Lateral flow immunostrips for the sensitive and rapid determination of 8-hydroxy-2′-deoxyguanosine using upconversion nanoparticles

被引:0
|
作者
Nengying Wu
Yuxi Wei
Lanlan Pan
Xiaolin Yang
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering
来源
Microchimica Acta | 2020年 / 187卷
关键词
Point of care testing; Lateral flow strip; Immunoassay; 8-Hydroxy-2′-deoxyguanosine; Upconversion nanoparticles;
D O I
暂无
中图分类号
学科分类号
摘要
Lateral flow immunostrips were newly designed and a sensitive and rapid fluorometric method for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) as a model target of small biomarker molecules was developed. The upconversion nanoparticles (UCNPs, NaYF4:Yb/Er core, and polyacrylic acid (PAA)-modified shell, size ~ 39 nm, excitation wavelength = 980 nm; emission wavelength = 540 nm) were employed as fluorescence signal material. The 8-OHdG antibody (Ab) was taken as the recognition probe while UCNP-labeled Ab was taken as the signal probe. Bovine serum albumin (BSA) was designed as carrier protein for 8-OHdG to form 8-OHdG-BSA conjugate as the capture probe. The lateral flow immunostrips were prepared by laminating a sample pad (glass fiber membrane), a test pad (nitrocellulose membrane), and adsorption pad (filter paper) on PVP backing. The capture probe was immobilized on the test zone while an IgG antibody taken as the control probe was immobilized on the control zone. When the signal probe and the sample were in sequence loaded on the sample pad, 8-OHdG analyte bound with the signal probe, and then the excess of the signal probe move along the strip and is collected by the capture probe on the test zone while the remnant signal probe is collected by the control probe on the control zone. The signal probe and capture probe were synthesized and characterized. The fluorescence intensity on the test zone was inversely proportional to the concentration of 8-OHdG for the quantitative determination while the fluorescence emission on the control zone was observed to validate the assay. The developed method showed a wide linear range from 0.10 to 10 nM, a quite low detection limit of 0.05 nM, small sample volume requirement (100 μL), short assay time (15 min), and good method reproducibility (RSD = 4.4%, nine immunostrips).
引用
收藏
相关论文
共 50 条
  • [21] STRUCTURAL AND CONFORMATIONAL-ANALYSES OF 8-HYDROXY-2'-DEOXYGUANOSINE
    CULP, SJ
    CHO, BP
    KADLUBAR, FF
    EVANS, FE
    CHEMICAL RESEARCH IN TOXICOLOGY, 1989, 2 (06) : 416 - 422
  • [22] Pattern recognition of 8-hydroxy-2′-deoxyguanosine in biological fluids
    Raluca-Ioana Stefan-van Staden
    Liliana-Roxana Balahura
    Livia Alexandra Gugoasa
    Jacobus F. van Staden
    Hassan Y. Aboul-Enein
    Marcela-Corina Rosu
    Stela Maria Pruneanu
    Analytical and Bioanalytical Chemistry, 2018, 410 : 115 - 121
  • [23] Increased testicular 8-hydroxy-2′-deoxyguanosine in patients with varicocele
    Ishikawa, Tomomoto
    Fujioka, Hitoshi
    Ishimura, Takeshi
    Takenaka, Atsushi
    Fujisawa, Masato
    BJU INTERNATIONAL, 2007, 100 (04) : 863 - 866
  • [24] 8-Hydroxy-2′-deoxyguanosine is a prognostic mediator for cardiac event
    Suzuki, Satoshi
    Shishido, Tetsuro
    Ishino, Mitsunori
    Katoh, Shigehiko
    Sasaki, Toshiki
    Nishiyama, Satoshi
    Miyashita, Takehiko
    Miyamoto, Takuya
    Nitobe, Joji
    Watanabe, Tetsu
    Takeishi, Yasuchika
    Kubota, Isao
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2011, 41 (07) : 759 - 766
  • [25] Pattern recognition of 8-hydroxy-2'-deoxyguanosine in biological fluids
    Stefan-van Staden, Raluca-Ioana
    Balahura, Liliana-Roxana
    Gugoasa, Livia Alexandra
    van Staden, Jacobus F.
    Aboul-Enein, Hassan Y.
    Rosu, Marcela-Corina
    Pruneanu, Stela Maria
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (01) : 115 - 121
  • [26] 8-Hydroxy-2′-Deoxyguanosine and Cardiovascular Disease: a Systematic Review
    Kroese, Lona J.
    Scheffer, Peter G.
    CURRENT ATHEROSCLEROSIS REPORTS, 2014, 16 (11) : 1 - 8
  • [27] 8-Hydroxy-2′-Deoxyguanosine and Cardiovascular Disease: a Systematic Review
    Lona J. Kroese
    Peter G. Scheffer
    Current Atherosclerosis Reports, 2014, 16
  • [28] Intranuclear distribution of 8-hydroxy-2′-deoxyguanosine:: An immunocytochemical study
    Toyokuni, S
    Iwasa, Y
    Kondo, S
    Tanaka, T
    Ochi, H
    Hiai, H
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1999, 47 (06) : 833 - 835
  • [29] DETERMINATION OF THE DNA DAMAGE LEVELS IN PATIENTS WITH CHRONIC RENAL FAILURE USING 8-HYDROXY-2′-DEOXYGUANOSINE BIOMARKER
    Aksoy, Aziz
    FRESENIUS ENVIRONMENTAL BULLETIN, 2018, 27 (12A): : 9308 - 9314
  • [30] Solution structure of a DNA duplex containing 8-hydroxy-2′-deoxyguanosine opposite deoxyguanosine
    Thiviyanathan, V
    Somasunderam, A
    Hazra, TK
    Mitra, S
    Gorenstein, DG
    JOURNAL OF MOLECULAR BIOLOGY, 2003, 325 (03) : 433 - 442