Comparison of size modulation and conventional standard automated perimetry with the 24-2 test protocol in glaucoma patients

被引:0
|
作者
Kazunori Hirasawa
Nobuyuki Shoji
Masayuki Kasahara
Kazuhiro Matsumura
Kimiya Shimizu
机构
[1] Orthoptics and Visual Science,Department of Rehabilitation
[2] School of Allied Health Sciences,Department of Ophthalmology
[3] Kitasato University,undefined
[4] School of Medicine,undefined
[5] Kitasato University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
This prospective randomized study compared test results of size modulation standard automated perimetry (SM-SAP) performed with the Octopus 600 and conventional SAP (C-SAP) performed with the Humphrey Field Analyzer (HFA) in glaucoma patients. Eighty-eight eyes of 88 glaucoma patients underwent SM-SAP and C-SAP tests with the Octopus 600 24-2 Dynamic and HFA 24-2 SITA-Standard, respectively. Fovea threshold, mean defect and square loss variance of SM-SAP were significantly correlated with the corresponding C-SAP indices (P < 0.001). The false-positive rate was slightly lower and false-negative rate slightly higher, with SM-SAP than C-SAP (P = 0.002). Point-wise threshold values obtained with SM-SAP were moderately to strongly correlated with those obtained with C-SAP (P < 0.001). The correlation coefficients of the central zone were significantly lower than those of the middle to peripheral zone (P = 0.031). The size and depth of the visual field (VF) defect were smaller (P = 0.039) and greater (P = 0.043), respectively, on SM-SAP than on C-SAP. Although small differences were observed in VF sensitivity in the central zone, the defect size and depth and the reliability indices between SM-SAP and C-SAP, global indices of the two testing modalities were well correlated.
引用
收藏
相关论文
共 50 条
  • [31] Comparison of frequency doubling perimetry and standard achromatic computerized perimetry in patients with glaucoma
    Stefan Serguhn
    Detlev Spiegel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2001, 239 : 351 - 355
  • [32] The Effect of Eccentricity on the Test-Retest Characteristics of Standard Automated Perimetry in Glaucoma
    Bishop, Sarah
    Ho, Yuan-Hao
    Goren, Deborah
    Flanagan, John
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [33] Comparison of 24-2 and 30-2 perimetry in glaucomatous and nonglaucomatous optic neuropathies
    Khoury, JM
    Donahue, SP
    Lavin, PJM
    Tsai, JC
    JOURNAL OF NEURO-OPHTHALMOLOGY, 1999, 19 (02) : 100 - 108
  • [34] Comparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression
    Hu, Rongrong
    Wang, Chenkun
    Gu, Yangshun
    Racette, Lyne
    MEDICINE, 2016, 95 (07) : e2618
  • [35] Repeatability of Automated OCT-based 24-2 Visual Threshold Estimationin Patients with Glaucoma
    Abramoff, Michael David
    Bogunovic, Hrvoje
    Kwon, Young H.
    Critser, Brice
    Garvin, Mona K.
    Sonka, Milan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [36] Interpretation of the Humphrey Matrix 24-2 test in the diagnosis of preperimetric glaucoma
    Jin A. Choi
    Na Young Lee
    Chan Kee Park
    Japanese Journal of Ophthalmology, 2009, 53 : 24 - 30
  • [37] Interpretation of the Humphrey Matrix 24-2 test in the diagnosis of preperimetric glaucoma
    Choi, Jin A.
    Lee, Na Young
    Park, Chan Kee
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (01) : 24 - 30
  • [38] Comparison of Three Visual Field Tests in Children: Frequency Doubling Test, 24-2 and 30-2 SITA Perimetry
    Han, Sangyoun
    Baek, Seung-Hee
    Kim, Ungsoo Samuel
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (05) : 647 - 650
  • [39] Frequency of occurrence of abnormal test points with HFA 24-2 and 10-2 in glaucoma patients
    Nomoto, Hiroki
    Matsumoto, Chota
    Okuyama, Sachiko
    Hashimoto, Shigeki
    Kayasawa, Tomoyasu
    Eura, Mariko
    Numata, Takuya
    Yamao, Sayaka
    Shimomura, Yoshikazu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [40] Smartphone Perimetry: Comparison to Standard Automated Perimetry and Assessment of Size-Modulation Strategy with Frequency-Of-Seeing Curves in Healthy Subjects
    Wijayagunaratne, Anushi
    Linton, Edward
    Franch, Ivan Marin
    Alawa, Karam
    Wall, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)