Lateral flow immunostrips for the sensitive and rapid determination of 8-hydroxy-2′-deoxyguanosine using upconversion nanoparticles

被引:0
|
作者
Nengying Wu
Yuxi Wei
Lanlan Pan
Xiaolin Yang
Honglan Qi
Qiang Gao
Chengxiao Zhang
机构
[1] Shaanxi Normal University,Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering
来源
Microchimica Acta | 2020年 / 187卷
关键词
Point of care testing; Lateral flow strip; Immunoassay; 8-Hydroxy-2′-deoxyguanosine; Upconversion nanoparticles;
D O I
暂无
中图分类号
学科分类号
摘要
Lateral flow immunostrips were newly designed and a sensitive and rapid fluorometric method for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) as a model target of small biomarker molecules was developed. The upconversion nanoparticles (UCNPs, NaYF4:Yb/Er core, and polyacrylic acid (PAA)-modified shell, size ~ 39 nm, excitation wavelength = 980 nm; emission wavelength = 540 nm) were employed as fluorescence signal material. The 8-OHdG antibody (Ab) was taken as the recognition probe while UCNP-labeled Ab was taken as the signal probe. Bovine serum albumin (BSA) was designed as carrier protein for 8-OHdG to form 8-OHdG-BSA conjugate as the capture probe. The lateral flow immunostrips were prepared by laminating a sample pad (glass fiber membrane), a test pad (nitrocellulose membrane), and adsorption pad (filter paper) on PVP backing. The capture probe was immobilized on the test zone while an IgG antibody taken as the control probe was immobilized on the control zone. When the signal probe and the sample were in sequence loaded on the sample pad, 8-OHdG analyte bound with the signal probe, and then the excess of the signal probe move along the strip and is collected by the capture probe on the test zone while the remnant signal probe is collected by the control probe on the control zone. The signal probe and capture probe were synthesized and characterized. The fluorescence intensity on the test zone was inversely proportional to the concentration of 8-OHdG for the quantitative determination while the fluorescence emission on the control zone was observed to validate the assay. The developed method showed a wide linear range from 0.10 to 10 nM, a quite low detection limit of 0.05 nM, small sample volume requirement (100 μL), short assay time (15 min), and good method reproducibility (RSD = 4.4%, nine immunostrips).
引用
收藏
相关论文
共 50 条
  • [11] Expression of 8-hydroxy-2'-deoxyguanosine in gastric carcinomas
    Xiaoyu Chena
    bDepartment of physiology
    The Journal of Biomedical Research, 2007, (01) : 11 - 14
  • [12] Elevated 8-hydroxy-2′- Deoxyguanosine in Patients with COPD
    Yang, S. F.
    Wu, J.
    Gao, X. L.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2014, 62 : S384 - S384
  • [13] Serum 8-hydroxy-2′-deoxyguanosine as a biomarker of diabetes
    Jun, Jiao
    Lou, Xudan
    Wang, Haidong
    Harms-Ringdahl, Mats
    Skog, Sven
    He, Ellen
    Haghdoost, Siamak
    DIABETES-METABOLISM RESEARCH AND REVIEWS, 2014, 30 : 7 - 8
  • [14] Determination of 8-hydroxy-2′-deoxyguanosine in untreated urine by capillary electrophoresis with UV detection
    Kvasnicová, V
    Samcová, E
    Jursová, A
    Jelínek, I
    JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) : 513 - 517
  • [15] Determination of urinary 8-hydroxy-2′-deoxyguanosine in obese patients by HPLC with electrochemical detection
    Samcová, E
    Marhol, P
    Opekar, F
    Langmaier, J
    ANALYTICA CHIMICA ACTA, 2004, 516 (1-2) : 107 - 110
  • [16] Highly Sensitive Electrochemical Sensor for the Determination of 8-Hydroxy-2′-deoxyguanosine Incorporating SWCNTs-Nafion Composite Film
    Yang, Lingfei
    Wang, Bing
    Qi, Honglan
    Gao, Qiang
    Li, Chen-zhong
    Zhang, Chengxiao
    JOURNAL OF SENSORS, 2015, 2015
  • [17] Electrochemical Determination of 8-Nitroguanine and 8-Hydroxy-2`-Deoxyguanosine in Urine and Whole Blood Using Stochastic Sensors
    Stefan-van Staden, Raluca-Ioana
    Balahura, Liliana-Roxana
    Aboul-Enein, Hassan Y.
    ANALYTICAL LETTERS, 2021, 54 (04) : 729 - 741
  • [18] 8-Hydroxy-2’-Deoxyguanosine as an Oxidative Stress Marker in Insomnia
    N. V. Semenova
    I. M. Madaeva
    A. S. Brichagina
    S. I. Kolesnikov
    L. I. Kolesnikova
    Bulletin of Experimental Biology and Medicine, 2021, 171 : 384 - 387
  • [19] 8-Hydroxy-2'-Deoxyguanosine as an Oxidative Stress Marker in Insomnia
    Semenova, N., V
    Madaeva, I. M.
    Brichagina, A. S.
    Kolesnikov, S., I
    Kolesnikova, L., I
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2021, 171 (03) : 384 - 387
  • [20] Author Response: Tear Levels of 8-hydroxy-2′-deoxyguanosine
    Haworth, Kristina
    Chandler, Heather
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (03) : 1588 - 1588