An electrochemical aptasensor for the highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on the hybridization chain reaction

被引:29
|
作者
Jia, Li-Ping [1 ]
Wang, Li-Juan [1 ]
Ma, Rong-Na [1 ]
Shang, Lei [1 ]
Zhang, Wei [1 ]
Xue, Qing-Wang [1 ]
Wang, Huai-Sheng [1 ]
机构
[1] Liaocheng Univ, Dept Chem, Liaocheng 252000, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
8-Hydroxy-2 '-deoxyguanosin; G-quadruplex; Hybridization chain reaction; Electrochemical aptasensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; ENZYME-FREE; LABEL-FREE; ULTRASENSITIVE DETECTION; GOLD NANOPARTICLES; MICRORNA DETECTION; NUCLEIC-ACIDS; AMPLIFICATION; APTAMER;
D O I
10.1016/j.talanta.2017.11.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work a highly sensitive and selective aptasensor was developed for the determination of 8-hydroxy-2'-deoxyguanosine (8-OH-dG) based on the hybridization chain reaction (HCR) signal amplification. It was observed that the aptamer of 8-OH-dG could hybridize with the capture DNA immobilized on the gold electrode with a sticky tail left, which initiated the HCR and led to the formation of extended dsDNA structure on the electrode surface. Then the electroactive species ([Ru(NH3)6](3+), RuHex) intercalated into the dsDNA grooves to generate the amplified signal. However, in the presence of 8-OH-dG, the aptamer containing G-rich nucleic acid sequences would be induced to form a G-quadruplex structure, which made it impossible to continue the HCR. So the detection signal will significantly decrease. Under the optimal conditions, the peak current of RuHex was linear with the logarithm of 8-OH-dG concentration in the range from 10 pM to 100 pM with the detection limit of 2.5 pM. By integrating the merits of enzyme-free amplification power of the HCR and the inherent high sensitivity of the electrochemical technique, the prepared aptasensor not only showed high sensitivity for the detection of 8-OH-dG, but also exhibited good selectivity against to the uric acid, an important interferent in the urine sample. Particularly, the aptasensor was applied to detect 8-OH-dG in urine samples with satisfactory results.
引用
收藏
页码:414 / 419
页数:6
相关论文
共 50 条
  • [1] A label-free electrochemical aptasensor for 8-hydroxy-2′-deoxyguanosine detection
    Shi, Shan-Shan
    Jia, Li-Ping
    Ma, Rong-Na
    Jia, Wen-Li
    Wang, Huai-Sheng
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 759 : 107 - 112
  • [2] A colorimetric aptasensor for the highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on G-quadruplex-hemin DNAzyme
    Liu, Hui
    Wang, Yong-Sheng
    Wang, Jia-Cheng
    Xue, Jin-Hua
    Zhou, Bin
    Zhao, Hui
    Liu, Shan-Du
    Tang, Xian
    Chen, Si-Han
    Li, Ming-Hui
    Cao, Jin-Xiu
    ANALYTICAL BIOCHEMISTRY, 2014, 458 : 4 - 10
  • [3] Detection of 8-hydroxy-2′deoxyadenosine and 8-hydroxy-2′deoxyguanosine by Avidin
    Hooley, Elizabeth
    Conners, Rebecca
    Brady, Leo
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C220 - C220
  • [4] Highly sensitive detection of lipopolysaccharides using an aptasensor based on hybridization chain reaction
    Xie, Peiyan
    Zhu, Longjiao
    Shao, Xiangli
    Huang, Kunlun
    Tian, Jingjing
    Xu, Wentao
    SCIENTIFIC REPORTS, 2016, 6
  • [5] Highly sensitive detection of lipopolysaccharides using an aptasensor based on hybridization chain reaction
    Peiyan Xie
    Longjiao Zhu
    Xiangli Shao
    Kunlun Huang
    Jingjing Tian
    Wentao Xu
    Scientific Reports, 6
  • [6] Highly Sensitive Chitosan and ZrO2 Nanoparticles-Based Electrochemical Sensor for 8-Hydroxy-2′-deoxyguanosine Determination
    Rong, Shengzhong
    Pan, Deng
    Li, Xuehui
    Gao, Mucong
    Yu, Hongwei
    Jiang, Jinghui
    Zhang, Ze
    Zeng, Dongdong
    Pan, Hongzhi
    Chang, Dong
    CURRENT ANALYTICAL CHEMISTRY, 2019, 15 (06) : 648 - 655
  • [7] THE DEVELOPMENT OF A SENSITIVE ANALYSIS FOR 8-HYDROXY-2'-DEOXYGUANOSINE
    FLOYD, RA
    FREE RADICAL RESEARCH COMMUNICATIONS, 1990, 8 (03): : 139 - 141
  • [8] Methodology for urinary 8-hydroxy-2′-deoxyguanosine analysis by HPLC with electrochemical detection
    de Martinis, BS
    Bianchi, MDLP
    PHARMACOLOGICAL RESEARCH, 2002, 46 (02) : 129 - 131
  • [9] Electrochemical Aptasensor based on the Hybridization Chain Reaction for Kanamycin Detection
    Zhang, Qinpu
    Li, Fang
    Li, Xinmiao
    Liu, Yunhong
    Han, Jing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (11): : 1 - 11
  • [10] A highly sensitive aptasensor for OTA detection based on hybridization chain reaction and fluorescent perylene probe
    Wang, Bin
    Wu, Yuanya
    Chen, Yanfen
    Weng, Bo
    Xu, Liqun
    Li, Changming
    BIOSENSORS & BIOELECTRONICS, 2016, 81 : 125 - 130