Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

被引:0
|
作者
Kazunori Hirasawa
Nobuyuki Shoji
Masayuki Kasahara
Kazuhiro Matsumura
Kimiya Shimizu
机构
[1] Orthoptics and Visual Science,Department of Rehabilitation
[2] School of Allied Health Sciences,Department of Ophthalmology
[3] Kitasato University,undefined
[4] School of Medicine,undefined
[5] Kitasato University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.
引用
收藏
相关论文
共 50 条
  • [41] Comparison Between 24-2 ZEST and 24-2 ZEST FAST Strategies in Glaucoma and Ocular Hypertension Using a Fundus Perimeter
    Romano, Dario
    Oddone, Francesco
    Montesano, Giovanni
    Fogagnolo, Paolo
    Colizzi, Benedetta
    Tanga, Lucia
    Giammaria, Sara
    Rui, Chiara
    Rossetti, Luca M.
    JOURNAL OF GLAUCOMA, 2024, 33 (03) : 162 - 167
  • [42] Octopus Standard Automated Perimetry, Pulsar Perimetry, Moorfields Motion Displacement Test and Heidelberg Retinal Tomography in Glaucoma Detection - A Comparison of Diagnostic Accuracy
    Oleszczuk, J. D.
    Bergin, C.
    Schnyder, C.
    Crabb, D.
    Sharkawi, E.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [43] Effect of yellow-tinted intraocular lens on standard automated perimetry and short wavelength automated perimetry in patients with glaucoma
    Nilforushan, Naveed
    Parsamanesh, Mohammad
    Yu, Fei
    Nassiri, Nariman
    Miraftabi, Arezoo
    Coleman, Anne L.
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2014, 21 (03) : 216 - 219
  • [44] Within-test variability of frequency-doubling perimetry using a 24-2 test pattern
    Spry, PGD
    Johnson, CA
    JOURNAL OF GLAUCOMA, 2002, 11 (04) : 315 - 320
  • [45] Repeatability and correlation of a virtual reality perimeter with standard automated perimetry in glaucoma patients
    Chaudhry, Anisa Fatima
    Berneshawi, Andrew Raphael
    Liu, Jocelyn
    Shue, Ann
    Chang, Dolly
    Kim, Julia
    Chang, Robert T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [46] Longitudinal Changes in the Useful Field of View and Standard Automated Perimetry in Patients with Glaucoma
    Vieira Lopes, Nara Lidia
    Gracitelli, Carolina Pelegrini
    Diniz-Filho, Alberto
    Paranhos, Augusto, Jr.
    Medeiros, Felipe A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [47] Comparison of Frequency Doubling Perimetry vs standard automated perimetry in glaucoma and age-related maculopathy.
    Kampmeier, JM
    Lang, GK
    Lang, GE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S87 - S87
  • [48] The Impacts of Face Mask Use on Standard Automated Perimetry Results in Glaucoma Patients
    Bayram, Nurettin
    Gundogan, Medine
    Ozsaygili, Cemal
    Vural, Esra
    Cicek, Ayse
    JOURNAL OF GLAUCOMA, 2021, 30 (04) : 287 - 292
  • [49] CORRELATION BETWEEN CONVENTION-AL AUTOMATED PERIMETRY (24-2 SITA)AND FREQUENCY-DOUBLING TECHNOLO-GY IN ADVANCED GLAUCOMA
    F.J.Munoz-Negrete
    J.Gonzalez Martin-Moro
    J.Lara
    G.Rebolleda
    国际眼科杂志, 2003, (01) : 14 - 14
  • [50] Comparison of conventional and pattern discrimination perimetry in a prospective study of glaucoma patients
    Ansari, I
    Chauhan, BC
    McCormick, TA
    LeBlanc, RP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (13) : 4150 - 4157