction
    Jia, Li-Ping
    Wang, Li-Juan
    Ma, Rong-Na
    Shang, Lei
    Zhang, Wei
    Xue, Qing-Wang
    Wang, Huai-Sheng
    TALANTA, 2018, 179 : 414 - 419
  • [33] 8-Hydroxy-2′-deoxyguanosine expression predicts hepatocellular carcinoma outcome
    Li, Shengmian
    Wang, Xiaoling
    Wui, Yijuan
    Zhang, Huijing
    Zhang, Lan
    Wang, Cuiju
    Zhang, Ruixing
    Guo, Zhanjun
    ONCOLOGY LETTERS, 2012, 3 (02) : 338 - 342
  • [34] Quantitative determination of 8-hydroxy-2′-deoxyguanosine as a biomarker of oxidative stress in thalassemic patients using HPLC with an electrochemical detector
    C. Matayatsuk
    P. Wilairat
    Journal of Analytical Chemistry, 2008, 63 : 52 - 56
  • [35] Quantitative determination of 8-hydroxy-2'-deoxyguanosine as a biomarker of oxidative stress in thalassemic patients using HPLC with an electrochemical detector
    Matayatsuk, C.
    Wilairat, P.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (01) : 52 - 56
  • [36] Urinary 8-hydroxy-2′-deoxyguanosine:: a biomarker of environmental oxidative stress?
    Sajous, L.
    Botta, A.
    Sari-Minodier, I.
    ANNALES DE BIOLOGIE CLINIQUE, 2008, 66 (01) : 19 - 29
  • [37] Determination of urinary 8-hydroxy-2′-deoxyguanosine (8-OHdG) in workers exposed to diesel particulate exhaust
    Savela, K
    Svoboda, R
    Mori, T
    Harri, M
    Kasai, H
    FREE RADICAL BIOLOGY AND MEDICINE, 2004, 36 : S83 - S83
  • [38] Increased serum levels of 8-hydroxy-2′-deoxyguanosine in clinical depression
    Forlenza, MJ
    Miller, GE
    PSYCHOSOMATIC MEDICINE, 2006, 68 (01): : 1 - 7
  • [39] Methodological considerations and factors affecting 8-hydroxy-2′-deoxyguanosine analysis
    Möller, L
    Hofer, T
    Zeisig, M
    FREE RADICAL RESEARCH, 1998, 29 (06) : 511 - 524
  • [40] Increased serum levels of 8-hydroxy-2′-deoxyguanosine in clinical depression
    Forlenza, MJ
    Miller, GE
    CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2004, 13 (11) : 1857S - 1857S