An electrochemical aptasensor for the highly sensitive detection of 8-hydroxy-2′-deoxyguanosine based on the hybridization chain reaction

被引:29
|
作者
Jia, Li-Ping [1 ]
Wang, Li-Juan [1 ]
Ma, Rong-Na [1 ]
Shang, Lei [1 ]
Zhang, Wei [1 ]
Xue, Qing-Wang [1 ]
Wang, Huai-Sheng [1 ]
机构
[1] Liaocheng Univ, Dept Chem, Liaocheng 252000, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
8-Hydroxy-2 '-deoxyguanosin; G-quadruplex; Hybridization chain reaction; Electrochemical aptasensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; ENZYME-FREE; LABEL-FREE; ULTRASENSITIVE DETECTION; GOLD NANOPARTICLES; MICRORNA DETECTION; NUCLEIC-ACIDS; AMPLIFICATION; APTAMER;
D O I
10.1016/j.talanta.2017.11.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work a highly sensitive and selective aptasensor was developed for the determination of 8-hydroxy-2'-deoxyguanosine (8-OH-dG) based on the hybridization chain reaction (HCR) signal amplification. It was observed that the aptamer of 8-OH-dG could hybridize with the capture DNA immobilized on the gold electrode with a sticky tail left, which initiated the HCR and led to the formation of extended dsDNA structure on the electrode surface. Then the electroactive species ([Ru(NH3)6](3+), RuHex) intercalated into the dsDNA grooves to generate the amplified signal. However, in the presence of 8-OH-dG, the aptamer containing G-rich nucleic acid sequences would be induced to form a G-quadruplex structure, which made it impossible to continue the HCR. So the detection signal will significantly decrease. Under the optimal conditions, the peak current of RuHex was linear with the logarithm of 8-OH-dG concentration in the range from 10 pM to 100 pM with the detection limit of 2.5 pM. By integrating the merits of enzyme-free amplification power of the HCR and the inherent high sensitivity of the electrochemical technique, the prepared aptasensor not only showed high sensitivity for the detection of 8-OH-dG, but also exhibited good selectivity against to the uric acid, an important interferent in the urine sample. Particularly, the aptasensor was applied to detect 8-OH-dG in urine samples with satisfactory results.
引用
收藏
页码:414 / 419
页数:6
相关论文
共 50 条
  • [31] Serum 8-hydroxy-2′-deoxyguanosine as a biomarker of diabetes
    Jun, Jiao
    Lou, Xudan
    Wang, Haidong
    Harms-Ringdahl, Mats
    Skog, Sven
    He, Ellen
    Haghdoost, Siamak
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2014, 30 : 7 - 8
  • [32] Facile synthesis of porous single-walled carbon nanotube for sensitive detection of 8-Hydroxy-2′-deoxyguanosine
    Shang, Tianyi
    Wang, Peilin
    Liu, Xiuhui
    Jiang, Xuechan
    Hu, Zhongai
    Lu, Xiaoquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 808 : 28 - 34
  • [33] A highly sensitive automated flow immunosensor based on kinetic exclusion analysis for determination of the cancer marker 8-hydroxy-2′-deoxyguanosine in urine
    Darwish, Ibrahim A.
    Wani, Tanveer A.
    Khalil, Nasr Y.
    Aboul-Fadl, Tarek
    Kadi, Adnan A.
    Al-Majed, Abdul-Rahman A.
    ANALYTICAL METHODS, 2013, 5 (06) : 1502 - 1509
  • [34] Urinary excretion of 8-hydroxy-2′-deoxyguanosine measured by high-performance liquid chromatography with electrochemical detection
    Pilger, A
    Ivancsits, S
    Germadnik, D
    Rüdiger, HW
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 393 - 401
  • [35] Assay for the determination of urinary 8-hydroxy-2'deoxyguanosine by high-performance liquid chromatography with electrochemical detection
    Germadnik, D
    Pilger, A
    Rudiger, HW
    JOURNAL OF CHROMATOGRAPHY B, 1997, 689 (02): : 399 - 403
  • [36] Fast Quantification of Salivary 8-Hydroxy-2′-deoxyguanosine as DNA Damage Biomarker Using CE with Electrochemical Detection
    Yueqing Guan
    Guobin Zhou
    Jiannong Ye
    Chromatographia, 2014, 77 : 603 - 607
  • [37] Ultrasmall HKUST-1 nanoparticles decorated graphite nanosheets for highly sensitive electrochemical sensing of DNA damage biomarker 8-hydroxy-2′-deoxyguanosine
    Cao, Guojun
    Wu, Can
    Tang, Yong
    Wan, Chidan
    ANALYTICA CHIMICA ACTA, 2019, 1058 : 80 - 88
  • [38] A novel fluorescence aptasensor for 8-hydroxy-2'-deoxyguanosine based on the conformational switching of K+-stabilized G-quadruplex
    Liu, Hui
    Wang, Yong-Sheng
    Tang, Xian
    Yang, Hui-Xian
    Chen, Si-Han
    Zhao, Hui
    Liu, Shan-Du
    Zhu, Yu-Feng
    Wang, Xiao-Feng
    Huang, Yan-Qin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 118 : 177 - 182
  • [39] An exonuclease-assisted amplification electrochemical aptasensor for Hg2+ detection based on hybridization chain reaction
    Bao, Ting
    Wen, Wei
    Zhang, Xiuhua
    Xia, Qinghua
    Wang, Shengfu
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 318 - 323
  • [40] An electrochemical aptasensor for highly sensitive detection of CEA based on exonuclease III and hybrid chain reaction dual signal amplification
    Niu, Cui
    Lin, Xiaojuan
    Jiang, Xin
    Guo, Fei
    Liu, Jianxiao
    Liu, Xiangqin
    Huang, Hongge
    Huang, Yu
    BIOELECTROCHEMISTRY, 2022, 143